Hanna HI7073L Cleaning Solution for Proteins, 500 mL

Model: HI7073L | Order No: HI 7073L

Hanna HI7073L Cleaning Solution for Proteins, 500 mL

Model: HI7073L | Order No: HI 7073L

Specially formulated for use in applications where a pH electrode is coated with proteins, this solution is a special enzymatic cleaning solution that eliminates impurities and residues left on the electrode surfaces. Preventing inaccuracies and clogging, the cleaning solution comes in an airtight bottle with a tamperproof seal.

Specially formulated for use in applications where a pH electrode is coated with proteins, this solution is a special enzymatic cleaning solution that eliminates impurities and residues left on the electrode surfaces. Preventing inaccuracies and clogging, the cleaning solution comes in an airtight bottle with a tamperproof seal.

Sale Price $38.95 CAD
Regular Price $41.00 CAD
Availability 2 Days
Quantity

Hanna HI7073L Offers

Ensuring maximum efficiency, the cleaning solution is specifically formulated for applications that involve the measurement of pH in a protein-based solution.

Features

  • Specially formulated cleaning solution to remove proteins from a pH electrode
  • Air tight bottle with tamper-proof seal to ensure quality
  • Expiration date and lot number clearly marked on the bottle
  • Airtight bottle with a tamper-proof seal ensures quality and freshness of solution
  • Each bottle marked with lot number and expiration date
  • Specially formulated to have an expiration of 5 years from the manufacture for an unopened bottle

Applications

  • pH measurements
  • Calibration

Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. The cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note because, during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.

The cleaning solution series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The solution is a protein cleaning solution specifically for applications that involve the measurement of pH in a protein-based solution.

What's included with the Hanna HI7073L

  • Hanna HI7073L Cleaning Solution for Proteins, 500 mL

Ask a question about Hanna HI7073L Cleaning Solution for Proteins, 500 mL

Customer Reviews for the Hanna HI7073L

Hanna HI7073L Offers

Ensuring maximum efficiency, the cleaning solution is specifically formulated for applications that involve the measurement of pH in a protein-based solution.

Features

  • Specially formulated cleaning solution to remove proteins from a pH electrode
  • Air tight bottle with tamper-proof seal to ensure quality
  • Expiration date and lot number clearly marked on the bottle
  • Airtight bottle with a tamper-proof seal ensures quality and freshness of solution
  • Each bottle marked with lot number and expiration date
  • Specially formulated to have an expiration of 5 years from the manufacture for an unopened bottle

Applications

  • pH measurements
  • Calibration

Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. The cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note because, during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.

The cleaning solution series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The solution is a protein cleaning solution specifically for applications that involve the measurement of pH in a protein-based solution.

What's included with the Hanna HI7073L

  • Hanna HI7073L Cleaning Solution for Proteins, 500 mL

Ask a question about Hanna HI7073L Cleaning Solution for Proteins, 500 mL