Omega DP20 Series Panel Meter, isolated Modbus RTU output, universal input

Model: DP20-S1

Omega DP20 Series Panel Meter, isolated Modbus RTU output, universal input

Model: DP20-S1

This panel meter is configured for Isolated Modbus RTU O/P. It suits assembly line and laboratory.

This panel meter is configured for Isolated Modbus RTU O/P. It suits assembly line and laboratory.

Your Price $404.00 CAD
Availability 2 to 3 Weeks
Quantity

OMEGA DP20-S1 Offers

OMEGA's new multisignal panel meter delivers high-performance in a 1/8 DIN size for panel mounts and integration in a wide range of applications. The DP20 accepts universal inputs, including thermocouple, RTD, process (mA & Vdc), resistance, frequency and true RMS voltage and current.

OMEGA's multisignal panel meter delivers high-performance in a 1/8 DIN size for panel mounts and integration in a wide range of applications. The DP20 accepts universal inputs, including thermocouple, RTD, process (mA and V DC), resistance, frequency and true RMS voltage and current.

A single universal power supply allows this unit to be suited for global use. The optional relays, analog output, and Modbus(R) RTU serial communications provide customization, control and communication capability.

By configuration, it will work as an AC and DC voltmeter (up to 600 V) and AC and DC ammeter (up to 5 A) offering application flexibility for process control and industrial requirements. A single universal power supply allows this unit to be suited for global use.

Additional features of the economical DP20 panel meter include scaling, NEMA 4 (IP65) protection, and programmable decimal points.

Features

  • Fast access menu—front key access to modify the alarm setpoints and Max/Min memory
  • Universal inputs, including thermocouple, RTD, process (mA and v DC), resistance, frequency and true rms voltage and current
  • External control function—contact at multifunctional terminal 5 (second scaling, decimal point change, 'Hold' the reading tare or activate the Max/Min memory)
  • Works as an AC and DC voltmeter (up to 600 v) and AC and DC ammeter (up to 5 A)
  • Automatic, power saving Eco mode
  • Single universal power supply allows this unit to be suited for global use
  • Alarms 1 or 2, independent, configurable as Max/Min, with setpoint and hysteresis
  • Optional relays, analog output, and modbus rtu serial communications provide customization, control and communication capability
  • Reading offset—configure a fixed number of counts to be added to the reading
  • Scaling, NEMA 4 (IP65) protection, and programmable decimal points
  • Second scaling function—define two scalings for the same signal and control (one is active with the 'External Control' option)
  • Reading offset, configure a fixed number of counts to be added to the reading
  • Recursive display filter for noisy signals and configurable steps for minimum predefined changes on the reading
  • Second scaling function, define two scalings for the same signal
  • Output and control options: 1 or 2 relay outputs, 1 analog 4 to 20 mA isolated output, 1 Modbus RTU isolated serial output
  • Fast access menu, front key access to modify the alarm setpoints and maximum/min memory
  • 5 levels of brightness intensity
  • External control function, contact at multifunctional terminal 5
  • Password protection
  • Automatic, power saving eco mode
  • Alarms 1 or 2, independent, configurable as maximum/min, with setpoint and hysteresis
  • 5 levels of brightness intensity
  • Password protection
  • Recursive display filter for noisy signals and configurable steps
  • Output and control options: 1 or 2 relay outputs, 1 analog 4 to 20 mA isolated output, 1 modbus rtu isolated serial output

Applications

  • Monitoring process signals on an assembly line
  • Assembly line
  • Displaying temperature and electrical readings at a control panel
  • Control panel
  • Taking RTD and thermocouple measurements in a laboratory
  • Laboratory
  • Panel-mounted AC/DC voltage and current metering for industrial equipment
  • Process control
  • Industrial measurement

