Kane KANE458S Flue Gas Analyzer with direct CO, CO2 and CO sensor protection

Model: KANE458S

Kane KANE458S Flue Gas Analyzer with direct CO, CO2 and CO sensor protection

Model: KANE458S

Capable of testing domestic gas, oil, biomass, and some commercial appliances, this flue gas analyzer has direct sensor protection and comes with the latest upgradeable sensor technology. In addition, it has a protective rubber cover with magnets for hands-free operation.

Capable of testing domestic gas, oil, biomass, and some commercial appliances, this flue gas analyzer has direct sensor protection and comes with the latest upgradeable sensor technology. In addition, it has a protective rubber cover with magnets for hands-free operation.

Sale Price $2155.95 CAD
Regular Price $2199.95 CAD
Availability 1 to 2 Weeks
Quantity

Kane KANE458S Offers

The Kane 458S Flue Gas Analyser is an ergonomically designed FGA with direct carbon monoxide (CO) and carbon dioxide (CO2) measurement, carbon monoxide and carbon dioxide sensor protection, and an integrated wireless module. In addition to measuring the aforementioned gases (model dependent), the Kane 458S Flue Gas Analysers is abe to determine differential temperatures and can calculate oxygen (O2), CO: CO2 ratio, excess air and combustion efficiency. Moreover, the Kane 458S Flue Gas Analysers include a structured commissioning test (for certifying new boilers according to Technical Bulletin 143) and are equipped with a high-accuracy differential pressure meter (+/- 80mbar).

The Kane 458S Flue Gas Analysers also feature a Log and Print function that facilitates wireless printing of pressure, let-by and tightness, combustion, temperature, CO build-up, and commission test reports. Reports with the user's details can be sent to print wirelessly using an OPTIONAL Kane IRP-2 Infrared Printer. The inclusion of a wireless module also facilitates communication between the Kane 458S Flue Gas Analysers and Kane's Gas Checker and Kane Live apps.

In addition to Log and Print functions, the Kane 458S Flue Gas Analysers include a Data Hold function which will freeze the readings on the six-line display. All the Kane 458S Flue Gas Analysers' measurement functions and parameters are easily accessible using a rotary dial. Finally, the Kane 458S Flue Gas Analysers are Hydrogen (H2) ready (up to 20%) and are compatible with the following fuel types: natural gas, butane, LPG, light oil, wood pellets and propane.

Features

  • Ergonomically designed FGA
  • Direct carbon monoxide (CO) and carbon dioxide (CO2) measurements
  • Carbon monoxide and carbon dioxide sensor protection
  • Integrated wireless module
  • Five versions available with different sensor combinations (see the table above)
  • Latest upgradeable sensor technology
  • Purge pump protection to prevent accidental damage to the CO sensor
  • Measure differential pressure
  • Calculate oxygen (O2)
  • Calculate CO: CO2 ratio
  • Calculate excess air
  • Calculate combustion efficiency
  • High-accuracy differential pressure meter (+/- 80mbar)
  • Log and Print function: send reports to print wirelessly (OPTIONAL printer sold separately)
  • Create and print pressure, let-by and tightness, combustion, temperature, CO build-up, and commission test reports
  • The wireless module enables communication with the Kane Gas Checker and Kane Live apps
  • Hydrogen (H2) ready: Up to 20%
  • Compatible with natural gas, butane, LPG, light oil, wood pellets and propane
  • Test domestic gas, oil, biomass and some commercial appliances
  • Install and service domestic oil and gas appliances
  • Safety checks (measure the CO in rooms and around appliances)
  • Combustion performance checks
  • Combustion efficiency checks
  • Flue draught
  • An easy-to-use and ergonomic FGA with an eclectic range of applications

Kane KANE458S Specifications

Measures CO2: Direct with an infra-red sensor 0 to 20%
CO: 0 to 2000 ppm
O2: 0 to 21% (option)
NO: 0 to 600 ppm (option)
High range CO: 0 to 10,000 ppm (option)
Differential temperature
High accuracy differential pressure meter ±80 mbar
Calculates O2
CO/CO2 ratio
Excess air
Combustion efficiency
Fuel Types Natural gas, LPG, wood pellets, butane, light oil, propane
Battery Life >8 hours (continuous with pump on)
Operating Conditions Temperatures: 32 to 113°F (0 to 45°C)
Humidity: 15 to 90% RH, (non-condensing)
Power Supply Rechargeable batteries, USB charging
Dimensions 8.5 x 4.13 x 1.77" (216 x 105 x 45 mm)
Weight Approximately 0.0014 lbs (0.625 g)
Click here for complete specifications on the Kane KANE458S

What's included with the Kane KANE458S

  • Flue Gas Analyser
  • Probe
  • Pressure Connectors
  • Charger
  • Quick Reference Guide
  • Calibration Certificate

Click on a category to view a selection of compatible accessories with the Kane KANE458S Flue Gas Analyzer with direct CO, CO2 and CO sensor protection.

Kane CP2S Flue Probe for the KANE258/358/458s/457/958/988, 3.94" CP2S
Compatible with KANE258/358/458s/457/958/988 flue gas analyzers, this flue probe has a length of 3.94" (100 mm) with a molded handle and a shaft diameter of 0.24" (6 mm). In addition, it comes with a 39.37" (1000 mm) long hose.




Kane CP2T PTFE Lined Probe for the KANE258/358/458s/457/958/988, 11.22" CP2T
Compatible with the KANE258/358/458s/457/958/988 flue gas analyzers, this PTFE-lined probe has 0.31" (8 mm) diameter and comes with a 9.84" (3 m) neoprene hose. In addition, it has a shaft length of 11.22" (285 mm).




