FD08 Digital Formaldehyde Meter Handheld is a digital meter that uses an electromechanical sensor to measure real-time formaldehyde gas concentrations to ensure compliance with safety standards and to maintain indoor air quality. It features easy one-button calibration in the fresh air, adjustable alarm for higher concentrations, RH measurements, and is CE and RoHS approved.
FD08 Digital Formaldehyde Meter Handheld is a digital meter that uses an electromechanical sensor to measure real-time formaldehyde gas concentrations to ensure compliance with safety standards and to maintain indoor air quality. It features easy one-button calibration in the fresh air, adjustable alarm for higher concentrations, RH measurements, and is CE and RoHS approved.
The FD08 is ideal for measuring levels of gaseous formaldehyde (HCHO) as part of a workplace indoor air quality (IAQ) maintenance program. It can also spot-check a residential environment.
Features
Applications
Formaldehyde Range/ Resolution |
0 to 5 ppm / 0.01 ppm |
Formaldehyde Accuracy | ±(5% + 0.03 ppm) |
Formaldehyde Sensor Type/Warmup Time |
Electrochemical 1 to 15 minutes, typical |
Temperature Range | 0 to 122°F (0 to 50°C) |
Temperature Accuracy/ Resolution |
±1.8°F (1°C) / 0.1° |
RH Range | 10 to 90% RH |
RH Accuracy /Resolution | ±5% of reading |
Display Type / Size | Dual readout LCD / 2" (51 mm) diagonal |
Auto Power Off Trigger | 15 minutes of frontpanel inactivity (can be disabled) |
Operating Temperature | 32 to 122°F (0 to 50°C) at 0 to 95% RH, non-condensing |
Dimensions | 8.3 x 2.4 x 1.0" (210 x 60 x 25 mm) |
Weight | 7.2 oz. (204 g), including batteries |
Power Source | Four AAA batteries (not included) or optional 110V AC adapter (General P/N AC2) |
Formaldehyde Range/ Resolution |
0 to 5 ppm / 0.01 ppm |
Formaldehyde Accuracy | ±(5% + 0.03 ppm) |
Formaldehyde Sensor Type/Warmup Time |
Electrochemical 1 to 15 minutes, typical |
Temperature Range | 0 to 122°F (0 to 50°C) |
Temperature Accuracy/ Resolution |
±1.8°F (1°C) / 0.1° |
RH Range | 10 to 90% RH |
RH Accuracy /Resolution | ±5% of reading |
Display Type / Size | Dual readout LCD / 2" (51 mm) diagonal |
Auto Power Off Trigger | 15 minutes of frontpanel inactivity (can be disabled) |
Operating Temperature | 32 to 122°F (0 to 50°C) at 0 to 95% RH, non-condensing |
Dimensions | 8.3 x 2.4 x 1.0" (210 x 60 x 25 mm) |
Weight | 7.2 oz. (204 g), including batteries |
Power Source | Four AAA batteries (not included) or optional 110V AC adapter (General P/N AC2) |