OMEGA DP20-S1 Specifications

Series DP20 Series
Digits 4
Type panel meter
Reading 9999 / -1999
Output type Isolated Modbus RTU O/P
Decimal point Configurable
Digits 4
LED color Red
Reading 9999 / -1999
Digit height 0.55" (14 mm)
Decimal Point Configurable
Thermocouples K, J, E, N, L, R, S, B, T and C (automatic cold junction compensation)
LED Color Red
Resistive 'Pt' probes Pt100 with 2 and 3 wires, Pt500, Pt1000
Digit Height 0.55" (14 mm)
Resistive 'Ni' probes Ni100, Ni200, Ni1000
Protection NEMA 4 (IP65)
Resistive PTC probes Families KTY-121, KTY-210 and KTY-220
Power 'U' 18 to 265 V AC/DC (isolated 1500 Veff @ 60 seconds)
Process 4/20 mA, 0/10 Vdc (+15 Vdc excitation voltage configurable at terminal 5)
Consumption (Normal Mode) <1.0 W (meter only), <2.5 W (meter with options)
Resistances Ranges 0/5 K and 0/50 K
Consumption ('Eco' Mode) <0.3 W (meter only), <1.5 W (meter with options)
Potentiometers With nominal values from 500 R up to 20 K
Connections Plug-in screw terminals
Frequency up to 100 Hz (minimum 15 Hz), Vac and Aac ranges
Thermocouples K, J, E, N, L, R, S, B, T and C (automatic cold junction compensation)
Thermal drift offset+span 150 ppm/°C
Resistive 'Pt' Probes Pt100 with 2 and 3 wires, Pt500, Pt1000
Readings 3 readings/second
Resistive 'Ni' Probes Ni100, Ni200, Ni1000
Refresh 3 readings/second
Resistive PTC Probes Families KTY-121, KTY-210 and KTY-220
Response time less than 300 mSec. (0 % to 99 % of signal)
Process 4/20 mA, 0/10 V DC (+15 V DC excitation voltage configurable at terminal 5)
Power 'U' 18 to 265 Vac/dc (isolated 1500 Veff @ 60 seconds)
Resistances Ranges 0/5 K and 0/50 K
Protection NEMA 4 (IP65)
Potentiometers With nominal values from 500 R up to 20 K
Consumption (normal mode) less than 1.0 W (meter only), less than 2.5 W (meter with options)
Frequency up to 100 Hz (minimum 15 Hz), V AC and A AC ranges
Consumption ('Eco' mode) less than 0.3 W (meter only), less than 1.5 W (meter with options)
Thermal Drift Offset+Span 150 ppm/°C
Connections Plug-in screw terminals
Readings 3 readings/second
Operation temperature 32 to 122°F (0 to 50°C)
Response Time <300 mSec. (0 % to 99 % of signal)
Modbus RTU output (S1) 1 Modbus RTU output, 9,600 bps, 4,800 bps, isolated 1000 Vdc
Panel Cut-Out 3.63 x 1.74" (92 x 44 mm)
Dimensions 1.89" x 3.78" x 2.95" (48 x 96 x 75 mm)
Body depth (including terminal): 2.95" (75 mm)
Panel cut-out: 1.74" x 3.63" (44 x 92 mm)
Operation Temperature 32 to 122°F (0 to 50°C)
Weight less than 5.3 oz (150 g)
AC Voltages and AC Currents 600 V AC, 200 V AC, 20 V AC, 2 V AC, 200 mVac, 60 mVac, 5 Aac, 20 mAac (True RMS measure) (accepts phase-neutral and phase-phase measure)
DC Voltages and DC Currents ±600 V DC, ±200 V DC, ±20 V DC, ±2 V DC, ±200 mVdc, ±60 mVdc, ±5 Adc, ±20 mAdc
Resistive NTC Probes R25 configurable 10K, range -76 to 302°F (-76 to 302°F (-60 to 150°C)), accuracy <1.5% of reading, Beta configurable (2000 to 5500), resistance measure from 100R to 1MR
V AC Accuracy <0.30% FS (up to 150 Hz)
V DC Accuracy <0.20% FS (<0.25% for 60 mVdc range)
Aac Accuracy <0.50% FS (up to 150 Hz)
Adc Accuracy <0.25% FS (±5 Adc); <0.15% FS (±20 mAdc)
Process Signals Accuracy 4/20 mA <0.15% FS; 0/10 V DC <0.20% FS
Thermocouple Ranges K -100 to 1350 (-148 to 2462); J -100 to 1200; E -100 to 1000; N -100 to 1300; L -100 to 900; R 0 to 1768; S 0 to 1768; T -100 to 400; C 0 to 2300; B 1292 to 3308°F (700 to 1820°C) (°F). Total error <3° (K,J,E,N,L,R,S,T), <5° (C,B), cold junction included
Pt/Ni Probe Ranges Pt100 (3 wires) -200 to 700; Pt100 (2 wires) -200 to 700; Pt500 -150 to 630; Pt1000 -190 to 630; Ni100 -60 to 180; Ni200 -60 to 120; Ni1000 -76 to 356°F (-60 to 180°C), total error <1°
Relay Outputs 1 or 2 relay outputs; 3 contacts (NC, NO, Common) up to 250 V AC @ 8A resistive load
Analog Output 1 analog output isolated 4/20 mA, isolated 1000 V DC
Modbus RTU Output 1 Modbus RTU output, 9,600 bps / 4,800 bps, isolated 1000 V DC
Weight 5.3 oz (<150 g)

What's included with the OMEGA DP20-S1

  • 1/8 DIN Multisignal Panel Meter
  • Operator's Manual
  • Male and Female Plug-in Screw Terminals

Ask a question about Omega DP20 Series Panel Meter, isolated Modbus RTU output, universal input

Customer Reviews for the OMEGA DP20-S1

OMEGA DP20-S1 Offers

OMEGA's new multisignal panel meter delivers high-performance in a 1/8 DIN size for panel mounts and integration in a wide range of applications. The DP20 accepts universal inputs, including thermocouple, RTD, process (mA & Vdc), resistance, frequency and true RMS voltage and current.

