Hioki VT1005 High Voltage Divider, AC/DC

Model: VT1005

Hioki VT1005 High Voltage Divider, AC/DC

Model: VT1005

Inverters used in rail and power system applications convert high-voltage power. To measure the efficiency of such conversions, it’s necessary to measure voltages of 1000 V and above. The VT1005 divides voltages of up to 5000 V and outputs them to a power analyzer. In order to measure the efficiency of high-efficiency inverters with a high degree of precision, you need to be able to accurately measure power from DC to high frequencies.

Inverters used in rail and power system applications convert high-voltage power. To measure the efficiency of such conversions, it’s necessary to measure voltages of 1000 V and above. The VT1005 divides voltages of up to 5000 V and outputs them to a power analyzer. In order to measure the efficiency of high-efficiency inverters with a high degree of precision, you need to be able to accurately measure power from DC to high frequencies.

Sale Price $7174.08 CAD
Regular Price $9024.00 CAD
Availability 2 to 3 Weeks
Quantity

Hioki VT1005 Offers

Thanks to its excellent frequency flatness, the VT1005 makes possible accurate measurement at frequencies ranging from the fundamental wave to switching-frequency components.

Features

  • Divides High Voltage by 1000:1 and Outputs
  • Max. Input 5000 V (*1), 2000 V CAT II , 1500 V CAT III
  • Measurement Accuracy: ±0.08% (DC), ±0.04% (50/60 Hz), ±0.17% (50 kHz)
  • Frequency Flatness: ±0.1% Amplitude Band 200 kHz Typical
  • Frequency Flatness: ±0.1° Phase Band 500 kHz Typical (*1)
  • Measurement Band: DC to 4 MHz (-3 dB)
  • Noise Resistance: CMRR 80 dB Typical (100 kHz), Differential Input Method

The VT1005 can measure voltage with excellent accuracy across a broad band of frequencies. Accuracy is 0.1% or less at DC and commercial frequencies (50/60 Hz). In addition, the device can measure the most commonly used switching frequencies (10 kHz or less) and the switching frequencies of inverters that use SiC power devices (from 10 kHz to 50 kHz) with a high degree of accuracy.

High-voltage differential probes have a broad frequency band, but measurement error on the order of several percent occurs within that band. Thanks to high accuracy and excellent frequency flatness within its frequency band, the VT1005 makes it possible to detect efficiency improvement effects on the order of 0.1%, a task that has been impossible until now.

The VT1005 is highly resistant to both common-mode and high-frequency noise, allowing it to measure voltage accurately even in noisy environments. Since conversion devices like inverters are sources of noise, noise resistance is important in efficiency evaluation.

Hioki VT1005 Specifications

Maximum rated voltage 5000 V rms, ±7100 V peak (*1)
Maximum rated voltage (line-to-ground) No measurement category: 5000 V AC/DC (*2)
Measurement category II: 2000 V AC/DC (*3)
Measurement category III: 1500 V AC/DC (*4)
Voltage dividing ratio 1000:1
Measurement accuracy ±0.08%(DC), ±0.04%(50/60 Hz), ±0.17% (50 kHz)
Frequency flatness Band where amplitude falls within ±0.1% range: 200 kHz (typical)
Band where phase falls within ±0.1° range: 500 kHz (typical) (*5)
Measurement bandwidth DC to 4 MHz (Amplitude and phase accuracy specified up to 1 MHz)
Common-mode voltage 50 Hz/60 Hz: 90 dB(Typical)
rejection ratio (CMRR) 100 kHz: 80 dB (Typical)
Measurement method Differential input
Operating temperature and humidity range -10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing)
Storage temperature and humidity range −20°C to 60°C (-4°F to 140°F), 80% RH or less (non-condensing)
Standards Safety: EN 61010
EMC: EN 61326 Class A
Power supply 100 V to 240 V AC (50/60 Hz)
Dimensions and Weight Approx. 195.0 mm (7.68 in) W × 83.2 mm (3.28 in) H × 346.0 mm (13.62 in) D mm
Approx. 2.2 kg (77.6 oz.)

What's included with the Hioki VT1005

  • Hioki VT1005 High Voltage Divider, AC/DC

Ask a question about Hioki VT1005 High Voltage Divider, AC/DC

Customer Reviews for the Hioki VT1005

Hioki VT1005 Offers

Thanks to its excellent frequency flatness, the VT1005 makes possible accurate measurement at frequencies ranging from the fundamental wave to switching-frequency components.

Features

  • Divides High Voltage by 1000:1 and Outputs
  • Max. Input 5000 V (*1), 2000 V CAT II , 1500 V CAT III
  • Measurement Accuracy: ±0.08% (DC), ±0.04% (50/60 Hz), ±0.17% (50 kHz)
  • Frequency Flatness: ±0.1% Amplitude Band 200 kHz Typical
  • Frequency Flatness: ±0.1° Phase Band 500 kHz Typical (*1)
  • Measurement Band: DC to 4 MHz (-3 dB)
  • Noise Resistance: CMRR 80 dB Typical (100 kHz), Differential Input Method

The VT1005 can measure voltage with excellent accuracy across a broad band of frequencies. Accuracy is 0.1% or less at DC and commercial frequencies (50/60 Hz). In addition, the device can measure the most commonly used switching frequencies (10 kHz or less) and the switching frequencies of inverters that use SiC power devices (from 10 kHz to 50 kHz) with a high degree of accuracy.

High-voltage differential probes have a broad frequency band, but measurement error on the order of several percent occurs within that band. Thanks to high accuracy and excellent frequency flatness within its frequency band, the VT1005 makes it possible to detect efficiency improvement effects on the order of 0.1%, a task that has been impossible until now.

The VT1005 is highly resistant to both common-mode and high-frequency noise, allowing it to measure voltage accurately even in noisy environments. Since conversion devices like inverters are sources of noise, noise resistance is important in efficiency evaluation.

Hioki VT1005 Specifications

Maximum rated voltage 5000 V rms, ±7100 V peak (*1)
Maximum rated voltage (line-to-ground) No measurement category: 5000 V AC/DC (*2)
Measurement category II: 2000 V AC/DC (*3)
Measurement category III: 1500 V AC/DC (*4)
Voltage dividing ratio 1000:1
Measurement accuracy ±0.08%(DC), ±0.04%(50/60 Hz), ±0.17% (50 kHz)
Frequency flatness Band where amplitude falls within ±0.1% range: 200 kHz (typical)
Band where phase falls within ±0.1° range: 500 kHz (typical) (*5)
Measurement bandwidth DC to 4 MHz (Amplitude and phase accuracy specified up to 1 MHz)
Common-mode voltage 50 Hz/60 Hz: 90 dB(Typical)
rejection ratio (CMRR) 100 kHz: 80 dB (Typical)
Measurement method Differential input
Operating temperature and humidity range -10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing)
Storage temperature and humidity range −20°C to 60°C (-4°F to 140°F), 80% RH or less (non-condensing)
Standards Safety: EN 61010
EMC: EN 61326 Class A
Power supply 100 V to 240 V AC (50/60 Hz)
Dimensions and Weight Approx. 195.0 mm (7.68 in) W × 83.2 mm (3.28 in) H × 346.0 mm (13.62 in) D mm
Approx. 2.2 kg (77.6 oz.)

What's included with the Hioki VT1005

  • Hioki VT1005 High Voltage Divider, AC/DC

Ask a question about Hioki VT1005 High Voltage Divider, AC/DC

Customer Reviews for the Hioki VT1005

More Hioki Products