Highly insulated module featuring high-speed sampling. Safely conduct charge/discharge testing of increasingly high-voltage batteries. For use with the Hioki LR8101 and LR8102 data loggers.
Highly insulated module featuring high-speed sampling. Safely conduct charge/discharge testing of increasingly high-voltage batteries. For use with the Hioki LR8101 and LR8102 data loggers.
Features
Evaluating high-voltage battery systems. Future-proof your system by ensuring you can accommodate more cells tomorrow.
Assuring safety when testing cell voltages of a 1500 V battery pack: Achievement unlocked.
Although the voltage of individual cells of a battery may be low at about 4 V, safely measuring the voltage at each cell of an 800 V battery pack, a type that is already being commercialized, requires an instrument with a maximum rated terminal-to-ground voltage of at least 800 V DC.
Since the M7100 has a maximum rated terminal-to-ground voltage of 1500 V, it can accommodate testing of 800 V batteries with an ample margin of safety.
It can also be used to measure cell voltage and temperature of next-generation battery packs that exceed 800 V and power storage systems such as energy storage systems (ESSs) that exceed 1000 V.
Turbocharged data transfers at an interval as short as 5 ms mean you can output data for all cells to an HIL system in real time (when using only the LR8102)
*1:UPD communication functionality is exclusive to the Data Logger LR8102.
*2:The 5 ms sampling rate is available when using 1 to 8 measurement channels. (voltage only)
Measure battery cell voltage with confidence
| Compatible models | Data Logger LR8101: Standard model Data Logger LR8102: Advanced model |
| Operating temperature and humidity range | −10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing) |
| Withstand voltage | 7.4 kV AC for 1 minute (sensitivity current 1 mA) Between input channels (+, −) and LR8101 or LR8102, between modules 350 V AC for 1 minute (sensitivity current 1 mA), between input channels (+, −) |
| Number of input channels | 15 channels |
| Input terminal | M3 screw type terminal block (2 terminals per channel), equipped with terminal block cover |
| Measurement parameters | Voltage Temperature (Thermocouple: K, J, E, T, N, R, S, B, C) |
| Input method | Scan method using semiconductor relays, floating unbalanced input |
| A/D resolution | 18 bits |
| Maximum input voltage | ±100 V DC |
| Maximum voltage between the channels | 300 V DC |
| Maximum rated line-to-ground voltage | 1500 V DC in measurement category II, anticipated transient overvoltage 8000 V 1000 V AC in measurement category II, anticipated transient overvoltage 6000 V |
| Maximum rated voltage between the modules | 1500 V DC, 1000 V AC |
| Input resistance | 100 MΩ or more (voltage 10 mV f.s. to 6 V f.s. range, 1-5 V f.s. range, thermocouple all ranges) 1 MΩ ±5% (voltage 10 V f.s. to 100 V f.s. range) |
| Data refresh interval | 5 ms (*1), 10 ms (*2), 20 ms, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s |
| Measurement range | Voltage: 10 mV f.s., 20 mV f.s., 100 mV f.s., 200 mV f.s., 1 V f.s., 2 V f.s., 6 V f.s., 10 V f.s., 20 V f.s., 60 V f.s., 100 V f.s., 1-5 V f.s. Thermocouples: 100℃ f.s., 500℃ f.s., 2000℃ f.s. |
| Dimensions and weight | Approx. 53W × 166H × 263D mm (2.1W × 6.5H × 10.4D in.), Approx. 1.3 kg (2.9 lbs) |
| Compatible models | Data Logger LR8101: Standard model Data Logger LR8102: Advanced model |
| Operating temperature and humidity range | −10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing) |
| Withstand voltage | 7.4 kV AC for 1 minute (sensitivity current 1 mA) Between input channels (+, −) and LR8101 or LR8102, between modules 350 V AC for 1 minute (sensitivity current 1 mA), between input channels (+, −) |
| Number of input channels | 15 channels |
| Input terminal | M3 screw type terminal block (2 terminals per channel), equipped with terminal block cover |
| Measurement parameters | Voltage Temperature (Thermocouple: K, J, E, T, N, R, S, B, C) |
| Input method | Scan method using semiconductor relays, floating unbalanced input |
| A/D resolution | 18 bits |
| Maximum input voltage | ±100 V DC |
| Maximum voltage between the channels | 300 V DC |
| Maximum rated line-to-ground voltage | 1500 V DC in measurement category II, anticipated transient overvoltage 8000 V 1000 V AC in measurement category II, anticipated transient overvoltage 6000 V |
| Maximum rated voltage between the modules | 1500 V DC, 1000 V AC |
| Input resistance | 100 MΩ or more (voltage 10 mV f.s. to 6 V f.s. range, 1-5 V f.s. range, thermocouple all ranges) 1 MΩ ±5% (voltage 10 V f.s. to 100 V f.s. range) |
| Data refresh interval | 5 ms (*1), 10 ms (*2), 20 ms, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s, 5 s, 10 s |
| Measurement range | Voltage: 10 mV f.s., 20 mV f.s., 100 mV f.s., 200 mV f.s., 1 V f.s., 2 V f.s., 6 V f.s., 10 V f.s., 20 V f.s., 60 V f.s., 100 V f.s., 1-5 V f.s. Thermocouples: 100℃ f.s., 500℃ f.s., 2000℃ f.s. |
| Dimensions and weight | Approx. 53W × 166H × 263D mm (2.1W × 6.5H × 10.4D in.), Approx. 1.3 kg (2.9 lbs) |