Hioki M7102 Voltage/Temperature Module

Model: M7102

Hioki M7102 Voltage/Temperature Module

Model: M7102

A space-saving, multichannel measurement module. Safely conduct charge/discharge testing of increasingly high-voltage batteries. For use with the Hioki LR8101 and LR8102 data loggers.

A space-saving, multichannel measurement module. Safely conduct charge/discharge testing of increasingly high-voltage batteries. For use with the Hioki LR8101 and LR8102 data loggers.

Sale Price $3188.75 CAD
Regular Price $4011.00 CAD
Availability 2 to 3 Weeks
Quantity

Hioki M7102 Offers

Features

  • For 600 V or lower battery packs
  • 30ch, voltage and temperature (thermocouple) measurement
  • High-precision measurement of cell voltage
  • Ideal for standalone battery cell testing and semiconductor burn-in testing
  • The M7102 cannot perform measurement by itself. A separately sold Data Logger LR8101 or LR8102 is required.

Ideal for Capturing Data from High-Voltage Battery Pack Cells

Expandability

Need a solution for use in battery cell inspections or multi-point measurement in an application like semiconductor burn-in testing? Look no further.

  • The M7102 measurement module features exceptional space efficiency and the ability to measure up to 30 channels of voltage and temperature data.
  • Up to 10 measurement modules can be connected to a single data logger, allowing the number of channels to be increased to 300 ch.
  • A JIS and EIA-standard 19-inch rack can accommodate one logger and six measurement modules for a total of 180 channels per shelf.
  • Furthermore, if up to 10 of the LR8102 advanced models are connected with optical cabling, their sampling can be synchronized, allowing the number of measurement channels to be increased to a maximum of 3000 ch.
  • It’s ideal for use in multi-point voltage and temperature measurement applications like inspections during battery cell formation processes and semiconductor burn-in testing.

Insulation

Assuring safety when testing cell voltages of a 1500 V battery pack: Achievement unlocked.

  • Terminal-to-ground voltage: 600 V DC (CAT II) Insulation
  • EN IEC 61010 Safety standard-compliant

Although the voltage of individual cells in a battery may be low at about 4 V, safely measuring the voltage at each cell of an 400 V battery pack, a type that is already being commercialized, requires an instrument with a maximum rated terminal-to-ground voltage of at least 400 V DC.

Since the M7102 has a maximum rated terminal-to-ground voltage of 600 V, it can accommodate testing of 400 V batteries with an ample margin of safety.

High Speed

Lightning-fast sampling. Fine-grained voltage fluctuation data.

Sampling rate of the M7102

  • When using 1 channel to 30 channels: Up to 20 ms
  • When using 1 channel to 15 channels: Up to 10 ms

The M7102 can record variations in cell voltage and temperature during charge/discharge testing of vehicle battery packs.

Measurement Performance

  • Measure battery cell voltage with confidence
  • Leakage current flow to the data logger can be minimized since measurement modules are engineered with a signal input resistance of 100 MΩ or greater.

Furthermore, the module provides a 6 V range for lithium-ion batteries and a 2 V range for fuel cells, and measures cell voltage with a high degree of precision thanks to its 18-bit A/D resolution.

Hioki M7102 Specifications

Compatible models Data Logger LR8101: Standard model
Data Logger LR8102: Advanced model
Operating temperature and humidity range −10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing)
Withstand voltage 3.6 kV AC for 1 minute (sensitivity current 1 mA)
Between input channels (+, −) and LR8101/LR8102, between modules 350 V AC for 1 minute (sensitivity current 1 mA) between input channels (+, −)
Number of input channels 30 channels
Input terminal Push-button type terminal block (2 terminals per channel), equipped with terminal block cover
Measurement parameters Voltage
Temperature (Thermocouple: K, J, E, T, N, R, S, B, C)
Input method Scan method using semiconductor relays, floating unbalanced input
All channels isolated
A/D resolution 18 bits
Maximum input voltage ±100 V DC
Maximum voltage between the channels 300 V DC
Maximum rated line-to-ground voltage 600 V AC, DC in measurement category II, anticipated transient overvoltage 4000 V
Maximum rated voltage between the modules 600 V AC, DC
Input resistance 100 MΩ or more ( voltage 10 mV f.s. to 6 V f.s. range, 1-5 V f.s. range, thermocouple all ranges)
1 MΩ ±5% (voltage 10 V f.s. to 100 V f.s. range)
Data refresh interval 10 ms (*1), 20 ms (*2), 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s
Measurement range Voltage: 10 mV f.s., 20 mV f.s., 100 mV f.s., 200 mV f.s., 1 V f.s., 2 V f.s., 6 V f.s., 10 V f.s., 20 V f.s., 60 V f.s., 100 V f.s., 1-5 V f.s.
Thermocouples: 100℃ f.s., 500℃ f.s., 2000℃ f.s.
Dimensions and weight Approx. 53W × 166H × 263D mm (2.1W × 6.5H × 10.4D in.), Approx. 1.2 kg (2.6 lbs)

What's included with the Hioki M7102

  • Voltage/Temperature Module
  • Instruction Manual

Ask a question about Hioki M7102 Voltage/Temperature Module

Customer Reviews for the Hioki M7102

Hioki M7102 Offers

Features

  • For 600 V or lower battery packs
  • 30ch, voltage and temperature (thermocouple) measurement
  • High-precision measurement of cell voltage
  • Ideal for standalone battery cell testing and semiconductor burn-in testing
  • The M7102 cannot perform measurement by itself. A separately sold Data Logger LR8101 or LR8102 is required.

