We Ship Free on Orders Over $99 within Canada
Yopto star rating

Customer Rating: 4.7/5 Stars

Keeping Your World Up & Running®

FREE STUFF! VALUE ADDED KITS!

FREE SHIPPING ON ONLINE ORDERS OVER $99*

Fluke 116/62 MAX+ HVAC Multimeter and IR Thermometer Kit

Model: 116/62-MAX+ | Order No: 116/62MAX+

Fluke 116/62 MAX+ HVAC Multimeter and IR Thermometer Kit

Model: 116/62-MAX+ | Order No: 116/62MAX+

This combo kit includes the Fluke 116 HVAC multimeter, 62MAX+ IR thermometer, 80PK-1 thermocouple, 80AK adapter, 80BK probe, TL75 test leads, C115 case, and TPAK meter hanger.

This combo kit includes the Fluke 116 HVAC multimeter, 62MAX+ IR thermometer, 80PK-1 thermocouple, 80AK adapter, 80BK probe, TL75 test leads, C115 case, and TPAK meter hanger.

Sale Price $307.80 CAD
Regular Price $342.00 CAD
Availability 2 in Stock
Quantity

Add In-House ISO Certified Calibration to your 62 MAX+

Add In-House ISO Certified Calibration to your 116

Add In-House ISO Certified Calibration to your 62 MAX+

Add In-House ISO Certified Calibration to your 116


Recommended Accessories


Fluke 116/62MAX+ Offers

FLUKE 116 HVAC Multimeter with Temperature and Microamps

  • Built-in thermometer for HVAC applications
  • Microamps to test flame sensors
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas

FLUKE 62MAX+ Infrared Thermometer

  • Temperature range: -30 °C to 650 °C (-22 °F to 1202 °F)
  • Bright laser beam provides easy targeting
  • Display clearly supplies data at a glance
  • Shock-absorbing holster increases ruggedness<

FLUKE TL75 Hard Point Test Lead Set

  • One pair (red, black) of comfort grip probes
  • 48 inches (1.22 meter) PVC insulated test leads with right-angle shrouded banana plugs
  • Recommended for general purpose measurements
  • CAT IV 600 V, CAT III 1000 V, 10 A rating. CSA listed.

FLUKE 80BK Integrated Temperature Probe

  • Type-K thermocouple with standard shrouded banana jack
  • Convenient one piece construction
  • Compatible with DMMs with temperature measurement functions
  • Measurement range:-40 to 260°C

FLUKE 80AK Thermocouple Adapter

  • Adapts Type-K thermocouple mini-connector to dual shrouded banana plug inputs
  • Measurement range and accuracy: probe dependent
  • Suitable for low voltage applications(below 30 V AC, 60 V DC)

FLUKE 80PK-11 Pipe Wrap Thermocouple

  • Designed for hands free measurement of HVAC temperature measuring applications
  • Use multiple and leave in place for route based routine maintenance
  • Use with any temperature-measuring instrument designed to accept Type-K thermocouples

Fluke 116 Specifications

Specifications
Maximum voltage between any terminal and earth ground

600 V
Surge protection

6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital6,000 counts, updates 4 per second
Bar graph

33 segments, updates 32 per second
Operating Temperature

-10 °C to + 50 °C
Storage Temperature

-40 °C to + 60 °C
Battery type

9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life

400 hours typical, without backlight

Accuracy Specifications
DC millivolts
Range600.0 mV
Resolution0.1 mV
Accuracy± ([% of reading] + [counts]): 2.0% + 3
DC volts
Range/Resolution6.000 V / 0.001 V
Range/Resolution60.00 V / 0.01 V
Range/Resolution600.00 V / 0.1 V
Auto volts
Range600.0 V
Resolution0.1 V
Accuracy2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range600.0 mV
Resolution0.1 mV
Accuracy1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution6.000 V / 0.001 V
Range/Resolution60.00 V / 0.01 V
Range/Resolution600.0 V / 0.1 V
Accuracy1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range600 Ω
Resolution1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution600.0 Ω / 0.1 Ω
Range/Resolution6.000 kΩ / 0.001 kΩ
Range/Resolution60.00 kΩ / 0.01 kΩ
Range/Resolution600.0 kΩ / 0.1 kΩ
Range/Resolution6.000 MΩ / 0.001 MΩ
Accuracy0.9 % + 1
Range/Resolution40.00 MΩ / 0.01 MΩ
Accuracy1.5 % + 2
Diode Test
Range/Resolution2.000 V / 0.001 V
Accuracy0.9% + 2
Capacitance
Range/Resolution1000 nF / 1 nF
Range/Resolution10.00 μF / 0.01 μF
Range/Resolution100.0 μF / 0.1 μF
Range/Resolution9999 μF / 1 μF
Range/Resolution100 μF to 1000 μF
Accuracy1.9% + 2
Range/Resolution> 1000 μF
Accuracy5% + 20%
LoZ capacitance
Range1 nF to 500 μF
Accuracy10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution-40 °C to 400 °C / 0.1 °C
Accuracy1% + 102
Range/Resolution-40 °F to 752 °C / 0.2 °F
Accuracy1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution600.0 μA / 0.1 μA
Accuracy1.0% + 2
DC μamps
Range/Resolution600.0 μA / 0.1 μA
Accuracy1.0% + 2
Hz (V or A input)2
Range/Resolution99.99 Hz / 0.01 Hz
Range/Resolution999.99 Hz / 0.1 Hz
Range/Resolution9.999 Hz / 0.001 Hz
Range/Resolution50.00 Hz / 0.01 Hz
Accuracy0.1% + 2

