GRAPHTEC GL2000 High-Speed and High Voltage TrueRMS Data Logger with 7" color display, 4-channel

Model: GL2000

GRAPHTEC GL2000 High-Speed and High Voltage TrueRMS Data Logger with 7" color display, 4-channel

Model: GL2000

This High-speed TrueRMS data logger is equipped with an isolated input mechanism to protect signals from interferences caused by noise from other channels and a 16-bit A/D converter adopted to achieve hi-speed and hi-resolution measurement. In addition, it reaches these isolated 4-channel measurements while being CAT III compatible.

This High-speed TrueRMS data logger is equipped with an isolated input mechanism to protect signals from interferences caused by noise from other channels and a 16-bit A/D converter adopted to achieve hi-speed and hi-resolution measurement. In addition, it reaches these isolated 4-channel measurements while being CAT III compatible.

Sale Price $5109.42 CAD
Regular Price $5494.00 CAD
Availability 2 to 3 Weeks
Quantity

Recommended Accessories


GRAPHTEC GL2000 Offers

Features

  • 4ch high speed simultaneous sampling
  • CAT III 600 V compatible
  • Measure AC 600 V measurements with TrueRMS
  • Built-in high-capacity RAM (4 M sampling/ch) and flash memory (4 GB)
  • Large, easy-to-read 7" LCD
  • High-speed 1 MS/s simultaneous sampling with isolated input
  • Multifunction input with CAT III measurement category: Voltage, temperature, humidity, logic, and pulse measurements can all be taken simultaneously in high speed
  • Quick and easy set-up process
  • Convenient data-recording functions
  • Equipped with Ethernet (LAN) and USB interface to communicate with PC
  • PC measurement with standard PC software included (GL980_2000-APS)
  • Advanced software GL-Connection (version 2.0)

Simultaneous Sampling - Sampling interval: 1 µs to 1 min (in steps of 1, 2, 5)

GL2000 utilizes simultaneous sampling to eliminate slowdown in sampling rate byusing multiple A/D converters in simultaneous sampling method. Four individual A/D converters in each channel sustains the maximum sampling speed for all four channels to measure high speed rapid voltage fluctuation and multi-channel vibration measurement.

External Sampling Function - Maximum input frequency: 100 kHz

Sampling of the logger is performed in sync with an external device using an external signal input. *B-513 Input/Output cable for GL is required

Pulse/Logic

  • Pulse: 4 ch (instant, accumulating RPM)
  • Logic: 4ch
  • *Select either Pulse or Logic. Required input/output cable for GL (B-513 option)

Screw Terminal (size M3.5)

  • Thermocouple: K, J, E, T, R, S, B, N (WRe5-26)
  • Humidity: 1 to 100%
  • *Required humidity sensor (B-530 option)

Applications

  • Flow rate and temperature test in water heaters
  • Thermal insulation performance measurement of residential housing
  • Performance test of inverters for air conditioner
  • Voltage and temperature measurement generators