Kane SM14980 Flue Gas Probe Connector for the KANE258/358/458s/457/958/988 SM14980
Intended for use as a replacement, this flue gas probe connector is compatible with KANE258/358/458s/457/958/988 flue gas analyzers.




Ask a question about Kane KANE458S Flue Gas Analyzer with direct CO, CO2 and CO sensor protection

Customer Reviews for the Kane KANE458S

Kane KANE458S Offers

The Kane 458S Flue Gas Analyser is an ergonomically designed FGA with direct carbon monoxide (CO) and carbon dioxide (CO2) measurement, carbon monoxide and carbon dioxide sensor protection, and an integrated wireless module. In addition to measuring the aforementioned gases (model dependent), the Kane 458S Flue Gas Analysers is abe to determine differential temperatures and can calculate oxygen (O2), CO: CO2 ratio, excess air and combustion efficiency. Moreover, the Kane 458S Flue Gas Analysers include a structured commissioning test (for certifying new boilers according to Technical Bulletin 143) and are equipped with a high-accuracy differential pressure meter (+/- 80mbar).

The Kane 458S Flue Gas Analysers also feature a Log and Print function that facilitates wireless printing of pressure, let-by and tightness, combustion, temperature, CO build-up, and commission test reports. Reports with the user's details can be sent to print wirelessly using an OPTIONAL Kane IRP-2 Infrared Printer. The inclusion of a wireless module also facilitates communication between the Kane 458S Flue Gas Analysers and Kane's Gas Checker and Kane Live apps.

In addition to Log and Print functions, the Kane 458S Flue Gas Analysers include a Data Hold function which will freeze the readings on the six-line display. All the Kane 458S Flue Gas Analysers' measurement functions and parameters are easily accessible using a rotary dial. Finally, the Kane 458S Flue Gas Analysers are Hydrogen (H2) ready (up to 20%) and are compatible with the following fuel types: natural gas, butane, LPG, light oil, wood pellets and propane.

Features

  • Ergonomically designed FGA
  • Direct carbon monoxide (CO) and carbon dioxide (CO2) measurements
  • Carbon monoxide and carbon dioxide sensor protection
  • Integrated wireless module
  • Five versions available with different sensor combinations (see the table above)
  • Latest upgradeable sensor technology
  • Purge pump protection to prevent accidental damage to the CO sensor
  • Measure differential pressure
  • Calculate oxygen (O2)
  • Calculate CO: CO2 ratio
  • Calculate excess air
  • Calculate combustion efficiency
  • High-accuracy differential pressure meter (+/- 80mbar)
  • Log and Print function: send reports to print wirelessly (OPTIONAL printer sold separately)
  • Create and print pressure, let-by and tightness, combustion, temperature, CO build-up, and commission test reports
  • The wireless module enables communication with the Kane Gas Checker and Kane Live apps
  • Hydrogen (H2) ready: Up to 20%
  • Compatible with natural gas, butane, LPG, light oil, wood pellets and propane
  • Test domestic gas, oil, biomass and some commercial appliances
  • Install and service domestic oil and gas appliances
  • Safety checks (measure the CO in rooms and around appliances)
  • Combustion performance checks
  • Combustion efficiency checks
  • Flue draught
  • An easy-to-use and ergonomic FGA with an eclectic range of applications

Kane KANE458S Specifications

Measures CO2: Direct with an infra-red sensor 0 to 20%
CO: 0 to 2000 ppm
O2: 0 to 21% (option)
NO: 0 to 600 ppm (option)
High range CO: 0 to 10,000 ppm (option)
Differential temperature
High accuracy differential pressure meter ±80 mbar
Calculates O2
CO/CO2 ratio
Excess air
Combustion efficiency
Fuel Types Natural gas, LPG, wood pellets, butane, light oil, propane
Battery Life >8 hours (continuous with pump on)
Operating Conditions Temperatures: 32 to 113°F (0 to 45°C)
Humidity: 15 to 90% RH, (non-condensing)
Power Supply Rechargeable batteries, USB charging
Dimensions 8.5 x 4.13 x 1.77" (216 x 105 x 45 mm)
Weight Approximately 0.0014 lbs (0.625 g)
Click here for complete specifications on the Kane KANE458S

What's included with the Kane KANE458S

  • Flue Gas Analyser
  • Probe
  • Pressure Connectors
  • Charger
  • Quick Reference Guide
  • Calibration Certificate

Click on a category to view a selection of compatible accessories with the Kane KANE458S Flue Gas Analyzer with direct CO, CO2 and CO sensor protection.

Kane CP2S Flue Probe for the KANE258/358/458s/457/958/988, 3.94" CP2S
Compatible with KANE258/358/458s/457/958/988 flue gas analyzers, this flue probe has a length of 3.94" (100 mm) with a molded handle and a shaft diameter of 0.24" (6 mm). In addition, it comes with a 39.37" (1000 mm) long hose.




Kane CP2T PTFE Lined Probe for the KANE258/358/458s/457/958/988, 11.22" CP2T
Compatible with the KANE258/358/458s/457/958/988 flue gas analyzers, this PTFE-lined probe has 0.31" (8 mm) diameter and comes with a 9.84" (3 m) neoprene hose. In addition, it has a shaft length of 11.22" (285 mm).




Kane SM14980 Flue Gas Probe Connector for the KANE258/358/458s/457/958/988 SM14980
Intended for use as a replacement, this flue gas probe connector is compatible with KANE258/358/458s/457/958/988 flue gas analyzers.




Ask a question about Kane KANE458S Flue Gas Analyzer with direct CO, CO2 and CO sensor protection

Customer Reviews for the Kane KANE458S

More Kane Products