Instek LCR-8105G 20Hz to 5MHz Precision LCR Meter

Model: LCR-8105G

Instek LCR-8105G 20Hz to 5MHz Precision LCR Meter

Model: LCR-8105G

Meter with test frequency up to 10MHz. Provides accuracy, versatility and high resolution for a wide range of component measurements including DC resistance measurement and voltage/current monitoring.

Meter with test frequency up to 10MHz. Provides accuracy, versatility and high resolution for a wide range of component measurements including DC resistance measurement and voltage/current monitoring.

Sale Price $17742.20 CAD
Regular Price $18676.00 CAD
Availability 3 to 4 Weeks
Quantity

GW Instek LCR-8105G Offers

Designed to perform precision impedance measurements over a wide frequency range, the Instek LCR-8105G Precision LCR Meter is capable of measuring eleven different parameters.

Features

  • Test Frequency 20Mhz to 5MHz
  • Large LCD Display
  • 6 digit measurement resolution
  • 0.1% basic measurement resolution
  • Multiple step mode
  • DC resistance measurement
  • Comprehensive measurement functions
  • Monitoring of DUT Voltage and Current
  • Pass/Fail Test
  • Standard Interface: RS-232 and GPIB
  • Graph Mode

GW Instek LCR-8105G Specifications

Test Speed
AC (>2kHz) MAX: 75mS
FAST: 150mS
MEDIUM: 450mS
SLOW: 600mS DC
MAX: 30mS
FAST: 60mS
MEDIUM: 120mS
SLOW: 900mS
DC MAX: 30mS
FAST: 60mS
MEDIUM: 120mS
SLOW: 900mS
General Specifications
Test Frequency 20Hz to 10 / 5 / 1 MHz, 5 Digits, ±0.005%
Input Impedence 100Ω
Basic Accuracy ±0.1% (R, Z, X, G, Y, B, L, C)
Test Signal Levels ≤3MHz: 10mV to 2Vrms, 1mV/Step or 10mV/Step, 2%±5mV
>3MHz: 10mV to 1Vrms, 1mV/Step or 10mV/Step, 2%±5mV
Short Circuit Current Max. 20mA
Measurement Ranges R, Z, X: 0.1mΩ to 100MΩ
G, Y, B: 10nS to 1000S
L: 0.1nH to 100kH
C: 0.01pF to 1F
D: 0.00001 to 9.9999
Q: 0.1 to 9999.9
θ: -180 to 180°
Rdc: 0.1mΩ to 100MΩ
Measurement Parameters Impedance: Z
Phase Angle: θ
Inductance: L
Capacitance: C
AC Resistance: Rac
Quality Factor: Q
Dissipation Factor: D
Admittance: Y
Conductance: G
Reactance: X
Susceptance: B
DC Resistance: Rdc
Series or Parallel Equivalent Circuit C + R, C + D, C + Q, L + R, L + Q, L + D
Series Equivalent Circuit Only X + R, X + D, X + Q
Parallel Equivalent Circuit Only C + G, B + G, B + D, B + Q, B + R, L + G
Polar Form Z + Phase Angle, Y + Phase Angle
Average 1 to 256 Times
LCD Display 320 x 240 Dot-Matrix
Interface RS-232, GPIB
Power Source AC 115V(+10% / -25%), 230V(+15% / -14%) (Selectable), 50/60Hz
Dimensions 330 x 170 x 340 mm
Weight Approx. 5kg
Click here for complete specifications on the GW Instek LCR-8105G

What's included with the GW Instek LCR-8105G

  • Precision LCR Meter
  • User Manual
  • Power Cord
  • LCR-12

Ask a question about Instek LCR-8105G 20Hz to 5MHz Precision LCR Meter

Customer Reviews for the GW Instek LCR-8105G

GW Instek LCR-8105G Offers

Designed to perform precision impedance measurements over a wide frequency range, the Instek LCR-8105G Precision LCR Meter is capable of measuring eleven different parameters.

Features

  • Test Frequency 20Mhz to 5MHz
  • Large LCD Display
  • 6 digit measurement resolution
  • 0.1% basic measurement resolution
  • Multiple step mode
  • DC resistance measurement
  • Comprehensive measurement functions
  • Monitoring of DUT Voltage and Current
  • Pass/Fail Test
  • Standard Interface: RS-232 and GPIB
  • Graph Mode

GW Instek LCR-8105G Specifications

Test Speed
AC (>2kHz) MAX: 75mS
FAST: 150mS
MEDIUM: 450mS
SLOW: 600mS DC
MAX: 30mS
FAST: 60mS
MEDIUM: 120mS
SLOW: 900mS
DC MAX: 30mS
FAST: 60mS
MEDIUM: 120mS
SLOW: 900mS
General Specifications
Test Frequency 20Hz to 10 / 5 / 1 MHz, 5 Digits, ±0.005%
Input Impedence 100Ω
Basic Accuracy ±0.1% (R, Z, X, G, Y, B, L, C)
Test Signal Levels ≤3MHz: 10mV to 2Vrms, 1mV/Step or 10mV/Step, 2%±5mV
>3MHz: 10mV to 1Vrms, 1mV/Step or 10mV/Step, 2%±5mV
Short Circuit Current Max. 20mA
Measurement Ranges R, Z, X: 0.1mΩ to 100MΩ
G, Y, B: 10nS to 1000S
L: 0.1nH to 100kH
C: 0.01pF to 1F
D: 0.00001 to 9.9999
Q: 0.1 to 9999.9
θ: -180 to 180°
Rdc: 0.1mΩ to 100MΩ
Measurement Parameters Impedance: Z
Phase Angle: θ
Inductance: L
Capacitance: C
AC Resistance: Rac
Quality Factor: Q
Dissipation Factor: D
Admittance: Y
Conductance: G
Reactance: X
Susceptance: B
DC Resistance: Rdc
Series or Parallel Equivalent Circuit C + R, C + D, C + Q, L + R, L + Q, L + D
Series Equivalent Circuit Only X + R, X + D, X + Q
Parallel Equivalent Circuit Only C + G, B + G, B + D, B + Q, B + R, L + G
Polar Form Z + Phase Angle, Y + Phase Angle
Average 1 to 256 Times
LCD Display 320 x 240 Dot-Matrix
Interface RS-232, GPIB
Power Source AC 115V(+10% / -25%), 230V(+15% / -14%) (Selectable), 50/60Hz
Dimensions 330 x 170 x 340 mm
Weight Approx. 5kg
Click here for complete specifications on the GW Instek LCR-8105G

What's included with the GW Instek LCR-8105G

  • Precision LCR Meter
  • User Manual
  • Power Cord
  • LCR-12

Ask a question about Instek LCR-8105G 20Hz to 5MHz Precision LCR Meter

Customer Reviews for the GW Instek LCR-8105G

More GW Instek Products