GRAPHTEC GL2000 Specifications

Main Unit Specifications
Display (LCD) - Size 7-inch TFT color LCD (WVGA: 800 x 480 dots)
Display (LCD) - Information Waveform in Y-T with digital values, Enlarged waveforms,
Digital values and Real-time statistical result values, XY graph
Display (LCD) - Language English, French, German, Spanish, Russian, Chinese, Korean, Japanese
Interface to PC - Type Ethernet (10 BASE-T/100 BASE-TX), USB2.0
Interface to PC - Function Data transfer to PC (up to 1 ms sampling), Control command to GL2000
Interface to PC - Ethernet functions Web server function, FTP server function, NTP client function, DHCP client function, Email send function
Interface to PC - USB function USB mode (File transfer and deletion from built-in flash and SD on GL2000)
Trigger function - Trigger action Start or stop capturing data by triggering
Trigger function - Trigger source (Start) Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time
Trigger function - Trigger source (Stop) Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time
Trigger function - Combination Level OR, Level AND, Edge OR, Edge AND
Trigger function - Threshold (Analog) High or Low in level mode, Rising or Falling in edge mode, Window-in, Window-out
Trigger function - Threshold (Logic) H or L (4-channel signal pattern)
Trigger function - Threshold (Pulse) High or Rising, Low or Falling, Window-in, Window-out
Trigger function - Repeat action Off, On (Re-armed automatically)
Trigger function - Trigger hold out Hold off repeat action in specified period
Trigger function - Mode Previous start to next start, previous stop to next start
Trigger function - Defection accuracy ± 0.5 % of measurement range
Trigger function - Pre-trigger Up to the number of capturing data points (max. 4000000)
specified in built-in RAM (only when built-in RAM is used)
Alarm function - Alarm action Displays and outputs a signal when alarm is detected
Alarm function - Threshold (Analog input) High, Low, Window-in, Window-out
Alarm function - Threshold (Logic input) H or L (signal in each channel)
Alarm function - Threshold (Pulse input) High or Rising, Low or Falling, Window-in, Window-out
Alarm function - Combination OR (Source channel can be assigned with OR condition to output port)
Alarm function - Detection cycle Link with analog sampling
Alarm function - Alarm holding On or Off
Alarm function - Detection accuracy ± 0.5 % of measurement range
Storage device - Built-in RAM Four million samples for each channel
Power consumption (AC adapter in 240 V AC) Approx. 39 V A (59 V A while charging battery) with disabling screen saver
Power consumption (DC drive - 24 V) Approx. 0.5 A (0.81 A while charging battery) with disable screen saver
Power consumption (DC drive - 12 V) Approx. 1 A (Cannot charge battery) with disable screen saver
Power consumption (DC drive - 8.5 V) Approx. 1.46 A (Cannot charge battery) with disable screen saver
External dimensions [WxHxD] Approx. 260 x 161 x 83 mm (with the cover)
Weight Approx. 1.7 kg (the cover is attached, AC adapter and battery are not included)
Vibration resistance Compatible with JIS Vibration test method for automobile Type 1 Class A
(Vibration durability test: 5 m/s²)
Analog Unit Specifications
Number of input channels 4 channels
Type of input terminal Isolated BNC connector and Screw terminal (M3.5 screw) (*6)
Input method All channels isolated unbalanced input, Simultaneous sampling
Sampling speed (interval) 1 M Samples/s to 1 Sample/min (1 µs to 1 min) and External (*7)
Sampling interval 1, 2, 5, 10, 20, 50, 100, 200, 500 µs
Frequency response DC to 200 kHz (within +1/-4 dB)
Measurement range - Voltage (DC) 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000 V, and 1-5V F.S. * Max. rated safety voltage: ±600 V DC
Measurement range - DC-RMS (DC coupling and rms value meas.) 10, 25, 50, 100, 250, 500 mV rms, 1, 2, 5, 10, 25, 50, 100, 250, 500, 1000 V rms F.S. * Max. rated safety voltage: 600 V rms
Measurement range - Temperature Thermocouple: K, J, E, T, R, S, B, N, W (WRe5-26)
Measurement range - Humidity 0 to 100 % RH - using the humidity sensor (option B-530)
Filter (Low pass) Off, Line (1.5 Hz), 5, 50, 500 Hz, 50 kHz (at -3dB, -6dB/oct)
A/D converter 16-bit (effective resolution: 1/40000 of the measuring full range)
Measurement accuracy - Voltage (DC) ± 0.25% of Full Scale
Measurement accuracy - Voltage (RMS) ± 1.5% of Full Scale (Sine wave in 20 Hz - 10 kHz)
Measurement accuracy - Temperature (Thermocouple) Type: R/S, B, K, E, T, J, N, W
R.J. Compensation Internal or External
Burnout Detecting burnout of Thermocouple with menu operation in free-run mode
Input impedance 1 M&Ohm; ±5%
Signal source impedance up to 1 k&Ohm;
Maximum input voltage Between(+) - (-) terminals: 20 mV to 2 V range: 30 V DC/AC, 5 V to 1000 V range: 600 V DC/AC
Between channels (-) - (-) terminals: 600 V DC/AC (CAT III)
Between channel - GND: 600 V DC/AC (CAT III)
Isolation Resistance Min. 500 M&Ohm; (at 500 V DC) with between input and GND
Common-mode rejection ratio Min. 90 dB (50/60 Hz, signal source impedance: max. 300 &Ohm;)
Signal-Noise Ratio (S/N) 20 mV range: -40 dB (when input terminals + and - are shorted)
Other range: -50 dB (when input terminals + and - are shorted)
Click here for complete specifications on the GRAPHTEC GL2000

What's included with the GRAPHTEC GL2000

  • GRAPHTEC GL2000 High-Speed and High Voltage TrueRMS Data Logger with 7" color display, 4-channel

Click on a category to view a selection of compatible accessories with the GRAPHTEC GL2000 High-Speed and High Voltage TrueRMS Data Logger with 7" color display, 4-channel.

