This variable area flow meter measures water flow from 6 to 60 GPH at ±6% accuracy. It has a 1/4" (6.3 mm) NPT Female connection rated to 125 psi (8.62 bar) and 130°F (54°C). It suits oem flow measurement and water flow measurement.
This variable area flow meter measures water flow from 6 to 60 GPH at ±6% accuracy. It has a 1/4" (6.3 mm) NPT Female connection rated to 125 psi (8.62 bar) and 130°F (54°C). It suits oem flow measurement and water flow measurement.
FL4000 OEM-style variable area flow meter are precisely machined from solid acrylic blocks. They are available in 50, 75, 127, and 250 mm (1.97, 2.96, 5, and 9.85") scale lengths and have accuracies between 2 and 6%. Designed for front-panel mounting, the rear ports extend through the panel for easy hookup.
Mounting threads are also provided. Units are available with and without valves.
Features
Applications
| Series | FL4000 Series |
| Type | variable area flow meter |
| Media | Water |
| Flow range | 6 to 60 GPH |
| Accuracy | ±6% full scale |
| Maximum pressure | 125 psi (8.62 bar) |
| Process connection | 1/4" (6.3 mm) NPT Female |
| Maximum temperature | 130°F (54°C) |
| Construction | Acrylic tube, 316 SS float and guide rod (no guide rod for FL4211 through FL4215 air meters), PVC end fittings (brass on FL4200 Series), EPR O-rings, optional brass valve |
| Capacities | Water: 6.5 GPH to 20 GPM; Air: 2 SCFH to 40 SCFM |
| Scale Lengths | 50, 75, 127, and 250 mm (1.97, 2.96, 5, and 9.85" (5, 7.5, 12.7, and 25 cm)) |
| Max Pressure/Temperature (Water Ranges) | 125 psig (8.62 bar) @ 70°F (21°C); 130°F (54°C) at 0 psig (0 bar) |
| Max Pressure/Temperature (Air Ranges) | 100 psig (6.89 bar) @ 70°F (21°C); 100°F (38°C) @ 0 psig (0 bar) |
| Full Scale Accuracy/Repeatability | FL4200: 6/2%; FL4300 and FL4400: 4/1%; FL4500: 3/1/2%; FL4600: 2/1/2% |
| Series | FL4000 Series |
| Type | variable area flow meter |
| Media | Water |
| Flow range | 6 to 60 GPH |
| Accuracy | ±6% full scale |
| Maximum pressure | 125 psi (8.62 bar) |
| Process connection | 1/4" (6.3 mm) NPT Female |
| Maximum temperature | 130°F (54°C) |
| Construction | Acrylic tube, 316 SS float and guide rod (no guide rod for FL4211 through FL4215 air meters), PVC end fittings (brass on FL4200 Series), EPR O-rings, optional brass valve |
| Capacities | Water: 6.5 GPH to 20 GPM; Air: 2 SCFH to 40 SCFM |
| Scale Lengths | 50, 75, 127, and 250 mm (1.97, 2.96, 5, and 9.85" (5, 7.5, 12.7, and 25 cm)) |
| Max Pressure/Temperature (Water Ranges) | 125 psig (8.62 bar) @ 70°F (21°C); 130°F (54°C) at 0 psig (0 bar) |
| Max Pressure/Temperature (Air Ranges) | 100 psig (6.89 bar) @ 70°F (21°C); 100°F (38°C) @ 0 psig (0 bar) |
| Full Scale Accuracy/Repeatability | FL4200: 6/2%; FL4300 and FL4400: 4/1%; FL4500: 3/1/2%; FL4600: 2/1/2% |