Compatible with all GCT multi-gas and single-gas diffusion detectors, this motorized external pump allows air sampling from up to 75' (23 m) away. It features single-button operation and easily attaches to compatible detectors. Ideal for safety professionals requiring remote gas monitoring, its durable casing withstands harsh environments.
Compatible with all GCT multi-gas and single-gas diffusion detectors, this motorized external pump allows air sampling from up to 75' (23 m) away. It features single-button operation and easily attaches to compatible detectors. Ideal for safety professionals requiring remote gas monitoring, its durable casing withstands harsh environments.
Features
| Temperature Range | -7.6 to 122°F (-22 to 50°C) |
| Humidity | 5 to 100% RH (non‑condensing) |
| Battery Life | 40 continuous hours (typical) |
| Charge Time | 4 to 6 hours (typical) |
| Alarms | Visual & audible (minimum 95 dB) |
| Pump Flow LED | Indicates pump is on and/or blocked |
| Power LED | Indicates pump is on and shows battery level |
| Battery LED | Indicates charging status and full charge |
| Self‑Test | Full‑function test on activation |
| Battery Test | Runs continuously |
| Rating | IP68 |
| Gas Inlet | 1/8" (3.17 mm) stainless steel barbed fitting |
| Pump Draw | Up to 75' (23 m) |
| Sample Delay Time | Less than 1 second per 1' (0.3 m) with 1/8" (32 mm) ID tubing |
| CSA Certification | C22.2 No. 152; CSA21CA80033769X; ANSI/ISA S12.13.01; Intrinsically Safe; Class I Div 1 Groups A–D T4; Class I Zone 0 AEx ia IIC T4 Ga; -20°C ≤ Ta ≤ +50°C; 4.2 Vdc |
| IECEx Certification | IECEx CSA 21.0006X; Ex ia IIC T4 Ga; IEC 60079‑0:2017; IEC 60079‑11:2011; -20°C ≤ Ta ≤ +50°C; 4.2 Vdc |
| ATEX Certification | CSANe ATEX1243X; CE 2813 II 1 G Ex ia IIC T4 Ga; EN 60079‑0:2018; EN 60079‑11:2012; -20°C ≤ Ta ≤ +50°C; 4.2 Vdc |
| Dimensions | 6.4 × 2.6 × 1.25" (163 × 68 × 31 mm) |
| Weight | 8 oz (235 g) |
Click on a category to view a selection of compatible accessories with the Gas Clip GCT-XP External Pump for the GCT gas detectors.
| Temperature Range | -7.6 to 122°F (-22 to 50°C) |
| Humidity | 5 to 100% RH (non‑condensing) |
| Battery Life | 40 continuous hours (typical) |
| Charge Time | 4 to 6 hours (typical) |
| Alarms | Visual & audible (minimum 95 dB) |
| Pump Flow LED | Indicates pump is on and/or blocked |
| Power LED | Indicates pump is on and shows battery level |
| Battery LED | Indicates charging status and full charge |
| Self‑Test | Full‑function test on activation |
| Battery Test | Runs continuously |
| Rating | IP68 |
| Gas Inlet | 1/8" (3.17 mm) stainless steel barbed fitting |
| Pump Draw | Up to 75' (23 m) |
| Sample Delay Time | Less than 1 second per 1' (0.3 m) with 1/8" (32 mm) ID tubing |
| CSA Certification | C22.2 No. 152; CSA21CA80033769X; ANSI/ISA S12.13.01; Intrinsically Safe; Class I Div 1 Groups A–D T4; Class I Zone 0 AEx ia IIC T4 Ga; -20°C ≤ Ta ≤ +50°C; 4.2 Vdc |
| IECEx Certification | IECEx CSA 21.0006X; Ex ia IIC T4 Ga; IEC 60079‑0:2017; IEC 60079‑11:2011; -20°C ≤ Ta ≤ +50°C; 4.2 Vdc |
| ATEX Certification | CSANe ATEX1243X; CE 2813 II 1 G Ex ia IIC T4 Ga; EN 60079‑0:2018; EN 60079‑11:2012; -20°C ≤ Ta ≤ +50°C; 4.2 Vdc |
| Dimensions | 6.4 × 2.6 × 1.25" (163 × 68 × 31 mm) |
| Weight | 8 oz (235 g) |