GRAPHTEC B-579 Rubber Protector for the GL2000/980 series B-579
Rubber protector for the GL2000/980 series.




Ask a question about GRAPHTEC GL2000 High-Speed and High Voltage TrueRMS Data Logger with 7" color display, 4-channel

Customer Reviews for the GRAPHTEC GL2000

GRAPHTEC GL2000 Offers

Features

  • 4ch high speed simultaneous sampling
  • CAT III 600 V compatible
  • Measure AC 600 V measurements with TrueRMS
  • Built-in high-capacity RAM (4 M sampling/ch) and flash memory (4 GB)
  • Large, easy-to-read 7" LCD
  • High-speed 1 MS/s simultaneous sampling with isolated input
  • Multifunction input with CAT III measurement category: Voltage, temperature, humidity, logic, and pulse measurements can all be taken simultaneously in high speed
  • Quick and easy set-up process
  • Convenient data-recording functions
  • Equipped with Ethernet (LAN) and USB interface to communicate with PC
  • PC measurement with standard PC software included (GL980_2000-APS)
  • Advanced software GL-Connection (version 2.0)

Simultaneous Sampling - Sampling interval: 1 µs to 1 min (in steps of 1, 2, 5)

GL2000 utilizes simultaneous sampling to eliminate slowdown in sampling rate byusing multiple A/D converters in simultaneous sampling method. Four individual A/D converters in each channel sustains the maximum sampling speed for all four channels to measure high speed rapid voltage fluctuation and multi-channel vibration measurement.

External Sampling Function - Maximum input frequency: 100 kHz

Sampling of the logger is performed in sync with an external device using an external signal input. *B-513 Input/Output cable for GL is required

Pulse/Logic

  • Pulse: 4 ch (instant, accumulating RPM)
  • Logic: 4ch
  • *Select either Pulse or Logic. Required input/output cable for GL (B-513 option)

Screw Terminal (size M3.5)

  • Thermocouple: K, J, E, T, R, S, B, N (WRe5-26)
  • Humidity: 1 to 100%
  • *Required humidity sensor (B-530 option)

Applications

  • Flow rate and temperature test in water heaters
  • Thermal insulation performance measurement of residential housing
  • Performance test of inverters for air conditioner
  • Voltage and temperature measurement generators

