This DIN rail transmitter is configured for DIN Rail Compatible, TC/RTD/Resistance/Pot/mA/V I/P Type, Universal. It suits linearised, electronic temperature measurement with rtd or tc sensor and power supply and signal isolator for 2-wire transmitters.
This DIN rail transmitter is configured for DIN Rail Compatible, TC/RTD/Resistance/Pot/mA/V I/P Type, Universal. It suits linearised, electronic temperature measurement with rtd or tc sensor and power supply and signal isolator for 2-wire transmitters.
Universal transmitter with input for RTD, TC, Ohm, potentiometer, mA and V, and output for current and voltage. Provides linearised electronic temperature measurement and conversion of analogue signals, and is designed according to strict safety requirements making it suitable for application in SIL 2 installations.
Features
Applications
| Series | DRST-UN Series |
| Type | DIN rail transmitter |
| Panel size | DIN Rail Compatible |
| Input | TC/RTD/Resistance/Pot/mA/V I/P Type |
| Configuration | Universal |
| Output type | mA/V O/P Type |
| Configuration | Process |
| Configuration | AC/DC |
| Configuration | 2300 V |
| Configuration | Programmer Display |
| Configuration | Display Programmer |
| Supply voltage, universal | 21.6...253 V AC, 50...60 Hz or 19.2...300 V DC |
| Maximum consumption | ≤ 2.0 W |
| Fuse | 400 mA SB / 250 V AC |
| Isolation voltage, test / operation | 2.3 kV AC / 250 V AC |
| Communications interface | Communication enabler DRST-CM / Programming front DRSL-DISPLAY |
| Signal / noise ratio | Minimum 60 dB (0...100 kHz) |
| Current output signal range | 0...20 mA |
| Voltage output signal range | 0...10 V DC |
| Response time, temperature input (0...90%, 100...10%) | ≤ 1 s |
| Response time, mA / V input (0...90%, 100...10%) | ≤ 400 ms |
| Absolute accuracy (all input types) | ≤ ±0.1% of span |
| Temperature coefficient (all input types) | ≤ ±0.01% of span / °C |
| EMC immunity influence | < ±0.5% of span |
| Maximum wire size | 1 x 2.5 mm2 stranded wire |
| Screw terminal torque | 4.43 in-lb (0.5 Nm) |
| Protection degree | IP20 |
| Specifications range | -4 to 140°F (-20 to 60°C) |
| Calibration temperature | 68 to 82°F (20 to 28°C) |
| Relative humidity | < 95% RH (non-condensing) |
| Max. consumption | ≤ 2.0 W |
| Basic accuracy, mA | ≤ ±4 μA |
| Basic accuracy, Volt | ≤ ±20 μV |
| Basic accuracy, Pt100 | ≤ ±0.2°C |
| Basic accuracy, linear resistance | ≤ ±0.1 Ω |
| Basic accuracy, potentiometer | ≤ ±0.1 Ω |
| Basic accuracy, TC type E, J, K, L, N, T, U | ≤ ±1°C |
| Basic accuracy, TC type R, S, W3, W5, LR | ≤ ±2°C |
| Basic accuracy, TC type B (85...200°C) | ≤ ±4°C |
| Basic accuracy, TC type B (200...1820°C) | ≤ ±2°C |
| Extended EMC immunity, NAMUR NE 21, A criterion, burst | < ±1% of span |
| 2-wire supply (terminal 44...43) | 25...16 VDC / 0...20 mA |
| Input for RTD types | Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000, Cu10, Cu20, Cu50, Cu100 |
| RTD range, Pt10...Pt1000 | -328 to 1562°F (-328 to 1562°F (-200 to 850°C)) (IEC 60751) |
| RTD range, Ni50...Ni1000 | -76 to 482°F (-76 to 482°F (-60 to 250°C)) (DIN 43760) |
| RTD range, Cu10...Cu100 | -328 to 500°F (-328 to 500°F (-200 to 260°C)) (α = 0,00427) |
| Linear resistance range | 0 Ω to 10000 Ω |
| Potentiometer range | 10 Ω to 100 kΩ |
| Cable resistance per wire (maximum.), RTD | 50 Ω |
| Sensor current, RTD | Nom. 0.2 mA |
| Effect of sensor cable resistance (3-/4-wire), RTD | < 0.002 Ω / Ω |
| Short circuit detection, RTD | < 15 Ω |
