Suitable for high-performance applications, this folding analog multimeter works with 46 measuring ranges of up to 600 V for direct and alternating voltages. Work with outstanding protection with this rugged multimeter that can handle mechanical stress and works in RMS values.
Suitable for high-performance applications, this folding analog multimeter works with 46 measuring ranges of up to 600 V for direct and alternating voltages. Work with outstanding protection with this rugged multimeter that can handle mechanical stress and works in RMS values.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
Features
Applications
| Measuring Ranges | Voltage: 100 mV, 300 mV, 1 V, 3 V, 10 V, 30 V, 100 V, 300 V and 600 V Alternating voltage levels: -40 to 62 dB Current: 10 µA, 100 µA, 1mA, 10 mA, 100 mA, 1 A and 10 A Resistance: 1 Ω to 2 kΩ, 10 Ω to 20 kΩ, 100 Ω to 200 kΩ, 1 kΩ to 2 MΩ, 10 kΩ to 20 MΩ |
| Overload Protection | 600 V≂ |
| Postition | Normal use: Instrument and scale horizontal ±1° Additional influence error of maximum ±1% of the scale length if the scale is tilted between 0 and ±120° relative to horizontal |
| Frequency | Additional influence error of maximum ±5% of full scale value in the following ranges: 100 mV, 3 to 600 V: 15 Hz to 1 kHz 10 μA to 10 A: 15 Hz to 1 kHz 300 mV, 1 V: 15 to 200 Hz |
| Auxiliary voltage | No additional influence error. The upper limit must be set with the potentiometer for all measuring ranges in the case of resistance measurement |
| Temperature | 41 to 73.4 to 95°F (5 to 23 to 35°C) Ambient: 73.4°F (23°C) ±2 K Limits: Accuracy: 41 to 95°F (5 to 35°C) Operation: 32 to 104°F (0 to 40°C) Storage: -13 to 149°F (-25 to 65°C), without batteries |
| Relative Humidity | 40 to 60% |
| Measured Quantity | Frequency: 45 to 65 Hz Waveshape: Sine |
| Fuses | Ranges to 1 A and Ω: FF 1.6 A / 600 V, 0.23 x 1.26" (6 x 32 mm) in combination with rectifier diodes for the 10 μA to 1 A and Ω x1 to kΩ x10 ranges, switching capacity: 50 kA at 600 V~ 10 A range: FF 16 A / 600 V AC, 0.23 x 1.26" (6 x 32 mm), switching capacity: 50 kA at 600 V~ |
| Common Mode Interference Voltage Damping | >120 dB, DC and 50 Hz AC |
| Interference | Emission: EN 61326:2006 class B Immunity: EN 61326-1: 2006 and EN 61326-2-1: 2006 |
| Battery | Voltage: 7.5 V ±0.1 V Operation: Nominal voltage: 9 V- , 9 V flat cell battery per IEC 6LR61 (6F22), alkaline manganese or NiMH rechargeable battery Service life: With alkaline manganese: approximately 1000 hours, with NiCd: approximately 200 hours, in the Ω x 1 range: ¼ of specified service life Test: Pointer must be within the battery test field |
| Protection | Housing: IP 40 Connector jacks: IP 20 |
| Dimensions | 5.7 x 4.6 x 1.7" (146 x 118 x 44 mm), folded closed |
| Weight | Approximately 0.99 lbs (45 kg) |
Click on a category to view a selection of compatible accessories with the Gossen Metrawatt M113A METRAport 3A Folding Analog Multimeter for High Performance Applications.
| Measuring Ranges | Voltage: 100 mV, 300 mV, 1 V, 3 V, 10 V, 30 V, 100 V, 300 V and 600 V Alternating voltage levels: -40 to 62 dB Current: 10 µA, 100 µA, 1mA, 10 mA, 100 mA, 1 A and 10 A Resistance: 1 Ω to 2 kΩ, 10 Ω to 20 kΩ, 100 Ω to 200 kΩ, 1 kΩ to 2 MΩ, 10 kΩ to 20 MΩ |
| Overload Protection | 600 V≂ |
| Postition | Normal use: Instrument and scale horizontal ±1° Additional influence error of maximum ±1% of the scale length if the scale is tilted between 0 and ±120° relative to horizontal |
| Frequency | Additional influence error of maximum ±5% of full scale value in the following ranges: 100 mV, 3 to 600 V: 15 Hz to 1 kHz 10 μA to 10 A: 15 Hz to 1 kHz 300 mV, 1 V: 15 to 200 Hz |
| Auxiliary voltage | No additional influence error. The upper limit must be set with the potentiometer for all measuring ranges in the case of resistance measurement |
| Temperature | 41 to 73.4 to 95°F (5 to 23 to 35°C) Ambient: 73.4°F (23°C) ±2 K Limits: Accuracy: 41 to 95°F (5 to 35°C) Operation: 32 to 104°F (0 to 40°C) Storage: -13 to 149°F (-25 to 65°C), without batteries |
| Relative Humidity | 40 to 60% |
| Measured Quantity | Frequency: 45 to 65 Hz Waveshape: Sine |
| Fuses | Ranges to 1 A and Ω: FF 1.6 A / 600 V, 0.23 x 1.26" (6 x 32 mm) in combination with rectifier diodes for the 10 μA to 1 A and Ω x1 to kΩ x10 ranges, switching capacity: 50 kA at 600 V~ 10 A range: FF 16 A / 600 V AC, 0.23 x 1.26" (6 x 32 mm), switching capacity: 50 kA at 600 V~ |
| Common Mode Interference Voltage Damping | >120 dB, DC and 50 Hz AC |
| Interference | Emission: EN 61326:2006 class B Immunity: EN 61326-1: 2006 and EN 61326-2-1: 2006 |
| Battery | Voltage: 7.5 V ±0.1 V Operation: Nominal voltage: 9 V- , 9 V flat cell battery per IEC 6LR61 (6F22), alkaline manganese or NiMH rechargeable battery Service life: With alkaline manganese: approximately 1000 hours, with NiCd: approximately 200 hours, in the Ω x 1 range: ¼ of specified service life Test: Pointer must be within the battery test field |
| Protection | Housing: IP 40 Connector jacks: IP 20 |
| Dimensions | 5.7 x 4.6 x 1.7" (146 x 118 x 44 mm), folded closed |
| Weight | Approximately 0.99 lbs (45 kg) |
Click on a category to view a selection of compatible accessories with the Gossen Metrawatt M113A METRAport 3A Folding Analog Multimeter for High Performance Applications.