Hanna HI991301 Portable Waterproof pH/EC/TDS and Temperature Meter, High Range

Model: HI991301 | Order No: HI 991301

Hanna HI991301 Portable Waterproof pH/EC/TDS and Temperature Meter, High Range

Model: HI991301 | Order No: HI 991301

This meter is designed to measure pH, temperature, conductivity (EC) and total dissolved solids (TDS) with a single probe. All operations are performed with just two buttons. The meter is rated for IP 67 conditions and is waterproof.

This meter is designed to measure pH, temperature, conductivity (EC) and total dissolved solids (TDS) with a single probe. All operations are performed with just two buttons. The meter is rated for IP 67 conditions and is waterproof.

Sale Price $705.85 CAD
Regular Price $743.00 CAD
Availability 3 Days
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your HI 991301 Portable Waterproof pH/EC/TDS and Temperature Meter

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your HI 991301 Portable Waterproof pH/EC/TDS and Temperature Meter

Hanna HI991301 Offers

The HI1288 pre-amplified multiparameter probe features an easy-to-clean sensor and a cloth junction that can be renewed to increase the life of the probe. To ensure against interference from transient electrical noise, a solid-state amplifier is integrated into the HI1288.

Features

  • Easily fits in the palm of your hand
  • Amperometric conductivity probe
  • Built-in temperature sensor
  • The sensor is easy to clean and maintain
  • Multi parameter probe features a cloth junction that can be pulled longer, effectively increasing the life of the probe
  • Multi level LCD display
  • On-screen tutorial messages for calibration and setup
  • Automatic one or two-point- pH calibration
  • Battery % displayed on startup

Are you Making Errors when Measuring pH

  • Storing the Electrode Dry
  • Wiping the Sensing Glass
  • Storing the Electrode in DI Water
  • Not Cleaning the Electrode
  • Calibration Errors
  • Electrode Selection
  • Not Loosening or Removing the Fill Hole Cap
  • Electrolyte Selection
  • Inadequate Probe Submersion
  • Using an Old or Expired Electrode

Five Tips for Calibrating your pH Meter

  • Always Read your Manual
  • Make Sure you Have the Right pH Buffers
  • Calibrate Often
  • Be Aware of your Slope and Offset
  • Electrode Care

Hanna HI991301 Specifications

pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.01 pH
pH Calibration Automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
Conductivity Range 0.00 to 20.00 mS/cm
Conductivity Resolution 0.01 mS/cm
Conductivity Accuracy ±2% F.S.
TDS Range 0.00 to 10.00 ppt (g/L)
Click here for complete specifications on the Hanna HI991301

What's included with the Hanna HI991301

  • Portable Waterproof pH/EC/TDS Meter
  • Probe
  • Batteries
  • Rugged Carrying Case
  • Instructions

Click on a category to view a selection of compatible accessories with the Hanna HI991301 Portable Waterproof pH/EC/TDS and Temperature Meter, High Range.

Hanna Instruments HI7004L 4.01 pH Buffer Solution 1 x 500 mL bottle HI7004L
Hanna's buffer solutions are prepared according to precise formulas and are standardized with a pH meter calibrated according to the NIST standards. The 20 mL sachets are single-dose whereas, for more demanding applications, you may choose between packages of 230 mL, 500 mL, 1 Liter or 1 Gallon (3.78 L). All pH 4 solutions show batch number, expiration date and the correlation table between pH and temperature. This buffer value is widely used in water purification plants, in the food industry and where ever the pH is expected to be slightly acidic.




Hanna HI70300L Electrode Storage Solution, 500 mL HI70300L
A storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated.




Hanna HI7061L General Purpose Cleaning Solution, 500 mL HI7061L
Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. This is a general cleaning solution that can be used for a variety of applications.




Hanna HI7007L Calibration Solution, pH 7.01, 500 mL HI7007L
Calibration buffer solution with a pH of 7.01. The lot number and expiration date are clearly marked on the label, with an air tight and tamper proof seal, to ensure the quality of the solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.




