Robust, linear, and stable for measurements in gases such as biogas, methane, hydrogen, nitrogen, or carbon dioxide, this hazardous area oxygen analyzer with Viton o-ring meets the requirements of IEC61508 SIL2. Come with an IP66 rugged casing, 0 to 25% range, and ATEX/IECEx classification.
Robust, linear, and stable for measurements in gases such as biogas, methane, hydrogen, nitrogen, or carbon dioxide, this hazardous area oxygen analyzer with Viton o-ring meets the requirements of IEC61508 SIL2. Come with an IP66 rugged casing, 0 to 25% range, and ATEX/IECEx classification.
Discontinued!
This product has been discontinued and is no longer available. There are no replacement options.
We can help you find what you need:
The analyzer is housed in an IP66 rugged casing, making it suitable for a wide range of applications.
Features
Applications
High sensor-stability
Reliable long-term performance
Easy installation with local display
| Measurement Range | 0 to 25% |
| Measurement Technology | Thermo-paramagnetic oxygen sensor |
| Accuracy Excluding Suppressed Zero Ranges | ±0.02 % O2 or <±1 % of range, whichever is greater |
| Accuracy For Suppressed Zero Ranges (80/90 to 100 %) | ±0.2 % O2 or <±1 % of range, whichever is greater |
| Response Time (T90) with High Speed Response (HSR) Enabled | < 15 seconds |
| Sample Flow Effect | GP1 and GP3: 100 to 500 ml/min (0.2 to 1.06 scfh) EX1, EX3 and GP2: 270 to 330 ml/min (0.2 to 1.06 scfh) |
| Sample Pressure | 0.75 to 2 BarA |
| Sample Temperature | 41 to 131°F (5 to 55°C) maximum (113°F (45°C) for standard cell) |
| Gas | Process and non-condensing sample with particles <5 µm |
| Display Type | Backlit LCD |
| O-Ring Material | Viton |
| Hazardous Area Classification | ATEX/IECEx |
| Dimensions | 9.21 x 9.21 x 6.77"; (234 x 234 x 172 mm) |
| Weight | 21.38 lbs (9.7 kg) |
Analyzer
Hazardous Area Certificate
Calibration Certificate
| Measurement Range | 0 to 25% |
| Measurement Technology | Thermo-paramagnetic oxygen sensor |
| Accuracy Excluding Suppressed Zero Ranges | ±0.02 % O2 or <±1 % of range, whichever is greater |
| Accuracy For Suppressed Zero Ranges (80/90 to 100 %) | ±0.2 % O2 or <±1 % of range, whichever is greater |
| Response Time (T90) with High Speed Response (HSR) Enabled | < 15 seconds |
| Sample Flow Effect | GP1 and GP3: 100 to 500 ml/min (0.2 to 1.06 scfh) EX1, EX3 and GP2: 270 to 330 ml/min (0.2 to 1.06 scfh) |
| Sample Pressure | 0.75 to 2 BarA |
| Sample Temperature | 41 to 131°F (5 to 55°C) maximum (113°F (45°C) for standard cell) |
| Gas | Process and non-condensing sample with particles <5 µm |
| Display Type | Backlit LCD |
| O-Ring Material | Viton |
| Hazardous Area Classification | ATEX/IECEx |
| Dimensions | 9.21 x 9.21 x 6.77"; (234 x 234 x 172 mm) |
| Weight | 21.38 lbs (9.7 kg) |
Analyzer
Hazardous Area Certificate
Calibration Certificate