| TC range, B | 32 to 3308°F (32 to 3308°F (0 to 1820°C)) (IEC 60584-1) |
| TC range, E | -148 to 1832°F (-148 to 1832°F (-100 to 1000°C)) (IEC 60584-1) |
| TC range, J | -148 to 2192°F (-148 to 2192°F (-100 to 1200°C)) (IEC 60584-1) |
| TC range, K | -292 to 2502°F (-292 to 2502°F (-180 to 1372°C)) (IEC 60584-1) |
| TC range, L | -328 to 1652°F (-328 to 1652°F (-200 to 900°C)) (DIN 43710) |
| TC range, N | -292 to 2372°F (-292 to 2372°F (-180 to 1300°C)) (IEC 60584-1) |
| TC range, R | -58 to 3200°F (-58 to 3200°F (-50 to 1760°C)) (IEC 60584-1) |
| TC range, S | -58 to 3200°F (-58 to 3200°F (-50 to 1760°C)) (IEC 60584-1) |
| TC range, T | -328 to 752°F (-328 to 752°F (-200 to 400°C)) (IEC 60584-1) |
| TC range, U | -328 to 1112°F (-328 to 1112°F (-200 to 600°C)) (DIN 43710) |
| TC range, W3 | 32 to 4172°F (32 to 4172°F (0 to 2300°C)) (ASTM E988-90) |
| TC range, W5 | 32 to 4172°F (32 to 4172°F (0 to 2300°C)) (ASTM E988-90) |
| TC range, LR | -328 to 1472°F (-328 to 1472°F (-200 to 800°C)) (GOST 3044-84) |
| Cold junction compensation (CJC) via external sensor 5910 | 20...28°C ≤ ±1°C; -20...20°C / 28...70°C ≤ ±2°C |
| CJC via internal CJC sensor | ±(2.0°C + 0.4°C * Δt) |
| Sensor error current, when detecting | Nom. 2 μA |
| Current input measurement range | 0...20 mA |
| Current input, programmable measurement ranges | 0...20 and 4...20 mA |
| Current input resistance | Nom. 20 Ω + PTC 50 Ω |
| Voltage input measurement range | 0...12 VDC |
| Voltage input, programmable measurement ranges | 0...1 / 0.2...1 / 0...5 / 1...5 / 0...10 and 2...10 VDC |
| Voltage input resistance | Nom. 10 MΩ |
| Current output, programmable signal ranges | 0...20 / 4...20 / 20...0 / 20...4 mA |
| Current output, load (maximum.) | 20 mA / 800 Ω / 16 VDC |
| Current output, load stability | ≤ 0.01% of span / 100 Ω |
| Current output, NAMUR NE 43 Upscale / Downscale | 23 mA / 3.5 mA |
| Current output limitation on 4...20 and 20...4 mA signals | 3.8...20.5 mA |
| Current output limitation on 0...20 and 20...0 mA signals | 0...20.5 mA |
| Current output, current limit | ≤ 28 mA |
| Voltage output, programmable signal ranges | 0...1 / 0.2...1 / 0...10 / 0...5 / 1...5 / 2...10 / 1...0 / 1...0.2 / 5...0 / 5...1 / 10...0 and 10...2 V |
| Voltage output, load (minimum.) | 500 kΩ |
| Max. wire size | 1 x 2.5 mm2 stranded wire |
| Vibration | IEC 60068-2-6 : 2007; 2...13.2 Hz ±0.04" (1 mm); 13.2...100 Hz ±0.7 g |
| Installation | Installation Category II, Pollution Degree 1, Insulation Class II |
| Galvanic isolation | 3-port 2.3 kVAC |
| Safety | Designed as SIL 2 device |
| Ex / I.S. approval, FM | Class I, Div. 2, Group A, B, C, D; Class I, Div. 2, Group IIC; Zone 2; Max. ambient temperature for T5 140°F (60°C) |
| Marine approval | Det Norske Veritas, Ships & Offshore Standard for Certification No. 2.4 |
| Observed authority requirements, EMC | 2004/108/EC, EN 61326-1 |
| Observed authority requirements, LVD | 2006/95/EC, EN 61010-1 |
| Observed authority requirements, UL | Standard for Safety UL 508 |
| Observed authority requirements, EAC | TR-CU 020/2011, EN 61326-1 |
| Dimensions (H x W x D) | 4.29 x 0.93 x 4.09" (109 x 23.5 x 104 mm) |
| Dimensions, with DRSL-DISPLAY/DRST-CM (HxBxD) | 109 x 23.5 x 116/5.16" (131 mm) |
| Weight | 5.11 oz (145 g) |
| Weight with DRSL-DISPLAY/DRST-CM | 5.64 oz (160 g) / 8.64 oz (245 g) |
Click on a category to view a selection of compatible accessories with the Omega DRST-UN DIN Rail Transmitter, universal input, mA/V output.