OMEGA's multisignal panel meter delivers high-performance in a 1/8 DIN size for panel mounts and integration in a wide range of applications. The DP20 accepts universal inputs, including thermocouple, RTD, process (mA and V DC), resistance, frequency and true RMS voltage and current.

A single universal power supply allows this unit to be suited for global use. The optional relays, analog output, and Modbus(R) RTU serial communications provide customization, control and communication capability.

By configuration, it will work as an AC and DC voltmeter (up to 600 V) and AC and DC ammeter (up to 5 A) offering application flexibility for process control and industrial requirements. A single universal power supply allows this unit to be suited for global use.

Additional features of the economical DP20 panel meter include scaling, NEMA 4 (IP65) protection, and programmable decimal points.

Features

  • Fast access menu—front key access to modify the alarm setpoints and Max/Min memory
  • Universal inputs, including thermocouple, RTD, process (mA and v DC), resistance, frequency and true rms voltage and current
  • External control function—contact at multifunctional terminal 5 (second scaling, decimal point change, 'Hold' the reading tare or activate the Max/Min memory)
  • Works as an AC and DC voltmeter (up to 600 v) and AC and DC ammeter (up to 5 A)
  • Automatic, power saving Eco mode
  • Single universal power supply allows this unit to be suited for global use
  • Alarms 1 or 2, independent, configurable as Max/Min, with setpoint and hysteresis
  • Optional relays, analog output, and modbus rtu serial communications provide customization, control and communication capability
  • Reading offset—configure a fixed number of counts to be added to the reading
  • Scaling, NEMA 4 (IP65) protection, and programmable decimal points
  • Second scaling function—define two scalings for the same signal and control (one is active with the 'External Control' option)
  • Reading offset, configure a fixed number of counts to be added to the reading
  • Recursive display filter for noisy signals and configurable steps for minimum predefined changes on the reading
  • Second scaling function, define two scalings for the same signal
  • Output and control options: 1 or 2 relay outputs, 1 analog 4 to 20 mA isolated output, 1 Modbus RTU isolated serial output
  • Fast access menu, front key access to modify the alarm setpoints and maximum/min memory
  • 5 levels of brightness intensity
  • External control function, contact at multifunctional terminal 5
  • Password protection
  • Automatic, power saving eco mode
  • Alarms 1 or 2, independent, configurable as maximum/min, with setpoint and hysteresis
  • 5 levels of brightness intensity
  • Password protection
  • Recursive display filter for noisy signals and configurable steps
  • Output and control options: 1 or 2 relay outputs, 1 analog 4 to 20 mA isolated output, 1 modbus rtu isolated serial output

Applications

  • Monitoring process signals on an assembly line
  • Assembly line
  • Displaying temperature and electrical readings at a control panel
  • Control panel
  • Taking RTD and thermocouple measurements in a laboratory
  • Laboratory
  • Panel-mounted AC/DC voltage and current metering for industrial equipment
  • Process control
  • Industrial measurement