Notes:
1) All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.

Mechanical & General Specifications
Size
Height27.62 cm (10.875")
Length15.875 cm (6.25")
Width5.6 cm (2.203")
Weight

607 g (1.34 lbs)
Warranty

3 years


Fluke 62 MAX+ Specifications

Specifications

Temperature Range

Fluke 62 MAX -30 °C to 500 °C (-22 °F to 932 °F)
Fluke 62+ MAX -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
Fluke 62 MAX ±1.5 °C or ±1.5% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Fluke 62+ MAX ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX <500 ms (95% of reading)
Fluke 62+ MAX <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

Fluke 62 MAX 10:1 (calculated at 90% energy)
Fluke 62+ MAX 12:1 (calculated at 90% energy)
Display Resolution
0.1 °C (0.2 °F)
Repeatability of Readings
Fluke 62 MAX ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater
Fluke 62+ MAX ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
AA battery
Battery Life
Fluke 62 MAX 10 hours with laser and backlight on
Fluke 62+ MAX 8 hours with laser and backlight on

Physical Specifications

Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II
Click here for complete specifications on the Fluke 116/62-MAX+

What's included with the Fluke 116/62-MAX+

  • Fluke 116 HVAC Multimeter with Temperature and Microamps.
  • TL75 Hard Point Test Lead Set.
  • TPak ToolPak Magnetic Meter Hanging Strap.
  • Flexible Cuff Pipe Clamp Thermocouple.
  • 80BK Integrated Temperature Probe.
  • 80AK-A Thermocouple Adapter.
  • C115 Deluxe Soft Carrying Case with Shoulder Strap.
  • Fluke 62 MAX+ Infrared Thermometer

Click on a category to view a selection of compatible accessories with the Fluke 116/62 MAX+ HVAC Multimeter and IR Thermometer Combo Kit.

-
Fluke TL225 SureGrip Stray Voltage Adapter Test Lead Kit TL225
Voltage Adapter Test Lead Kit makes sure the meter has a low input impedance that eliminates stray voltages and indicates real voltage.




Review the Fluke Corporation 116/62-MAX+

" data-description="The complete solution to HVAC troubleshooting. The kit includes Fluke 116 Digital Multimeter, Fluke 62 MAX+ Infrared Thermometer, and a range of accessories.">

Ask a question about Fluke 116/62 MAX+ HVAC Multimeter and IR Thermometer Combo Kit

Fluke 116/62MAX+ Offers

FLUKE 116 HVAC Multimeter with Temperature and Microamps

  • Built-in thermometer for HVAC applications
  • Microamps to test flame sensors
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas

FLUKE 62MAX+ Infrared Thermometer

  • Temperature range: -30 °C to 650 °C (-22 °F to 1202 °F)
  • Bright laser beam provides easy targeting
  • Display clearly supplies data at a glance
  • Shock-absorbing holster increases ruggedness<

FLUKE TL75 Hard Point Test Lead Set

  • One pair (red, black) of comfort grip probes
  • 48 inches (1.22 meter) PVC insulated test leads with right-angle shrouded banana plugs
  • Recommended for general purpose measurements
  • CAT IV 600 V, CAT III 1000 V, 10 A rating. CSA listed.

