The PVK350 Photovoltaic Test Kit is an essential toolset for solar professionals involved in the installation, maintenance, monitoring, and testing of photovoltaic systems. It includes the DCM1500S AC/DC solar clamp meter, PVM210 solar irradiance meter and a range of specialist PV test leads, all the tools necessary to efficiently and safely assess and maintain PV systems, ensuring they operate at peak performance.

The PVK350 Photovoltaic Test Kit is an essential toolset for solar professionals involved in the installation, maintenance, monitoring, and testing of photovoltaic systems. It includes the DCM1500S AC/DC solar clamp meter, PVM210 solar irradiance meter and a range of specialist PV test leads, all the tools necessary to efficiently and safely assess and maintain PV systems, ensuring they operate at peak performance.

Regular Price $1218.00 CAD
Availability 2 to 3 Weeks
Quantity

Megger PVK350 Offers

PVM210: The PVM210 Irradiance Meter gives fast, accurate readings of solar power for optimal incident angle and positioning of photovoltaic panels. In addition, the meter can provide vital measurements for the calculation of short circuit current in conjunction with a suitable ammeter to verify the specifications provided by the manufacturer of the panel.

DCM1500S: Designedto be used on electrical systems and equipment, including solar/photovoltaic installations where there is a need to measure current, volts, resistance and frequency, the DCM1500S AC/DC Solar Clamp Meter is intended for use while installing, maintaining, faultfinding or monitoring those systems. The DC current measurement can also be used in applications including battery monitoring, automotive, charging and load circuits, electric vehicle servicing, lift maintenance, UPS commissioning, servicing, and maintenance. Also included are applications involving electro-plating plants and welding equipment servicing as well as power generation from solar panels and wind turbines.

PV Test Leads: ThePVK350 includes a range of specialist PV test leads for complete testing of solar installations. The kit includes the PVHV1 4 mm Connection Test Lead Set and PVHV2 PV Test Lead Set for high voltage testing. Additionally, a standard 4 mm to PV connector lead set is provided together with a PV connector adapter lead set for older panel styles. The PVHV1 and PVHV2 are designed for use on circuits not directly connected to the mains supply.

Features

PVM210

  • Selectable BTU (British Thermal Unit) measurement range In addition to W/m² measurements
  • Easy-to-read 3¾ digit LCD display
  • Measurement hold feature
  • Auto power off prolongs battery life
  • Standard camera mount fixing for accurate placement
  • Protective pouch included

DCM1500S

  • 2000 V DC, 1500 V AC, 1500 A AC/DC
  • True RMS reading on A CA/A CV
  • AC/DC µA Range
  • DC mV Range
  • 6,000 counts LED-backlit display
  • Smart Hold
  • MIN/MAX Hold
  • High frequency rejection filter
  • Inrush current measurement
  • Non-contact volt seek mode
  • Manual DCA zeroing
  • °C/°F temperature function
  • Internal data logging up to 1000 records
  • Megger Link app compatible

Applications

  • Testing and verifying the performance of photovoltaic (PV) installations
  • Troubleshooting PV systems

Megger PVK350 Specifications

VM210
Range 1999 W/m²
634 BTU/(ft²*h)
Accuracy Typically within ±10 W/m²
±3 BTU/(ft²*h)
Resolution 0.1 W/m²
0.1 BTU/(ft²*h)
Display 3¾ digit LCD
Power Supply 2 x AAA, MN2400, LR03
Dimensions 134 x 48 x 27 mm
Weight 90 g (approx.)
DCM1500S
Voltage DC: 1000 V
AC: 1000 V
PV Voltage DC: 2000 V (using PVHV1 or PVHV2 lead sets)
AC: 1500 V (using PVHV1 or PVHV2 lead sets)
DC mV 600.0 mV
AC/DC 4000 µA
1500 A
Resistance 600.0 kΩ
Continuity Buzzer sounds <20 Ω
Buzzer off >200 Ω
(Between 20 to 200 Ω buzzer may be either on or off)
Diode 1.500 V
Frequency 10.000 kHz
Capacitance 1000 µF
Temperature Range -40 to 752°F (-40 to 400°C)
VoltSeek High sensitivity: 80 to 1000 V (at the top edge of the jaw)
Low sensitivity: 160 to 1000 V (at the top edge of the jaw)
PV Test Leads
Leads PVHV1 (4 mm): 2000 V DC / 1500 V AC
1 pair 1.3 meter leads terminated with 4 mm plugs and PV solar connectors

PVHV2 (PV): 2000 V DC / 1500 V AC
1 pair 0.2-metre adapter leads terminated with PV conversion adaptor leads
Maximum Current 19 A
Maximum Voltage 1000 V
Click here for complete specifications on the Megger PVK350

