INOR LCD-H11X Loop Powered Field Indicator for installation directly in a 4-20 mA loop without the need for external power

Model: LCD-H11X | Order No: 70LCDH11X

INOR LCD-H11X Loop Powered Field Indicator for installation directly in a 4-20 mA loop without the need for external power

Model: LCD-H11X | Order No: 70LCDH11X

This indicator supports HART and uses a rugged body with IP66 water and dust resistance.

This indicator supports HART and uses a rugged body with IP66 water and dust resistance.

Your Price $596.00 CAD
Availability 2 to 3 Weeks
Quantity

INOR LCD-H11X Offers

The INOR LCD-H11X is a digital, heavy-duty LCD indicator for installation directly in a 4-20 mA loop without need for external power.

The indicator is equipped with high-contrast, easy-to-read LCD digits. The scale is easily programmable, without reference signal, by three push buttons for any values between - 1999 and 9999.

Features

  • HART transparent
  • Designed for ambient temperatures between -13 to 158°F (-25 to 70°C)
  • Field mounting in rugged IP 66 / NEMA 4X housing
  • 90° indexing of display orientation
  • Can be used with any DIN B transmitter or as display only
  • Installation directly in a 4-20 mA loop without need for power supply
  • Only 1.5 V voltage drop
  • High-contrast, 4-digit LCD display
  • Simple push button scaling without reference signal
  • Any range between -1999 to 9999 for 4 to 20 mA input
  • Labels for different engineering units are included
  • Typical accuracy of 0.05% allows for high precision read-outs

INOR LCD-H11X Specifications

Input Current 4-20 mA
Maximum Current 30 mA
Minimum Current for Operation ~3.5 mA
Voltage Drop ~1.5 V
Indication
Display Black LCD with 4 digits including minus sign
Digit Height 0.5" (12.7 mm)
Indication Range Any range between -1999 to 9999
Decimals Selectable, 0 to 3
Under Range and Over Range Flashing symbols LO/HI
Engineering Units Set of labels included (including blanks)
Response Time Appr. 0.5 s
Scale Setting 3 pushbuttons inside the housing
Operation Temperature -13 to 158°F (-25 to 70°C)
Typical Accuracy ±0.05% FS ±1 digit
Connections Stranded, ≤ 0.06" (1.5 mm)², AWG 16
Enclosure
Material Pressure Die Cast Aluminium
Silicone Rubber gasket
Glass window
Paint Spray Epoxy Primer with Polyurethane Top Coat
Color: RAL 5005 Signal Blue
Protection NEMA 4X / IP66
FM/CSA Class 1, Div 1 and 2
[FM Cert 3019264] [CSA Cert 1717515]
Conduit Connections 3 x 0.75" (76.2 x 19.05 mm) NPT Threaded ports
Mounting Wall mount or optional 2" (50.8 mm) Conduit 316 SS bar clamp
Click here for complete specifications on the INOR LCD-H11X

What's included with the INOR LCD-H11X

  • INOR LCD-H11X Loop Powered Field Indicator for installation directly in a 4-20 mA loop without the need for external power

Ask a question about INOR LCD-H11X Loop Powered Field Indicator for installation directly in a 4-20 mA loop without the need for external power

Customer Reviews for the INOR LCD-H11X

INOR LCD-H11X Offers

The INOR LCD-H11X is a digital, heavy-duty LCD indicator for installation directly in a 4-20 mA loop without need for external power.

The indicator is equipped with high-contrast, easy-to-read LCD digits. The scale is easily programmable, without reference signal, by three push buttons for any values between - 1999 and 9999.

Features

  • HART transparent
  • Designed for ambient temperatures between -13 to 158°F (-25 to 70°C)
  • Field mounting in rugged IP 66 / NEMA 4X housing
  • 90° indexing of display orientation
  • Can be used with any DIN B transmitter or as display only
  • Installation directly in a 4-20 mA loop without need for power supply
  • Only 1.5 V voltage drop
  • High-contrast, 4-digit LCD display
  • Simple push button scaling without reference signal
  • Any range between -1999 to 9999 for 4 to 20 mA input
  • Labels for different engineering units are included
  • Typical accuracy of 0.05% allows for high precision read-outs

INOR LCD-H11X Specifications

Input Current 4-20 mA
Maximum Current 30 mA
Minimum Current for Operation ~3.5 mA
Voltage Drop ~1.5 V
Indication
Display Black LCD with 4 digits including minus sign
Digit Height 0.5" (12.7 mm)
Indication Range Any range between -1999 to 9999
Decimals Selectable, 0 to 3
Under Range and Over Range Flashing symbols LO/HI
Engineering Units Set of labels included (including blanks)
Response Time Appr. 0.5 s
Scale Setting 3 pushbuttons inside the housing
Operation Temperature -13 to 158°F (-25 to 70°C)
Typical Accuracy ±0.05% FS ±1 digit
Connections Stranded, ≤ 0.06" (1.5 mm)², AWG 16
Enclosure
Material Pressure Die Cast Aluminium
Silicone Rubber gasket
Glass window
Paint Spray Epoxy Primer with Polyurethane Top Coat
Color: RAL 5005 Signal Blue
Protection NEMA 4X / IP66
FM/CSA Class 1, Div 1 and 2
[FM Cert 3019264] [CSA Cert 1717515]
Conduit Connections 3 x 0.75" (76.2 x 19.05 mm) NPT Threaded ports
Mounting Wall mount or optional 2" (50.8 mm) Conduit 316 SS bar clamp
Click here for complete specifications on the INOR LCD-H11X

What's included with the INOR LCD-H11X

  • INOR LCD-H11X Loop Powered Field Indicator for installation directly in a 4-20 mA loop without the need for external power

Ask a question about INOR LCD-H11X Loop Powered Field Indicator for installation directly in a 4-20 mA loop without the need for external power

Customer Reviews for the INOR LCD-H11X

More INOR Products