Measures pH, mV and temperature; making it ideal for water quality testing in the lab. Compact design is over 40% smaller than other benchtop meters. This model comes precalibrated

Measures pH, mV and temperature; making it ideal for water quality testing in the lab. Compact design is over 40% smaller than other benchtop meters. This model comes precalibrated

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Environmental Express pH 2000 Benchtop Meter with Electrode Stand-

Environmental Express pH 2000 Benchtop Meter with Electrode Stand

Model: 35419-55

Our new Environmental Express 2000 series meters, developed with extensive input from laboratory professionals, are available in multiple configurations designed to measure pH and mV parameters.


Not what you're looking for? Let’s do a search and help you find what you need.


OAKTON PH 2700 Offers

Features

  • Takes up less bench space – Overall footprint is nearly 40% smaller than other benchtop meters
  • Oversized liquid crystal display with bright backlighting – Easier viewing under all lighting conditions
  • Dynamic reading stability indication shows when you when your measurement is stable – Eliminates guesswork from unstable readings
  • Auto pH buffer recognition for up to 6-point calibrations – Choose USA, NIST, DIN or custom buffer sets
  • Up to 500 point nonvolatile memory with time-and-date stamp – Meets Good Laboratory Practice (GLP) requirements
  • Bidirectional RS-232 – For easy data transfer to your computer
  • Calibration documentation – Allows you to display, download, or print out calibration details like date and time, buffer valves, offset, and slope
  • Cal-due alarms – Visual and audible reminders when recalibration is needed
  • Audible out-of-range alarms – Indicate when a reading is above or below a user-settable range
  • Electrode status – Provides the diagnostics needed to determine when electrode service or replacement is needed
  • Password protection – Prevents unauthorized setup and calibration

Applications

  • Laboratory
  • Water Quality
  • Electrode Diagnosis

OAKTON PH 2700 Specifications

pH
Range –2.000 to 20.000 pH
Resolution 0.001, 0.01, 0.1 pH
Accuracy ±0.002 + 1 LSD
Calibration Up to 6 (USA, NIST, DIN, or custom buffer sets)
Connectors BNC
mV
Range ±2000.0 mV
Resolution 0.1 mV
Accuracy ±0.2 mV
Calibration Offset up to +150 mV
Connectors BNC
Temperature
Range 0.0 to 100.0°C (32.0 to 212°F)
Resolution 0.1°C or °F
Accuracy ±0.3°C (±0.5°F)
Connectors 2.5 mm phono
Click here for complete specifications on the OAKTON PH 2700

What's included with the OAKTON PH 2700

  • PH 2700 Benchtop pH Meter
  • Electrode Holder
  • AC Adapter

Oakton 2700 Series Benchtop pH Meters

Click on a category to view a selection of compatible accessories with the OAKTON PH 2700 Benchtop pH Meter with Calibration.

OAKTON WD-35608-72 Conductivity Probe for 700 & 2700 Meters, K=0.1, Epoxy Body WD-35608-72
This probe can be used for low conductivity measurements that are near or below 20mS. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-90 Conductivity Probe for 700 & 2700 Meters, K=0.1, Four Cell WD-35608-90
This probe can be used for low conductivity measurements that are near or below 20mS. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-76 Conductivity Probe for 700 & 2700 Meters, K=1.0, Epoxy Body WD-35608-76
Having a 1.0K cell constant is ideal for midrange conductivity measurements. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-92 Conductivity Probe for 700 & 2700 Meters, K=1.0, Four Cell WD-35608-92
Having a 1.0K cell constant is ideal for midrange conductivity measurements. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-74 Conductivity Probe for 700 & 2700 Meters, K=1.0, Ultem Body WD-35608-74
Having a 1.0K cell constant is ideal for midrange conductivity measurements. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-78 Conductivity Probe for 700 & 2700 Meters, K=10, Epoxy Body WD-35608-78
This probe can be used for high conductivity measurements that are near or above 20mS. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-94 Conductivity Probe for 700 & 2700 Meters, K=10, Four Cell WD-35608-94
This probe can be used for high conductivity measurements that are near or above 20mS. For use with CON 700/2700 and PC 700/2700.