What's included with the Megger PVK350

  • PVM210 Solar Irradiance meter
  • DCM1500S AC/DC Solar Clamp Meter
  • PV HV1 Test Lead Set, 4 mm Plugs
  • PV HV2 Test Lead Set, PV Plugs
  • DCM Standard 4 mm to PV Connector Lead Set
  • PV Connector Adapter Lead Set
  • TP100 Type K Thermocouple Probe
  • Set of Batteries
  • Hard Carrying Case

Ask a question about Megger PVK350 Photovoltaic Test Kit

Customer Reviews for the Megger PVK350

Megger PVK350 Offers

PVM210: The PVM210 Irradiance Meter gives fast, accurate readings of solar power for optimal incident angle and positioning of photovoltaic panels. In addition, the meter can provide vital measurements for the calculation of short circuit current in conjunction with a suitable ammeter to verify the specifications provided by the manufacturer of the panel.

DCM1500S: Designedto be used on electrical systems and equipment, including solar/photovoltaic installations where there is a need to measure current, volts, resistance and frequency, the DCM1500S AC/DC Solar Clamp Meter is intended for use while installing, maintaining, faultfinding or monitoring those systems. The DC current measurement can also be used in applications including battery monitoring, automotive, charging and load circuits, electric vehicle servicing, lift maintenance, UPS commissioning, servicing, and maintenance. Also included are applications involving electro-plating plants and welding equipment servicing as well as power generation from solar panels and wind turbines.

PV Test Leads: ThePVK350 includes a range of specialist PV test leads for complete testing of solar installations. The kit includes the PVHV1 4 mm Connection Test Lead Set and PVHV2 PV Test Lead Set for high voltage testing. Additionally, a standard 4 mm to PV connector lead set is provided together with a PV connector adapter lead set for older panel styles. The PVHV1 and PVHV2 are designed for use on circuits not directly connected to the mains supply.

Features

PVM210

  • Selectable BTU (British Thermal Unit) measurement range In addition to W/m² measurements
  • Easy-to-read 3¾ digit LCD display
  • Measurement hold feature
  • Auto power off prolongs battery life
  • Standard camera mount fixing for accurate placement
  • Protective pouch included

DCM1500S

  • 2000 V DC, 1500 V AC, 1500 A AC/DC
  • True RMS reading on A CA/A CV
  • AC/DC µA Range
  • DC mV Range
  • 6,000 counts LED-backlit display
  • Smart Hold
  • MIN/MAX Hold
  • High frequency rejection filter
  • Inrush current measurement
  • Non-contact volt seek mode
  • Manual DCA zeroing
  • °C/°F temperature function
  • Internal data logging up to 1000 records
  • Megger Link app compatible

Applications

  • Testing and verifying the performance of photovoltaic (PV) installations
  • Troubleshooting PV systems

Megger PVK350 Specifications

VM210
Range 1999 W/m²
634 BTU/(ft²*h)
Accuracy Typically within ±10 W/m²
±3 BTU/(ft²*h)
Resolution 0.1 W/m²
0.1 BTU/(ft²*h)
Display 3¾ digit LCD
Power Supply 2 x AAA, MN2400, LR03
Dimensions 134 x 48 x 27 mm
Weight 90 g (approx.)
DCM1500S
Voltage DC: 1000 V
AC: 1000 V
PV Voltage DC: 2000 V (using PVHV1 or PVHV2 lead sets)
AC: 1500 V (using PVHV1 or PVHV2 lead sets)
DC mV 600.0 mV
AC/DC 4000 µA
1500 A
Resistance 600.0 kΩ
Continuity Buzzer sounds <20 Ω
Buzzer off >200 Ω
(Between 20 to 200 Ω buzzer may be either on or off)
Diode 1.500 V
Frequency 10.000 kHz
Capacitance 1000 µF
Temperature Range -40 to 752°F (-40 to 400°C)
VoltSeek High sensitivity: 80 to 1000 V (at the top edge of the jaw)
Low sensitivity: 160 to 1000 V (at the top edge of the jaw)
PV Test Leads
Leads PVHV1 (4 mm): 2000 V DC / 1500 V AC
1 pair 1.3 meter leads terminated with 4 mm plugs and PV solar connectors

PVHV2 (PV): 2000 V DC / 1500 V AC
1 pair 0.2-metre adapter leads terminated with PV conversion adaptor leads
Maximum Current 19 A
Maximum Voltage 1000 V
Click here for complete specifications on the Megger PVK350

What's included with the Megger PVK350

  • PVM210 Solar Irradiance meter
  • DCM1500S AC/DC Solar Clamp Meter
  • PV HV1 Test Lead Set, 4 mm Plugs
  • PV HV2 Test Lead Set, PV Plugs
  • DCM Standard 4 mm to PV Connector Lead Set
  • PV Connector Adapter Lead Set
  • TP100 Type K Thermocouple Probe
  • Set of Batteries
  • Hard Carrying Case