Megger DLRO200-115 Digital Low Resistance Ohmmeter, 200 A, 115 V

Model: DLRO200-115

Megger DLRO200-115 Digital Low Resistance Ohmmeter, 200 A, 115 V

Model: DLRO200-115

The DLRO200-115 is designed to check and measure contact resistance in high voltage circuit breakers, disconnecting switches (isolators), busbar joints, or for any low resistance measurement. It accurately measures resistances ranging from 0.1 μΩ to 1 Ω, at test currents from 10 A up to 200 A. Extra filtering on the output reduces mains frequency ripple and eliminates magnetic transients that could inductively trip a breaker's control circuit.

The DLRO200-115 is designed to check and measure contact resistance in high voltage circuit breakers, disconnecting switches (isolators), busbar joints, or for any low resistance measurement. It accurately measures resistances ranging from 0.1 μΩ to 1 Ω, at test currents from 10 A up to 200 A. Extra filtering on the output reduces mains frequency ripple and eliminates magnetic transients that could inductively trip a breaker's control circuit.

Regular Price $13990.00 CAD
Availability 7 to 8 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your DLRO200-115 Digital Low Resistance Ohmmeter

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your DLRO200-115 Digital Low Resistance Ohmmeter

Megger DLRO200-115 Offers

The Megger DLRO200-115 measures contact resistance in high voltage circuit breakers, disconnecting switches (isolators), busbar joints, or for any other low resistance measurement. This test set accurately measures resistances ranging from 0.1 µΩ to 1 Ω, at high currents. A versatile instrument, it can provide test currents from 10 amps up to 200 amps, subject to the load resistance and supply voltage. For those applications that demand a smooth dc current, the DLRO200-115 has extra filtering on the output to reduce mains frequency ripple and can drive 200 amps through a total current loop resistance of 11 milliohms. The filtered output also eliminates magnetic transients that could inductively trip a breaker’s control (bus differential relay), if left in the test circuit. The instrument weighs less than 32 lbs. (14.5 kg), and a water/dust ingress rating of IP54 makes the test set equally at home in the workshop, on the production floor or in the field.

Features

  • Small and weighs less than 15 kg (33 lbs)
  • Test currents from 10 A to 200 A DC
  • 0.1 µΩ best resolution
  • On board memory for up to 300 test results and notes
  • RS232 port to download stored results or for real time output to a printer
  • Four terminal measurement cancels the resistance of the test leads
  • Filtered direct current output eliminates magnetic transients

Test Modes

The microhmmeter operates in one of three modes, which are simply selected from the on screen menu.

CONTINUOUS mode is provided for users who wish to monitor a resistance over a period of time. Connect the test leads, select the test current and press the TEST button. It will pass a current continuously, and measure the resulting voltage at 2-second intervals, until the test button is pressed to stop the test or the test circuit is interrupted.

In NORMAL mode you connect the leads, select the test current and press the TEST button. The test current will ramp up to the desired level, hold for two seconds and then ramp down. The whole process takes approximately 10 seconds.

In AUTO mode select the desired current, connect the current leads and press the TEST button. The TEST lamp will flash to show that the microhmmeter is ready to carry out a test. As soon as the potential leads are connected, a test will start. To repeat a test, simply break contact with the voltage probes and remake contact.

Measuring individual joints in a busbar is a good example of the convenience to be gained by using AUTO mode. The two current leads are connected to the ends of the busbar. They will remain connected here until all tests have been completed. When the voltage leads make contact across a joint, it detects that all four leads are connected, carries out a test and stops. When you move to the next joint DLRO detects the new completed circuit automatically and carries out the next test, and so on until all joints have been tested. The results may be stored automatically and may be recalled to the display or downloaded for review.