Ask a question about OAKTON PH 2700 Benchtop pH Meter with Calibration

Customer Reviews for the OAKTON PH 2700

OAKTON PH 2700 Offers

Features

  • Takes up less bench space – Overall footprint is nearly 40% smaller than other benchtop meters
  • Oversized liquid crystal display with bright backlighting – Easier viewing under all lighting conditions
  • Dynamic reading stability indication shows when you when your measurement is stable – Eliminates guesswork from unstable readings
  • Auto pH buffer recognition for up to 6-point calibrations – Choose USA, NIST, DIN or custom buffer sets
  • Up to 500 point nonvolatile memory with time-and-date stamp – Meets Good Laboratory Practice (GLP) requirements
  • Bidirectional RS-232 – For easy data transfer to your computer
  • Calibration documentation – Allows you to display, download, or print out calibration details like date and time, buffer valves, offset, and slope
  • Cal-due alarms – Visual and audible reminders when recalibration is needed
  • Audible out-of-range alarms – Indicate when a reading is above or below a user-settable range
  • Electrode status – Provides the diagnostics needed to determine when electrode service or replacement is needed
  • Password protection – Prevents unauthorized setup and calibration

Applications

  • Laboratory
  • Water Quality
  • Electrode Diagnosis

OAKTON PH 2700 Specifications

pH
Range –2.000 to 20.000 pH
Resolution 0.001, 0.01, 0.1 pH
Accuracy ±0.002 + 1 LSD
Calibration Up to 6 (USA, NIST, DIN, or custom buffer sets)
Connectors BNC
mV
Range ±2000.0 mV
Resolution 0.1 mV
Accuracy ±0.2 mV
Calibration Offset up to +150 mV
Connectors BNC
Temperature
Range 0.0 to 100.0°C (32.0 to 212°F)
Resolution 0.1°C or °F
Accuracy ±0.3°C (±0.5°F)
Connectors 2.5 mm phono
Click here for complete specifications on the OAKTON PH 2700

What's included with the OAKTON PH 2700

  • PH 2700 Benchtop pH Meter
  • Electrode Holder
  • AC Adapter

Oakton 2700 Series Benchtop pH Meters

Click on a category to view a selection of compatible accessories with the OAKTON PH 2700 Benchtop pH Meter with Calibration.

OAKTON WD-35608-72 Conductivity Probe for 700 & 2700 Meters, K=0.1, Epoxy Body WD-35608-72
This probe can be used for low conductivity measurements that are near or below 20mS. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-90 Conductivity Probe for 700 & 2700 Meters, K=0.1, Four Cell WD-35608-90
This probe can be used for low conductivity measurements that are near or below 20mS. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-76 Conductivity Probe for 700 & 2700 Meters, K=1.0, Epoxy Body WD-35608-76
Having a 1.0K cell constant is ideal for midrange conductivity measurements. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-92 Conductivity Probe for 700 & 2700 Meters, K=1.0, Four Cell WD-35608-92
Having a 1.0K cell constant is ideal for midrange conductivity measurements. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-74 Conductivity Probe for 700 & 2700 Meters, K=1.0, Ultem Body WD-35608-74
Having a 1.0K cell constant is ideal for midrange conductivity measurements. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-78 Conductivity Probe for 700 & 2700 Meters, K=10, Epoxy Body WD-35608-78
This probe can be used for high conductivity measurements that are near or above 20mS. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-94 Conductivity Probe for 700 & 2700 Meters, K=10, Four Cell WD-35608-94
This probe can be used for high conductivity measurements that are near or above 20mS. For use with CON 700/2700 and PC 700/2700.




Ask a question about OAKTON PH 2700 Benchtop pH Meter with Calibration

Customer Reviews for the OAKTON PH 2700

More OAKTON Products