The EM3500 series offers a three-phase DIN rail-mounted energy meter designed for accurate cost allocation and sub-metering with low voltage current transducers, providing ANSI C12.20 accuracy of 0.2%. Suitable for 230V AC networks, these meters are compliant with UL508, CSA 22.2, and EN 61010-1 standards, featuring Native BACnet and pulse inputs for simple wage sensor integration.
The EM3500 series offers a three-phase DIN rail-mounted energy meter designed for accurate cost allocation and sub-metering with low voltage current transducers, providing ANSI C12.20 accuracy of 0.2%. Suitable for 230V AC networks, these meters are compliant with UL508, CSA 22.2, and EN 61010-1 standards, featuring Native BACnet and pulse inputs for simple wage sensor integration.
The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xx models are designed for use with Low Votage Current Transducers 1/3Volt or 1Volt output. Current input from 5A to 32000A, according to the LVCT configuration in the HMI, ANSI C12.20 0.2% accuracy, IEC 62053-22 class 0.2S. Native BACnet is provided to suit a wide variety of applications. Additional 2 pulse inputs provide an easy way to incorporate simple WAGES sensors using a BACnet system. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm.
Features
Measurement Accuracy | |
Real Power & Energy | IEC 62053-22 Class 0.2S,ANSI C12.20 0.2% |
Input Voltage Characteristics | |
Measured AC Voltage | Minimum 90 V L-N (156 V L-L ) for stated accuracy; UL Maximums: 600 VL-L (347 VL-N ); CE Maximum: 300 V L-N |
Impedance | 2.5 MΩ L-N /5 MΩ L-L |
Frequency Range | 45 to 65 Hz |
Input Current Characteristics | |
Measurement Input Range | 0 to 0.333 VAC or 0 to 1.0 VAC (+20% over-range) |
Impedance | 10.6 kΩ (1/3 V mode) or 32.1 kΩ (1 V mode) |
Control Power | |
AC | 5 VA max.; 90 V min. UL Maximums: 600 VL-L (347 VL-N ) CE Maximum: 300 V L-N |
DC | 3 W max.; UL and CE: 125 to 300 VDC |
Ride Through Time | 100 msec at 120 VAC |
Mechanical Characteristics | |
IP Degree of Protection (IEC 60529) | IP40 front display; IP20 Meter |
Terminal Block Screw Torque | 0.37 ft·lb (0.5 N·m) nominal 0.44 ft·lb (0.6 N·m) max. |
Terminal Block Wire Size | 14 to 24 AWG |
Rail | T35 (35 mm) DIN Rail per EN 50022 |
Environmental Conditions | |
Operating Temperature | -30° to 70°C (-22° to 158°F) |
Storage Temperature | -40° to 85°C (-40° to 185°F) |
Humidity Range | <95% RH (non-condensing) |
Altitude of Operation | 3 km max |
Mounting Location | Not suitable for wet locations. For indoor use only. |
Metering Category | |
North America | CAT III; for distribution systems up to 347 V L-N /600 VAC L-L |
CE | CAT III; for distribution systems up to 300 V L-N |
Dielectric Withstand | Per UL 508, IEC/EN 61010-1 |
Conducted and Radiated Emissions | FCC part 15 Class B, EN 55011/ EN 61000 Class B (residential and light industrial) |
Conducted and Radiated Immunity | EN 61000 Class A (heavy industrial) |
Agency Approvals | |
US and Canada (cULus) | UL 508 (open type device)/CSA 22.2 No. 14-05 |
Europe (CE) | IEC/EN 61010-1 |
Measurement Accuracy | |
Real Power & Energy | IEC 62053-22 Class 0.2S,ANSI C12.20 0.2% |
Input Voltage Characteristics | |
Measured AC Voltage | Minimum 90 V L-N (156 V L-L ) for stated accuracy; UL Maximums: 600 VL-L (347 VL-N ); CE Maximum: 300 V L-N |
Impedance | 2.5 MΩ L-N /5 MΩ L-L |
Frequency Range | 45 to 65 Hz |
Input Current Characteristics | |
Measurement Input Range | 0 to 0.333 VAC or 0 to 1.0 VAC (+20% over-range) |
Impedance | 10.6 kΩ (1/3 V mode) or 32.1 kΩ (1 V mode) |
Control Power | |
AC | 5 VA max.; 90 V min. UL Maximums: 600 VL-L (347 VL-N ) CE Maximum: 300 V L-N |
DC | 3 W max.; UL and CE: 125 to 300 VDC |
Ride Through Time | 100 msec at 120 VAC |
Mechanical Characteristics | |
IP Degree of Protection (IEC 60529) | IP40 front display; IP20 Meter |
Terminal Block Screw Torque | 0.37 ft·lb (0.5 N·m) nominal 0.44 ft·lb (0.6 N·m) max. |
Terminal Block Wire Size | 14 to 24 AWG |
Rail | T35 (35 mm) DIN Rail per EN 50022 |
Environmental Conditions | |
Operating Temperature | -30° to 70°C (-22° to 158°F) |
Storage Temperature | -40° to 85°C (-40° to 185°F) |
Humidity Range | <95% RH (non-condensing) |
Altitude of Operation | 3 km max |
Mounting Location | Not suitable for wet locations. For indoor use only. |
Metering Category | |
North America | CAT III; for distribution systems up to 347 V L-N /600 VAC L-L |
CE | CAT III; for distribution systems up to 300 V L-N |
Dielectric Withstand | Per UL 508, IEC/EN 61010-1 |
Conducted and Radiated Emissions | FCC part 15 Class B, EN 55011/ EN 61000 Class B (residential and light industrial) |
Conducted and Radiated Immunity | EN 61000 Class A (heavy industrial) |
Agency Approvals | |
US and Canada (cULus) | UL 508 (open type device)/CSA 22.2 No. 14-05 |
Europe (CE) | IEC/EN 61010-1 |