GRAPHTEC GL2000 Specifications

Main Unit Specifications
Display (LCD) - Size 7-inch TFT color LCD (WVGA: 800 x 480 dots)
Display (LCD) - Information Waveform in Y-T with digital values, Enlarged waveforms,
Digital values and Real-time statistical result values, XY graph
Display (LCD) - Language English, French, German, Spanish, Russian, Chinese, Korean, Japanese
Interface to PC - Type Ethernet (10 BASE-T/100 BASE-TX), USB2.0
Interface to PC - Function Data transfer to PC (up to 1 ms sampling), Control command to GL2000
Interface to PC - Ethernet functions Web server function, FTP server function, NTP client function, DHCP client function, Email send function
Interface to PC - USB function USB mode (File transfer and deletion from built-in flash and SD on GL2000)
Trigger function - Trigger action Start or stop capturing data by triggering
Trigger function - Trigger source (Start) Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time
Trigger function - Trigger source (Stop) Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time
Trigger function - Combination Level OR, Level AND, Edge OR, Edge AND
Trigger function - Threshold (Analog) High or Low in level mode, Rising or Falling in edge mode, Window-in, Window-out
Trigger function - Threshold (Logic) H or L (4-channel signal pattern)
Trigger function - Threshold (Pulse) High or Rising, Low or Falling, Window-in, Window-out
Trigger function - Repeat action Off, On (Re-armed automatically)
Trigger function - Trigger hold out Hold off repeat action in specified period
Trigger function - Mode Previous start to next start, previous stop to next start
Trigger function - Defection accuracy ± 0.5 % of measurement range
Trigger function - Pre-trigger Up to the number of capturing data points (max. 4000000)
specified in built-in RAM (only when built-in RAM is used)
Alarm function - Alarm action Displays and outputs a signal when alarm is detected
Alarm function - Threshold (Analog input) High, Low, Window-in, Window-out
Alarm function - Threshold (Logic input) H or L (signal in each channel)
Alarm function - Threshold (Pulse input) High or Rising, Low or Falling, Window-in, Window-out
Alarm function - Combination OR (Source channel can be assigned with OR condition to output port)
Alarm function - Detection cycle Link with analog sampling
Alarm function - Alarm holding On or Off
Alarm function - Detection accuracy ± 0.5 % of measurement range
Storage device - Built-in RAM Four million samples for each channel
Power consumption (AC adapter in 240 V AC) Approx. 39 V A (59 V A while charging battery) with disabling screen saver
Power consumption (DC drive - 24 V) Approx. 0.5 A (0.81 A while charging battery) with disable screen saver
Power consumption (DC drive - 12 V) Approx. 1 A (Cannot charge battery) with disable screen saver
Power consumption (DC drive - 8.5 V) Approx. 1.46 A (Cannot charge battery) with disable screen saver
External dimensions [WxHxD] Approx. 260 x 161 x 83 mm (with the cover)
Weight Approx. 1.7 kg (the cover is attached, AC adapter and battery are not included)
Vibration resistance Compatible with JIS Vibration test method for automobile Type 1 Class A
(Vibration durability test: 5 m/s²)
Analog Unit Specifications
Number of input channels 4 channels
Type of input terminal Isolated BNC connector and Screw terminal (M3.5 screw) (*6)
Input method All channels isolated unbalanced input, Simultaneous sampling
Sampling speed (interval) 1 M Samples/s to 1 Sample/min (1 µs to 1 min) and External (*7)
Sampling interval 1, 2, 5, 10, 20, 50, 100, 200, 500 µs
Frequency response DC to 200 kHz (within +1/-4 dB)
Measurement range - Voltage (DC) 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000 V, and 1-5V F.S. * Max. rated safety voltage: ±600 V DC
Measurement range - DC-RMS (DC coupling and rms value meas.) 10, 25, 50, 100, 250, 500 mV rms, 1, 2, 5, 10, 25, 50, 100, 250, 500, 1000 V rms F.S. * Max. rated safety voltage: 600 V rms
Measurement range - Temperature Thermocouple: K, J, E, T, R, S, B, N, W (WRe5-26)
Measurement range - Humidity 0 to 100 % RH - using the humidity sensor (option B-530)
Filter (Low pass) Off, Line (1.5 Hz), 5, 50, 500 Hz, 50 kHz (at -3dB, -6dB/oct)
A/D converter 16-bit (effective resolution: 1/40000 of the measuring full range)
Measurement accuracy - Voltage (DC) ± 0.25% of Full Scale
Measurement accuracy - Voltage (RMS) ± 1.5% of Full Scale (Sine wave in 20 Hz - 10 kHz)
Measurement accuracy - Temperature (Thermocouple) Type: R/S, B, K, E, T, J, N, W
R.J. Compensation Internal or External
Burnout Detecting burnout of Thermocouple with menu operation in free-run mode
Input impedance 1 M&Ohm; ±5%
Signal source impedance up to 1 k&Ohm;
Maximum input voltage Between(+) - (-) terminals: 20 mV to 2 V range: 30 V DC/AC, 5 V to 1000 V range: 600 V DC/AC
Between channels (-) - (-) terminals: 600 V DC/AC (CAT III)
Between channel - GND: 600 V DC/AC (CAT III)
Isolation Resistance Min. 500 M&Ohm; (at 500 V DC) with between input and GND
Common-mode rejection ratio Min. 90 dB (50/60 Hz, signal source impedance: max. 300 &Ohm;)
Signal-Noise Ratio (S/N) 20 mV range: -40 dB (when input terminals + and - are shorted)
Other range: -50 dB (when input terminals + and - are shorted)
Click here for complete specifications on the GRAPHTEC GL2000

What's included with the GRAPHTEC GL2000

  • GRAPHTEC GL2000 High-Speed and High Voltage TrueRMS Data Logger with 7" color display, 4-channel

Click on a category to view a selection of compatible accessories with the GRAPHTEC GL2000 High-Speed and High Voltage TrueRMS Data Logger with 7" color display, 4-channel.

GRAPHTEC B-579 Rubber Protector for the GL2000/980 series B-579
Rubber protector for the GL2000/980 series.




Ask a question about GRAPHTEC GL2000 High-Speed and High Voltage TrueRMS Data Logger with 7" color display, 4-channel

Customer Reviews for the GRAPHTEC GL2000

More GRAPHTEC Products