| Series | DRST-UN Series |
| Type | DIN rail transmitter |
| Panel size | DIN Rail Compatible |
| Input | TC/RTD/Resistance/Pot/mA/V I/P Type |
| Configuration | Universal |
| Output type | mA/V O/P Type |
| Configuration | Process |
| Configuration | AC/DC |
| Configuration | 2300 V |
| Configuration | Programmer Display |
| Configuration | Display Programmer |
| Supply voltage, universal | 21.6...253 V AC, 50...60 Hz or 19.2...300 V DC |
| Maximum consumption | ≤ 2.0 W |
| Fuse | 400 mA SB / 250 V AC |
| Isolation voltage, test / operation | 2.3 kV AC / 250 V AC |
| Communications interface | Communication enabler DRST-CM / Programming front DRSL-DISPLAY |
| Signal / noise ratio | Minimum 60 dB (0...100 kHz) |
| Current output signal range | 0...20 mA |
| Voltage output signal range | 0...10 V DC |
| Response time, temperature input (0...90%, 100...10%) | ≤ 1 s |
| Response time, mA / V input (0...90%, 100...10%) | ≤ 400 ms |
| Absolute accuracy (all input types) | ≤ ±0.1% of span |
| Temperature coefficient (all input types) | ≤ ±0.01% of span / °C |
| EMC immunity influence | < ±0.5% of span |
| Maximum wire size | 1 x 2.5 mm2 stranded wire |
| Screw terminal torque | 4.43 in-lb (0.5 Nm) |
| Protection degree | IP20 |
| Specifications range | -4 to 140°F (-20 to 60°C) |
| Calibration temperature | 68 to 82°F (20 to 28°C) |
| Relative humidity | < 95% RH (non-condensing) |
| Max. consumption | ≤ 2.0 W |
| Basic accuracy, mA | ≤ ±4 μA |
| Basic accuracy, Volt | ≤ ±20 μV |
| Basic accuracy, Pt100 | ≤ ±0.2°C |
| Basic accuracy, linear resistance | ≤ ±0.1 Ω |
| Basic accuracy, potentiometer | ≤ ±0.1 Ω |
| Basic accuracy, TC type E, J, K, L, N, T, U | ≤ ±1°C |
| Basic accuracy, TC type R, S, W3, W5, LR | ≤ ±2°C |
| Basic accuracy, TC type B (85...200°C) | ≤ ±4°C |
| Basic accuracy, TC type B (200...1820°C) | ≤ ±2°C |
| Extended EMC immunity, NAMUR NE 21, A criterion, burst | < ±1% of span |
| 2-wire supply (terminal 44...43) | 25...16 VDC / 0...20 mA |
| Input for RTD types | Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000, Cu10, Cu20, Cu50, Cu100 |
| RTD range, Pt10...Pt1000 | -328 to 1562°F (-328 to 1562°F (-200 to 850°C)) (IEC 60751) |
| RTD range, Ni50...Ni1000 | -76 to 482°F (-76 to 482°F (-60 to 250°C)) (DIN 43760) |
| RTD range, Cu10...Cu100 | -328 to 500°F (-328 to 500°F (-200 to 260°C)) (α = 0,00427) |
| Linear resistance range | 0 Ω to 10000 Ω |
| Potentiometer range | 10 Ω to 100 kΩ |
| Cable resistance per wire (maximum.), RTD | 50 Ω |
| Sensor current, RTD | Nom. 0.2 mA |
| Effect of sensor cable resistance (3-/4-wire), RTD | < 0.002 Ω / Ω |
| Short circuit detection, RTD | < 15 Ω |
| TC range, B | 32 to 3308°F (32 to 3308°F (0 to 1820°C)) (IEC 60584-1) |
| TC range, E | -148 to 1832°F (-148 to 1832°F (-100 to 1000°C)) (IEC 60584-1) |
| TC range, J | -148 to 2192°F (-148 to 2192°F (-100 to 1200°C)) (IEC 60584-1) |
| TC range, K | -292 to 2502°F (-292 to 2502°F (-180 to 1372°C)) (IEC 60584-1) |
| TC range, L | -328 to 1652°F (-328 to 1652°F (-200 to 900°C)) (DIN 43710) |