Hanna HI7010L Calibration Solution, pH 10.01, 500 mL HI7010L
Calibration buffer solution with a pH of 10.01. The lot number and expiration date are clearly marked on the label, with an air tight and tamper proof seal, to ensure the quality of the solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.




Ask a question about Hanna HI991301 Portable Waterproof pH/EC/TDS and Temperature Meter, High Range

Customer Reviews for the Hanna HI991301

Hanna HI991301 Offers

The HI1288 pre-amplified multiparameter probe features an easy-to-clean sensor and a cloth junction that can be renewed to increase the life of the probe. To ensure against interference from transient electrical noise, a solid-state amplifier is integrated into the HI1288.

Features

  • Easily fits in the palm of your hand
  • Amperometric conductivity probe
  • Built-in temperature sensor
  • The sensor is easy to clean and maintain
  • Multi parameter probe features a cloth junction that can be pulled longer, effectively increasing the life of the probe
  • Multi level LCD display
  • On-screen tutorial messages for calibration and setup
  • Automatic one or two-point- pH calibration
  • Battery % displayed on startup

Are you Making Errors when Measuring pH

  • Storing the Electrode Dry
  • Wiping the Sensing Glass
  • Storing the Electrode in DI Water
  • Not Cleaning the Electrode
  • Calibration Errors
  • Electrode Selection
  • Not Loosening or Removing the Fill Hole Cap
  • Electrolyte Selection
  • Inadequate Probe Submersion
  • Using an Old or Expired Electrode

Five Tips for Calibrating your pH Meter

  • Always Read your Manual
  • Make Sure you Have the Right pH Buffers
  • Calibrate Often
  • Be Aware of your Slope and Offset
  • Electrode Care

Hanna HI991301 Specifications

pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.01 pH
pH Calibration Automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
Conductivity Range 0.00 to 20.00 mS/cm
Conductivity Resolution 0.01 mS/cm
Conductivity Accuracy ±2% F.S.
TDS Range 0.00 to 10.00 ppt (g/L)
Click here for complete specifications on the Hanna HI991301

What's included with the Hanna HI991301

  • Portable Waterproof pH/EC/TDS Meter
  • Probe
  • Batteries
  • Rugged Carrying Case
  • Instructions

Click on a category to view a selection of compatible accessories with the Hanna HI991301 Portable Waterproof pH/EC/TDS and Temperature Meter, High Range.

Hanna Instruments HI7004L 4.01 pH Buffer Solution 1 x 500 mL bottle HI7004L
Hanna's buffer solutions are prepared according to precise formulas and are standardized with a pH meter calibrated according to the NIST standards. The 20 mL sachets are single-dose whereas, for more demanding applications, you may choose between packages of 230 mL, 500 mL, 1 Liter or 1 Gallon (3.78 L). All pH 4 solutions show batch number, expiration date and the correlation table between pH and temperature. This buffer value is widely used in water purification plants, in the food industry and where ever the pH is expected to be slightly acidic.




Hanna HI70300L Electrode Storage Solution, 500 mL HI70300L
A storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated.




Hanna HI7061L General Purpose Cleaning Solution, 500 mL HI7061L
Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. This is a general cleaning solution that can be used for a variety of applications.




Hanna HI7007L Calibration Solution, pH 7.01, 500 mL HI7007L
Calibration buffer solution with a pH of 7.01. The lot number and expiration date are clearly marked on the label, with an air tight and tamper proof seal, to ensure the quality of the solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.




Hanna HI7010L Calibration Solution, pH 10.01, 500 mL HI7010L
Calibration buffer solution with a pH of 10.01. The lot number and expiration date are clearly marked on the label, with an air tight and tamper proof seal, to ensure the quality of the solution. Hanna's line of calibration buffers have been specially formulated to have an expiration of 2 years from the date of manufacture for an unopened bottle.




Ask a question about Hanna HI991301 Portable Waterproof pH/EC/TDS and Temperature Meter, High Range

Customer Reviews for the Hanna HI991301

More Hanna Products