Ideal for Capturing Data from High-Voltage Battery Pack Cells

Expandability

Need a solution for use in battery cell inspections or multi-point measurement in an application like semiconductor burn-in testing? Look no further.

  • The M7102 measurement module features exceptional space efficiency and the ability to measure up to 30 channels of voltage and temperature data.
  • Up to 10 measurement modules can be connected to a single data logger, allowing the number of channels to be increased to 300 ch.
  • A JIS and EIA-standard 19-inch rack can accommodate one logger and six measurement modules for a total of 180 channels per shelf.
  • Furthermore, if up to 10 of the LR8102 advanced models are connected with optical cabling, their sampling can be synchronized, allowing the number of measurement channels to be increased to a maximum of 3000 ch.
  • It’s ideal for use in multi-point voltage and temperature measurement applications like inspections during battery cell formation processes and semiconductor burn-in testing.

Insulation

Assuring safety when testing cell voltages of a 1500 V battery pack: Achievement unlocked.

  • Terminal-to-ground voltage: 600 V DC (CAT II) Insulation
  • EN IEC 61010 Safety standard-compliant

Although the voltage of individual cells in a battery may be low at about 4 V, safely measuring the voltage at each cell of an 400 V battery pack, a type that is already being commercialized, requires an instrument with a maximum rated terminal-to-ground voltage of at least 400 V DC.

Since the M7102 has a maximum rated terminal-to-ground voltage of 600 V, it can accommodate testing of 400 V batteries with an ample margin of safety.

High Speed

Lightning-fast sampling. Fine-grained voltage fluctuation data.

Sampling rate of the M7102

  • When using 1 channel to 30 channels: Up to 20 ms
  • When using 1 channel to 15 channels: Up to 10 ms

The M7102 can record variations in cell voltage and temperature during charge/discharge testing of vehicle battery packs.

Measurement Performance

  • Measure battery cell voltage with confidence
  • Leakage current flow to the data logger can be minimized since measurement modules are engineered with a signal input resistance of 100 MΩ or greater.

Furthermore, the module provides a 6 V range for lithium-ion batteries and a 2 V range for fuel cells, and measures cell voltage with a high degree of precision thanks to its 18-bit A/D resolution.

Hioki M7102 Specifications

Compatible models Data Logger LR8101: Standard model
Data Logger LR8102: Advanced model
Operating temperature and humidity range −10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing)
Withstand voltage 3.6 kV AC for 1 minute (sensitivity current 1 mA)
Between input channels (+, −) and LR8101/LR8102, between modules 350 V AC for 1 minute (sensitivity current 1 mA) between input channels (+, −)
Number of input channels 30 channels
Input terminal Push-button type terminal block (2 terminals per channel), equipped with terminal block cover
Measurement parameters Voltage
Temperature (Thermocouple: K, J, E, T, N, R, S, B, C)
Input method Scan method using semiconductor relays, floating unbalanced input
All channels isolated
A/D resolution 18 bits
Maximum input voltage ±100 V DC
Maximum voltage between the channels 300 V DC
Maximum rated line-to-ground voltage 600 V AC, DC in measurement category II, anticipated transient overvoltage 4000 V
Maximum rated voltage between the modules 600 V AC, DC
Input resistance 100 MΩ or more ( voltage 10 mV f.s. to 6 V f.s. range, 1-5 V f.s. range, thermocouple all ranges)
1 MΩ ±5% (voltage 10 V f.s. to 100 V f.s. range)
Data refresh interval 10 ms (*1), 20 ms (*2), 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s
Measurement range Voltage: 10 mV f.s., 20 mV f.s., 100 mV f.s., 200 mV f.s., 1 V f.s., 2 V f.s., 6 V f.s., 10 V f.s., 20 V f.s., 60 V f.s., 100 V f.s., 1-5 V f.s.
Thermocouples: 100℃ f.s., 500℃ f.s., 2000℃ f.s.
Dimensions and weight Approx. 53W × 166H × 263D mm (2.1W × 6.5H × 10.4D in.), Approx. 1.2 kg (2.6 lbs)

What's included with the Hioki M7102

  • Voltage/Temperature Module
  • Instruction Manual

Ask a question about Hioki M7102 Voltage/Temperature Module