KANE988 Industrial Boiler & Heat Pump Analyzer with KANE LINK

Model: KANE988 | UPC: 053533900231

KANE988 Industrial Boiler & Heat Pump Analyzer with KANE LINK

Model: KANE988 | UPC: 053533900231

KANE988 analyzers offer several options to custom equip it to your individual needs. Due to the customization, you can order this analyzer using the following step-by-step guide.

KANE988 analyzers offer several options to custom equip it to your individual needs. Due to the customization, you can order this analyzer using the following step-by-step guide.

Sale Price $4899.95 CAD
Regular Price $4999.95 CAD
Availability 6 to 7 Weeks
Quantity

Kane KANE988 Offers

The KANE988 analyzer can be tailored to meet your specific requirements, offering a range of customizable options. To ensure you receive a unit configured to your needs, simply follow the step-by-step ordering guide. All sensors are professionally installed at our ISO-certified laboratory in Indianapolis, IN.

Features

  • Up to 10 Year warranty with annual recertification
  • Eligible for UEi Service+
  • LINK capability to wireless probes
  • NOx filtered & H2 Compensated CO sensor
  • Low Flow Detection to protect reading accuracy
  • Large graphic color display
  • Protective water trap with water stop filter using hydrophobic technology to stopwater vapor
  • Wireless connection to a Free Printer App(iOS® and Android™ Compatible)
  • 2200 memory positions
  • Protective Boot with built-in magnet and hand grip
  • 15 pre-programmed fuels
  • 5 User defined fuels

Applications

  • Install, commission & service any heating & hot water system using any fossil, biomass & HVO fuel
  • Optional environmental sensors test to local regulations
  • Accurate NO2 & SO2 measurements with optional KANE-GCU gas conditioning unit
  • Safety checks - CO in rooms & around appliances
  • Combustion performance & efficiency tests
  • Flue draft & gas pressure / system tightness tests
  • Flow & return, air flow & air quality tests

Kane KANE988 Specifications

Flue & Inlet Temperature External sensor -50 - 1200°C
Inlet Temperature Internal sensor 0-50°C
Oxygen, O2 0 - 25%
Carbon Monoxide, CO H2 Compensated 0 - 10,000ppm | 10,000 - 100,000ppm
Carbon Monoxide, High Range NDIR 0 - 10%
Carbon Dioxide, NDIR 0 - 20%
Hydrocarbon, NDIR 0 - 5000ppm | Over-range: 10,000ppm
Nitric Oxide, NO (optional) 0 - 5000ppm
Nitrogen Dioxide, NO2 (optional) 0 - 1000ppm
Sulphur Dioxide, SO2 (optional) 0 - 5000ppm
Hydrogen Sulphide, H2S (optional) 0 - 200ppm
Pressure (Differential) ±160mbar
Click here for complete specifications on the Kane KANE988

What's included with the Kane KANE988

  • KANE988 Industrial Boiler & Heat Pump Analyzer with KANE LINK

Ask a question about KANE988 Industrial Boiler & Heat Pump Analyzer with KANE LINK

Customer Reviews for the Kane KANE988

Kane KANE988 Offers

The KANE988 analyzer can be tailored to meet your specific requirements, offering a range of customizable options. To ensure you receive a unit configured to your needs, simply follow the step-by-step ordering guide. All sensors are professionally installed at our ISO-certified laboratory in Indianapolis, IN.

Features

  • Up to 10 Year warranty with annual recertification
  • Eligible for UEi Service+
  • LINK capability to wireless probes
  • NOx filtered & H2 Compensated CO sensor
  • Low Flow Detection to protect reading accuracy
  • Large graphic color display
  • Protective water trap with water stop filter using hydrophobic technology to stopwater vapor
  • Wireless connection to a Free Printer App(iOS® and Android™ Compatible)
  • 2200 memory positions
  • Protective Boot with built-in magnet and hand grip
  • 15 pre-programmed fuels
  • 5 User defined fuels

Applications

  • Install, commission & service any heating & hot water system using any fossil, biomass & HVO fuel
  • Optional environmental sensors test to local regulations
  • Accurate NO2 & SO2 measurements with optional KANE-GCU gas conditioning unit
  • Safety checks - CO in rooms & around appliances
  • Combustion performance & efficiency tests
  • Flue draft & gas pressure / system tightness tests
  • Flow & return, air flow & air quality tests

Kane KANE988 Specifications

Flue & Inlet Temperature External sensor -50 - 1200°C
Inlet Temperature Internal sensor 0-50°C
Oxygen, O2 0 - 25%
Carbon Monoxide, CO H2 Compensated 0 - 10,000ppm | 10,000 - 100,000ppm
Carbon Monoxide, High Range NDIR 0 - 10%
Carbon Dioxide, NDIR 0 - 20%
Hydrocarbon, NDIR 0 - 5000ppm | Over-range: 10,000ppm
Nitric Oxide, NO (optional) 0 - 5000ppm
Nitrogen Dioxide, NO2 (optional) 0 - 1000ppm
Sulphur Dioxide, SO2 (optional) 0 - 5000ppm
Hydrogen Sulphide, H2S (optional) 0 - 200ppm
Pressure (Differential) ±160mbar
Click here for complete specifications on the Kane KANE988

What's included with the Kane KANE988

  • KANE988 Industrial Boiler & Heat Pump Analyzer with KANE LINK

Ask a question about KANE988 Industrial Boiler & Heat Pump Analyzer with KANE LINK

Customer Reviews for the Kane KANE988

More Kane Products