Configured for Alarm, Analog Output, Gauge, this digital pressure gauge suits pressure alarm and process control and industrial pressure indication with alarm output.
Configured for Alarm, Analog Output, Gauge, this digital pressure gauge suits pressure alarm and process control and industrial pressure indication with alarm output.
The DPG1000ADA is AC/DC powered with dual alarms. The contacts of the alarm relays are rated at 1 A/24 V DC or 0.5 A/115 V AC.
Features
Applications
| Series | DPG1000ADA Series |
| Type | digital pressure gauge |
| Configuration | Alarm |
| Output type | Analog Output |
| Configuration | Gauge |
| Configuration | 0 psi (0 bar) to 3000 psi (206.84 bar) |
| Accuracy | ± 0.25 % |
| Configuration | 1/4" (6.3 mm) NPT Male |
| Display | 4 Digit |
| Configuration | AC/DC Powered |
| Supply voltage | SPDT 1 A 24 V DC/0.5 V AC |
| Configuration | Hi/Lo Normal Action |
| Accuracy | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability) |
| Alarm Deadbands (Hysteresis) | 1% of FSO, standard |
| Alarm Outputs | Dual form "C" (SPDT) relay contacts; relay contacts rated 1 A/24 V DC, 0.5 A/115 V AC, non-inductive |
| Alarm Indicators | Bicolor (red/green) LEDs on front panel |
| Alarm Response Time | 100 ms typical |
| Power | Any AC source of 8 to 24 V AC, 50/60 Hz, or any DC source of 9 to 32 V DC, 1.0 W maximum |
| Electrical Connection | 3' (0.9 m) long, 2-conductor 22 AWG cable for power; 3' (0.9 m), 6-conductor 22 AWG cable for alarm contacts |
| Sensor | Precision oil-filled silicon |
| Controls and Location (ADA) | Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers |
| Controls and Location (DAR) | Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; test calibration level, 0 to 100% range; top-accessible, multiturn potentiometers; analog output zero/span internal potentiometers |
| Analog Output (DAR) | 4 to 20 mA DC; output drive (compliance) determined by power source |
| Analog Output Response Time (DAR) | 50 ms, typical |
| Test Function | Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation (DAR also simultaneously sets display and analog output to "calibration" level) |
| Contact Rating and Protection | Contacts of the alarm relays rated at 1 A/24 V DC or 0.5 A/115 V AC; no internal fusing included |
| Alarm Configurations | 1 HI/LO (standard), 2 HI/HI, 3 LO/LO; N Normal acting (standard), R Reverse acting |
| Series | DPG1000ADA Series |
| Type | digital pressure gauge |
| Configuration | Alarm |
| Output type | Analog Output |
| Configuration | Gauge |
| Configuration | 0 psi (0 bar) to 3000 psi (206.84 bar) |
| Accuracy | ± 0.25 % |
| Configuration | 1/4" (6.3 mm) NPT Male |
| Display | 4 Digit |
| Configuration | AC/DC Powered |
| Supply voltage | SPDT 1 A 24 V DC/0.5 V AC |
| Configuration | Hi/Lo Normal Action |
| Accuracy | ±0.25% FSO or better, ±1 least-significant digit (includes linearity, hysteresis, repeatability) |
| Alarm Deadbands (Hysteresis) | 1% of FSO, standard |
| Alarm Outputs | Dual form "C" (SPDT) relay contacts; relay contacts rated 1 A/24 V DC, 0.5 A/115 V AC, non-inductive |
| Alarm Indicators | Bicolor (red/green) LEDs on front panel |
| Alarm Response Time | 100 ms typical |
| Power | Any AC source of 8 to 24 V AC, 50/60 Hz, or any DC source of 9 to 32 V DC, 1.0 W maximum |
| Electrical Connection | 3' (0.9 m) long, 2-conductor 22 AWG cable for power; 3' (0.9 m), 6-conductor 22 AWG cable for alarm contacts |
| Sensor | Precision oil-filled silicon |
| Controls and Location (ADA) | Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; top-accessible, multiturn potentiometers |
| Controls and Location (DAR) | Display zero/span, non-interactive, ±15% range; setpoint 1 and setpoint 2, 0 to 100% range; test calibration level, 0 to 100% range; top-accessible, multiturn potentiometers; analog output zero/span internal potentiometers |
| Analog Output (DAR) | 4 to 20 mA DC; output drive (compliance) determined by power source |
| Analog Output Response Time (DAR) | 50 ms, typical |
| Test Function | Front-panel TEST button, when depressed, toggles both SP1 and SP2 alarm status, independent of pressure input, to allow testing of system operation (DAR also simultaneously sets display and analog output to "calibration" level) |
| Contact Rating and Protection | Contacts of the alarm relays rated at 1 A/24 V DC or 0.5 A/115 V AC; no internal fusing included |
| Alarm Configurations | 1 HI/LO (standard), 2 HI/HI, 3 LO/LO; N Normal acting (standard), R Reverse acting |