Applications

  • Home workshops
  • Production floor
  • In the field

Megger DLRO200-115 Specifications

Measurement
Range 0.1 μΩ to 999.9 mΩ (subject to supply voltage and leads used)
General Specifications
Co-Efficient <0.05% per °C
Measurement
Accuracy Voltage ±0.5% ± 0.1 mV
Current ±0.5% ± 0.1 A
Resistance: Better than 1% from 300 μΩ to 100 mΩ
Better than ±2% from 100 to 300 μΩ
Current Lead Resistance 4 mΩ
Maximum Continuous Test Time More than 10 minutes at 200 A and 20°C ambient
Test Modes Manual, Auto, Continuous
Test Time 10 seconds NORMAL/AUTO mode. Refreshed every 2 seconds in CONTINUOUS mode
Test Current
Range 10 to 200 A DC (dependant on load and input voltage)
Accuracy ±2% ±2 A
Voltmeter Input Impedance >200 kΩ
Hum Rejection 5 Vrms 50/60 Hz
General Specifications
Display Large, high resolution backlit liquid crystal display
Warnings Current flowing - LED. Other warnings are shown on the LCD display
Data Transfer Real time or batch download via RS232 using Download Manager
Storage Capacity 300 result sets and memo, battery backed for 10 years
Memo Field 160 characters maximum
Temperature Operating: -14 to 122°F (-10 to 50°C)
Storage: -13 to 149°F (-25 to 65°C)
Calibration 20°C
Maximum Humidity 95% RH non-condensing
Maximum Altitude 6561.68' (2000 m)
Safety IEC61010-1
EMC IEC61326-1
Dimensions 16.4 x 9.84 x 10.63" (410 x 250 x 270 mm)
Weight 31.97 lbs (14.5 kg), excluding test leads
Click here for complete specifications on the Megger DLRO200-115

What's included with the Megger DLRO200-115

  • Microhmmeter
  • Lead Set:
    • 2 x Current Leads with Clips
    • 2 x Potential Leads with Clips
  • RS232 Download Cable
  • Download Manager
  • User Guide on CD-ROM
  • Quick Start Guide (English)
  • Warranty Card

Click on a category to view a selection of compatible accessories with the Megger DLRO200-115 Digital Low Resistance Ohmmeter, 200 A, 115 V.

Megger 6220-756 Lead Set (10m), Two Current Leads, Two Potential Leads 6220-756
Lead set consists of pair of flexible high current capacity (600 A cont.) leads, together with a separate pair of light-weight potential leads. Suitable for Megger DLRO200, and DLRO600 Micro-Ohmmeters.




Megger 6220-757 Lead Set (15m), Two Current Leads, Two Potential Leads 6220-757
Lead set consists of pair of flexible high current capacity (600 A cont.) leads, together with a separate pair of light-weight potential leads. Suitable for Megger DLRO200, and DLRO600 Micro-Ohmmeters.




Ask a question about Megger DLRO200-115 Digital Low Resistance Ohmmeter, 200 A, 115 V

Customer Reviews for the Megger DLRO200-115

Megger DLRO200-115 Offers

The Megger DLRO200-115 measures contact resistance in high voltage circuit breakers, disconnecting switches (isolators), busbar joints, or for any other low resistance measurement. This test set accurately measures resistances ranging from 0.1 µΩ to 1 Ω, at high currents. A versatile instrument, it can provide test currents from 10 amps up to 200 amps, subject to the load resistance and supply voltage. For those applications that demand a smooth dc current, the DLRO200-115 has extra filtering on the output to reduce mains frequency ripple and can drive 200 amps through a total current loop resistance of 11 milliohms. The filtered output also eliminates magnetic transients that could inductively trip a breaker’s control (bus differential relay), if left in the test circuit. The instrument weighs less than 32 lbs. (14.5 kg), and a water/dust ingress rating of IP54 makes the test set equally at home in the workshop, on the production floor or in the field.

Features

  • Small and weighs less than 15 kg (33 lbs)
  • Test currents from 10 A to 200 A DC
  • 0.1 µΩ best resolution
  • On board memory for up to 300 test results and notes
  • RS232 port to download stored results or for real time output to a printer
  • Four terminal measurement cancels the resistance of the test leads
  • Filtered direct current output eliminates magnetic transients

Test Modes

The microhmmeter operates in one of three modes, which are simply selected from the on screen menu.