| TC range, N | -292 to 2372°F (-292 to 2372°F (-180 to 1300°C)) (IEC 60584-1) |
| TC range, R | -58 to 3200°F (-58 to 3200°F (-50 to 1760°C)) (IEC 60584-1) |
| TC range, S | -58 to 3200°F (-58 to 3200°F (-50 to 1760°C)) (IEC 60584-1) |
| TC range, T | -328 to 752°F (-328 to 752°F (-200 to 400°C)) (IEC 60584-1) |
| TC range, U | -328 to 1112°F (-328 to 1112°F (-200 to 600°C)) (DIN 43710) |
| TC range, W3 | 32 to 4172°F (32 to 4172°F (0 to 2300°C)) (ASTM E988-90) |
| TC range, W5 | 32 to 4172°F (32 to 4172°F (0 to 2300°C)) (ASTM E988-90) |
| TC range, LR | -328 to 1472°F (-328 to 1472°F (-200 to 800°C)) (GOST 3044-84) |
| Cold junction compensation (CJC) via external sensor 5910 | 20...28°C ≤ ±1°C; -20...20°C / 28...70°C ≤ ±2°C |
| CJC via internal CJC sensor | ±(2.0°C + 0.4°C * Δt) |
| Sensor error current, when detecting | Nom. 2 μA |
| Current input measurement range | 0...20 mA |
| Current input, programmable measurement ranges | 0...20 and 4...20 mA |
| Current input resistance | Nom. 20 Ω + PTC 50 Ω |
| Voltage input measurement range | 0...12 VDC |
| Voltage input, programmable measurement ranges | 0...1 / 0.2...1 / 0...5 / 1...5 / 0...10 and 2...10 VDC |
| Voltage input resistance | Nom. 10 MΩ |
| Current output, programmable signal ranges | 0...20 / 4...20 / 20...0 / 20...4 mA |
| Current output, load (maximum.) | 20 mA / 800 Ω / 16 VDC |
| Current output, load stability | ≤ 0.01% of span / 100 Ω |
| Current output, NAMUR NE 43 Upscale / Downscale | 23 mA / 3.5 mA |
| Current output limitation on 4...20 and 20...4 mA signals | 3.8...20.5 mA |
| Current output limitation on 0...20 and 20...0 mA signals | 0...20.5 mA |
| Current output, current limit | ≤ 28 mA |
| Voltage output, programmable signal ranges | 0...1 / 0.2...1 / 0...10 / 0...5 / 1...5 / 2...10 / 1...0 / 1...0.2 / 5...0 / 5...1 / 10...0 and 10...2 V |
| Voltage output, load (minimum.) | 500 kΩ |
| Max. wire size | 1 x 2.5 mm2 stranded wire |
| Vibration | IEC 60068-2-6 : 2007; 2...13.2 Hz ±0.04" (1 mm); 13.2...100 Hz ±0.7 g |
| Installation | Installation Category II, Pollution Degree 1, Insulation Class II |
| Galvanic isolation | 3-port 2.3 kVAC |
| Safety | Designed as SIL 2 device |
| Ex / I.S. approval, FM | Class I, Div. 2, Group A, B, C, D; Class I, Div. 2, Group IIC; Zone 2; Max. ambient temperature for T5 140°F (60°C) |
| Marine approval | Det Norske Veritas, Ships & Offshore Standard for Certification No. 2.4 |
| Observed authority requirements, EMC | 2004/108/EC, EN 61326-1 |
| Observed authority requirements, LVD | 2006/95/EC, EN 61010-1 |
| Observed authority requirements, UL | Standard for Safety UL 508 |
| Observed authority requirements, EAC | TR-CU 020/2011, EN 61326-1 |
| Dimensions (H x W x D) | 4.29 x 0.93 x 4.09" (109 x 23.5 x 104 mm) |
| Dimensions, with DRSL-DISPLAY/DRST-CM (HxBxD) | 109 x 23.5 x 116/5.16" (131 mm) |
| Weight | 5.11 oz (145 g) |
| Weight with DRSL-DISPLAY/DRST-CM | 5.64 oz (160 g) / 8.64 oz (245 g) |
Click on a category to view a selection of compatible accessories with the Omega DRST-UN DIN Rail Transmitter, universal input, mA/V output.