Digital pH electrode with a built-in temperature sensor, specifically designed for measuring the pH in wine.
Digital pH electrode with a built-in temperature sensor, specifically designed for measuring the pH in wine.
This electrode has a built-in microchip which stores sensor type, serial number and calibration information. It also features a double junction reference, Clogging Prevention System (CPS) technology, glass body and spherical tip. This probe is made to use with compatible Hanna meters with a 3.5 mm input.
Built-in Microchip
The built-in microchip stores sensor type, serial number and calibration information including date, time, offset, slope, probe condition and buffers used. This information is automatically retrieved by the edge® once the electrode is plugged in.
Spherical Glass Tip
The spherical shape tip design allows for a wide area of contact with the measured sample. This allows for a quicker electrode response with a higher degree of stability.
CPS Sleeve Junction
Conventional ph electrodes use ceramic junctions that clog quickly when used in wine. When the junction is clogged, the electrode does not function. CPS (Clogging Prevention System) is an innovative electrode technology that utilizes the porousness of ground glass coupled with a PTEE sleeve to prevent clogging of the junction.
Double Junction Reference
A double junction electrode has an internal compartment surrounding the reference wire. This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.
Glass Body Electrode
Suitable for a wide range of applications due to its chemical resistance. The glass electrode is compatible with many non-aqueous solvents and other aggressive chemicals.
Body Material | glass |
Reference | double |
Junction / Flow Rate | open, CPS technology |
Clogging Prevention System | yes |
Electrolyte | 3.5M KCl |
Range | pH: 0 to 12 |
Max Pressure | 0.1 bar |
Tip Shape | spheric |
Diameter | 12 mm |
Body Length / Overall Length | 120 mm / 175.5 mm |
Recommended Operating Temperature | 0 to 80°C (32 to 176°F) |
Temperature Sensor | yes |
Cable | coaxial; 1 m (3.3') |
Body Material | glass |
Reference | double |
Junction / Flow Rate | open, CPS technology |
Clogging Prevention System | yes |
Electrolyte | 3.5M KCl |
Range | pH: 0 to 12 |
Max Pressure | 0.1 bar |
Tip Shape | spheric |
Diameter | 12 mm |
Body Length / Overall Length | 120 mm / 175.5 mm |
Recommended Operating Temperature | 0 to 80°C (32 to 176°F) |
Temperature Sensor | yes |
Cable | coaxial; 1 m (3.3') |