A space-saving, multichannel measurement module. Safely conduct charge/discharge testing of increasingly high-voltage batteries. For use with the Hioki LR8101 and LR8102 data loggers.
A space-saving, multichannel measurement module. Safely conduct charge/discharge testing of increasingly high-voltage batteries. For use with the Hioki LR8101 and LR8102 data loggers.
Features
Need a solution for use in battery cell inspections or multi-point measurement in an application like semiconductor burn-in testing? Look no further.
Assuring safety when testing cell voltages of a 1500 V battery pack: Achievement unlocked.
Although the voltage of individual cells in a battery may be low at about 4 V, safely measuring the voltage at each cell of an 400 V battery pack, a type that is already being commercialized, requires an instrument with a maximum rated terminal-to-ground voltage of at least 400 V DC.
Since the M7102 has a maximum rated terminal-to-ground voltage of 600 V, it can accommodate testing of 400 V batteries with an ample margin of safety.
Lightning-fast sampling. Fine-grained voltage fluctuation data.
Sampling rate of the M7102
The M7102 can record variations in cell voltage and temperature during charge/discharge testing of vehicle battery packs.
Furthermore, the module provides a 6 V range for lithium-ion batteries and a 2 V range for fuel cells, and measures cell voltage with a high degree of precision thanks to its 18-bit A/D resolution.
| Compatible models | Data Logger LR8101: Standard model Data Logger LR8102: Advanced model |
| Operating temperature and humidity range | −10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing) |
| Withstand voltage | 3.6 kV AC for 1 minute (sensitivity current 1 mA) Between input channels (+, −) and LR8101/LR8102, between modules 350 V AC for 1 minute (sensitivity current 1 mA) between input channels (+, −) |
| Number of input channels | 30 channels |
| Input terminal | Push-button type terminal block (2 terminals per channel), equipped with terminal block cover |
| Measurement parameters | Voltage Temperature (Thermocouple: K, J, E, T, N, R, S, B, C) |
| Input method | Scan method using semiconductor relays, floating unbalanced input All channels isolated |
| A/D resolution | 18 bits |
| Maximum input voltage | ±100 V DC |
| Maximum voltage between the channels | 300 V DC |
| Maximum rated line-to-ground voltage | 600 V AC, DC in measurement category II, anticipated transient overvoltage 4000 V |
| Maximum rated voltage between the modules | 600 V AC, DC |
| Input resistance | 100 MΩ or more ( voltage 10 mV f.s. to 6 V f.s. range, 1-5 V f.s. range, thermocouple all ranges) 1 MΩ ±5% (voltage 10 V f.s. to 100 V f.s. range) |
| Data refresh interval | 10 ms (*1), 20 ms (*2), 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s |
| Measurement range | Voltage: 10 mV f.s., 20 mV f.s., 100 mV f.s., 200 mV f.s., 1 V f.s., 2 V f.s., 6 V f.s., 10 V f.s., 20 V f.s., 60 V f.s., 100 V f.s., 1-5 V f.s. Thermocouples: 100℃ f.s., 500℃ f.s., 2000℃ f.s. |
| Dimensions and weight | Approx. 53W × 166H × 263D mm (2.1W × 6.5H × 10.4D in.), Approx. 1.2 kg (2.6 lbs) |
| Compatible models | Data Logger LR8101: Standard model Data Logger LR8102: Advanced model |
| Operating temperature and humidity range | −10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing) |
| Withstand voltage | 3.6 kV AC for 1 minute (sensitivity current 1 mA) Between input channels (+, −) and LR8101/LR8102, between modules 350 V AC for 1 minute (sensitivity current 1 mA) between input channels (+, −) |
| Number of input channels | 30 channels |
| Input terminal | Push-button type terminal block (2 terminals per channel), equipped with terminal block cover |
| Measurement parameters | Voltage Temperature (Thermocouple: K, J, E, T, N, R, S, B, C) |
| Input method | Scan method using semiconductor relays, floating unbalanced input All channels isolated |
| A/D resolution | 18 bits |
| Maximum input voltage | ±100 V DC |
| Maximum voltage between the channels | 300 V DC |
| Maximum rated line-to-ground voltage | 600 V AC, DC in measurement category II, anticipated transient overvoltage 4000 V |
| Maximum rated voltage between the modules | 600 V AC, DC |
| Input resistance | 100 MΩ or more ( voltage 10 mV f.s. to 6 V f.s. range, 1-5 V f.s. range, thermocouple all ranges) 1 MΩ ±5% (voltage 10 V f.s. to 100 V f.s. range) |
| Data refresh interval | 10 ms (*1), 20 ms (*2), 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s |
| Measurement range | Voltage: 10 mV f.s., 20 mV f.s., 100 mV f.s., 200 mV f.s., 1 V f.s., 2 V f.s., 6 V f.s., 10 V f.s., 20 V f.s., 60 V f.s., 100 V f.s., 1-5 V f.s. Thermocouples: 100℃ f.s., 500℃ f.s., 2000℃ f.s. |
| Dimensions and weight | Approx. 53W × 166H × 263D mm (2.1W × 6.5H × 10.4D in.), Approx. 1.2 kg (2.6 lbs) |