OMEGA DP20-S1 Specifications

Series DP20 Series
Digits 4
Type panel meter
Reading 9999 / -1999
Output type Isolated Modbus RTU O/P
Decimal point Configurable
Digits 4
LED color Red
Reading 9999 / -1999
Digit height 0.55" (14 mm)
Decimal Point Configurable
Thermocouples K, J, E, N, L, R, S, B, T and C (automatic cold junction compensation)
LED Color Red
Resistive 'Pt' probes Pt100 with 2 and 3 wires, Pt500, Pt1000
Digit Height 0.55" (14 mm)
Resistive 'Ni' probes Ni100, Ni200, Ni1000
Protection NEMA 4 (IP65)
Resistive PTC probes Families KTY-121, KTY-210 and KTY-220
Power 'U' 18 to 265 V AC/DC (isolated 1500 Veff @ 60 seconds)
Process 4/20 mA, 0/10 Vdc (+15 Vdc excitation voltage configurable at terminal 5)
Consumption (Normal Mode) <1.0 W (meter only), <2.5 W (meter with options)
Resistances Ranges 0/5 K and 0/50 K
Consumption ('Eco' Mode) <0.3 W (meter only), <1.5 W (meter with options)
Potentiometers With nominal values from 500 R up to 20 K
Connections Plug-in screw terminals
Frequency up to 100 Hz (minimum 15 Hz), Vac and Aac ranges
Thermocouples K, J, E, N, L, R, S, B, T and C (automatic cold junction compensation)
Thermal drift offset+span 150 ppm/°C
Resistive 'Pt' Probes Pt100 with 2 and 3 wires, Pt500, Pt1000
Readings 3 readings/second
Resistive 'Ni' Probes Ni100, Ni200, Ni1000
Refresh 3 readings/second
Resistive PTC Probes Families KTY-121, KTY-210 and KTY-220
Response time less than 300 mSec. (0 % to 99 % of signal)
Process 4/20 mA, 0/10 V DC (+15 V DC excitation voltage configurable at terminal 5)
Power 'U' 18 to 265 Vac/dc (isolated 1500 Veff @ 60 seconds)
Resistances Ranges 0/5 K and 0/50 K
Protection NEMA 4 (IP65)
Potentiometers With nominal values from 500 R up to 20 K
Consumption (normal mode) less than 1.0 W (meter only), less than 2.5 W (meter with options)
Frequency up to 100 Hz (minimum 15 Hz), V AC and A AC ranges
Consumption ('Eco' mode) less than 0.3 W (meter only), less than 1.5 W (meter with options)
Thermal Drift Offset+Span 150 ppm/°C
Connections Plug-in screw terminals
Readings 3 readings/second
Operation temperature 32 to 122°F (0 to 50°C)
Response Time <300 mSec. (0 % to 99 % of signal)
Modbus RTU output (S1) 1 Modbus RTU output, 9,600 bps, 4,800 bps, isolated 1000 Vdc
Panel Cut-Out 3.63 x 1.74" (92 x 44 mm)
Dimensions 1.89" x 3.78" x 2.95" (48 x 96 x 75 mm)
Body depth (including terminal): 2.95" (75 mm)
Panel cut-out: 1.74" x 3.63" (44 x 92 mm)
Operation Temperature 32 to 122°F (0 to 50°C)
Weight less than 5.3 oz (150 g)
AC Voltages and AC Currents 600 V AC, 200 V AC, 20 V AC, 2 V AC, 200 mVac, 60 mVac, 5 Aac, 20 mAac (True RMS measure) (accepts phase-neutral and phase-phase measure)
DC Voltages and DC Currents ±600 V DC, ±200 V DC, ±20 V DC, ±2 V DC, ±200 mVdc, ±60 mVdc, ±5 Adc, ±20 mAdc
Resistive NTC Probes R25 configurable 10K, range -76 to 302°F (-76 to 302°F (-60 to 150°C)), accuracy <1.5% of reading, Beta configurable (2000 to 5500), resistance measure from 100R to 1MR
V AC Accuracy <0.30% FS (up to 150 Hz)
V DC Accuracy <0.20% FS (<0.25% for 60 mVdc range)
Aac Accuracy <0.50% FS (up to 150 Hz)
Adc Accuracy <0.25% FS (±5 Adc); <0.15% FS (±20 mAdc)
Process Signals Accuracy 4/20 mA <0.15% FS; 0/10 V DC <0.20% FS
Thermocouple Ranges K -100 to 1350 (-148 to 2462); J -100 to 1200; E -100 to 1000; N -100 to 1300; L -100 to 900; R 0 to 1768; S 0 to 1768; T -100 to 400; C 0 to 2300; B 1292 to 3308°F (700 to 1820°C) (°F). Total error <3° (K,J,E,N,L,R,S,T), <5° (C,B), cold junction included
Pt/Ni Probe Ranges Pt100 (3 wires) -200 to 700; Pt100 (2 wires) -200 to 700; Pt500 -150 to 630; Pt1000 -190 to 630; Ni100 -60 to 180; Ni200 -60 to 120; Ni1000 -76 to 356°F (-60 to 180°C), total error <1°
Relay Outputs 1 or 2 relay outputs; 3 contacts (NC, NO, Common) up to 250 V AC @ 8A resistive load
Analog Output 1 analog output isolated 4/20 mA, isolated 1000 V DC
Modbus RTU Output 1 Modbus RTU output, 9,600 bps / 4,800 bps, isolated 1000 V DC
Weight 5.3 oz (<150 g)

What's included with the OMEGA DP20-S1

  • 1/8 DIN Multisignal Panel Meter
  • Operator's Manual
  • Male and Female Plug-in Screw Terminals

Ask a question about Omega DP20 Series Panel Meter, isolated Modbus RTU output, universal input

Customer Reviews for the OMEGA DP20-S1