CONTINUOUS mode is provided for users who wish to monitor a resistance over a period of time. Connect the test leads, select the test current and press the TEST button. It will pass a current continuously, and measure the resulting voltage at 2-second intervals, until the test button is pressed to stop the test or the test circuit is interrupted.

In NORMAL mode you connect the leads, select the test current and press the TEST button. The test current will ramp up to the desired level, hold for two seconds and then ramp down. The whole process takes approximately 10 seconds.

In AUTO mode select the desired current, connect the current leads and press the TEST button. The TEST lamp will flash to show that the microhmmeter is ready to carry out a test. As soon as the potential leads are connected, a test will start. To repeat a test, simply break contact with the voltage probes and remake contact.

Measuring individual joints in a busbar is a good example of the convenience to be gained by using AUTO mode. The two current leads are connected to the ends of the busbar. They will remain connected here until all tests have been completed. When the voltage leads make contact across a joint, it detects that all four leads are connected, carries out a test and stops. When you move to the next joint DLRO detects the new completed circuit automatically and carries out the next test, and so on until all joints have been tested. The results may be stored automatically and may be recalled to the display or downloaded for review.

Applications

  • Home workshops
  • Production floor
  • In the field

Megger DLRO200-115 Specifications

Measurement
Range 0.1 μΩ to 999.9 mΩ (subject to supply voltage and leads used)
General Specifications
Co-Efficient <0.05% per °C
Measurement
Accuracy Voltage ±0.5% ± 0.1 mV
Current ±0.5% ± 0.1 A
Resistance: Better than 1% from 300 μΩ to 100 mΩ
Better than ±2% from 100 to 300 μΩ
Current Lead Resistance 4 mΩ
Maximum Continuous Test Time More than 10 minutes at 200 A and 20°C ambient
Test Modes Manual, Auto, Continuous
Test Time 10 seconds NORMAL/AUTO mode. Refreshed every 2 seconds in CONTINUOUS mode
Test Current
Range 10 to 200 A DC (dependant on load and input voltage)
Accuracy ±2% ±2 A
Voltmeter Input Impedance >200 kΩ
Hum Rejection 5 Vrms 50/60 Hz
General Specifications
Display Large, high resolution backlit liquid crystal display
Warnings Current flowing - LED. Other warnings are shown on the LCD display
Data Transfer Real time or batch download via RS232 using Download Manager
Storage Capacity 300 result sets and memo, battery backed for 10 years
Memo Field 160 characters maximum
Temperature Operating: -14 to 122°F (-10 to 50°C)
Storage: -13 to 149°F (-25 to 65°C)
Calibration 20°C
Maximum Humidity 95% RH non-condensing
Maximum Altitude 6561.68' (2000 m)
Safety IEC61010-1
EMC IEC61326-1
Dimensions 16.4 x 9.84 x 10.63" (410 x 250 x 270 mm)
Weight 31.97 lbs (14.5 kg), excluding test leads
Click here for complete specifications on the Megger DLRO200-115

What's included with the Megger DLRO200-115

  • Microhmmeter
  • Lead Set:
    • 2 x Current Leads with Clips
    • 2 x Potential Leads with Clips
  • RS232 Download Cable
  • Download Manager
  • User Guide on CD-ROM
  • Quick Start Guide (English)
  • Warranty Card

Click on a category to view a selection of compatible accessories with the Megger DLRO200-115 Digital Low Resistance Ohmmeter, 200 A, 115 V.

Megger 6220-756 Lead Set (10m), Two Current Leads, Two Potential Leads 6220-756
Lead set consists of pair of flexible high current capacity (600 A cont.) leads, together with a separate pair of light-weight potential leads. Suitable for Megger DLRO200, and DLRO600 Micro-Ohmmeters.




Megger 6220-757 Lead Set (15m), Two Current Leads, Two Potential Leads 6220-757
Lead set consists of pair of flexible high current capacity (600 A cont.) leads, together with a separate pair of light-weight potential leads. Suitable for Megger DLRO200, and DLRO600 Micro-Ohmmeters.




Ask a question about Megger DLRO200-115 Digital Low Resistance Ohmmeter, 200 A, 115 V

Customer Reviews for the Megger DLRO200-115