FLUKE 80BK Integrated Temperature Probe

  • Type-K thermocouple with standard shrouded banana jack
  • Convenient one piece construction
  • Compatible with DMMs with temperature measurement functions
  • Measurement range:-40 to 260°C

FLUKE 80AK Thermocouple Adapter

  • Adapts Type-K thermocouple mini-connector to dual shrouded banana plug inputs
  • Measurement range and accuracy: probe dependent
  • Suitable for low voltage applications(below 30 V AC, 60 V DC)

FLUKE 80PK-11 Pipe Wrap Thermocouple

  • Designed for hands free measurement of HVAC temperature measuring applications
  • Use multiple and leave in place for route based routine maintenance
  • Use with any temperature-measuring instrument designed to accept Type-K thermocouples

Fluke 116 Specifications

Specifications
Maximum voltage between any terminal and earth ground

600 V
Surge protection

6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital6,000 counts, updates 4 per second
Bar graph

33 segments, updates 32 per second
Operating Temperature

-10 °C to + 50 °C
Storage Temperature

-40 °C to + 60 °C
Battery type

9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life

400 hours typical, without backlight

Accuracy Specifications
DC millivolts
Range600.0 mV
Resolution0.1 mV
Accuracy± ([% of reading] + [counts]): 2.0% + 3
DC volts
Range/Resolution6.000 V / 0.001 V
Range/Resolution60.00 V / 0.01 V
Range/Resolution600.00 V / 0.1 V
Auto volts
Range600.0 V
Resolution0.1 V
Accuracy2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range600.0 mV
Resolution0.1 mV
Accuracy1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution6.000 V / 0.001 V
Range/Resolution60.00 V / 0.01 V
Range/Resolution600.0 V / 0.1 V
Accuracy1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range600 Ω
Resolution1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution600.0 Ω / 0.1 Ω
Range/Resolution6.000 kΩ / 0.001 kΩ
Range/Resolution60.00 kΩ / 0.01 kΩ
Range/Resolution600.0 kΩ / 0.1 kΩ
Range/Resolution6.000 MΩ / 0.001 MΩ
Accuracy0.9 % + 1
Range/Resolution40.00 MΩ / 0.01 MΩ
Accuracy1.5 % + 2
Diode Test
Range/Resolution2.000 V / 0.001 V
Accuracy0.9% + 2
Capacitance
Range/Resolution1000 nF / 1 nF
Range/Resolution10.00 μF / 0.01 μF
Range/Resolution100.0 μF / 0.1 μF
Range/Resolution9999 μF / 1 μF
Range/Resolution100 μF to 1000 μF
Accuracy1.9% + 2
Range/Resolution> 1000 μF
Accuracy5% + 20%
LoZ capacitance
Range1 nF to 500 μF
Accuracy10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution-40 °C to 400 °C / 0.1 °C
Accuracy1% + 102
Range/Resolution-40 °F to 752 °C / 0.2 °F
Accuracy1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution600.0 μA / 0.1 μA
Accuracy1.0% + 2
DC μamps
Range/Resolution600.0 μA / 0.1 μA
Accuracy1.0% + 2
Hz (V or A input)2
Range/Resolution99.99 Hz / 0.01 Hz
Range/Resolution999.99 Hz / 0.1 Hz
Range/Resolution9.999 Hz / 0.001 Hz
Range/Resolution50.00 Hz / 0.01 Hz
Accuracy0.1% + 2

Notes:
1) All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.

Mechanical & General Specifications
Size
Height27.62 cm (10.875")
Length15.875 cm (6.25")
Width5.6 cm (2.203")
Weight

607 g (1.34 lbs)
Warranty

3 years


Fluke 62 MAX+ Specifications

Specifications

Temperature Range

Fluke 62 MAX -30 °C to 500 °C (-22 °F to 932 °F)
Fluke 62+ MAX -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
Fluke 62 MAX ±1.5 °C or ±1.5% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Fluke 62+ MAX ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX <500 ms (95% of reading)
Fluke 62+ MAX <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

Fluke 62 MAX 10:1 (calculated at 90% energy)
Fluke 62+ MAX 12:1 (calculated at 90% energy)
Display Resolution
0.1 °C (0.2 °F)
Repeatability of Readings
Fluke 62 MAX ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater
Fluke 62+ MAX ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
AA battery
Battery Life
Fluke 62 MAX 10 hours with laser and backlight on
Fluke 62+ MAX 8 hours with laser and backlight on

Physical Specifications

Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II
Click here for complete specifications on the Fluke 116/62-MAX+

What's included with the Fluke 116/62-MAX+

  • Fluke 116 HVAC Multimeter with Temperature and Microamps.
  • TL75 Hard Point Test Lead Set.
  • TPak ToolPak Magnetic Meter Hanging Strap.
  • Flexible Cuff Pipe Clamp Thermocouple.
  • 80BK Integrated Temperature Probe.
  • 80AK-A Thermocouple Adapter.
  • C115 Deluxe Soft Carrying Case with Shoulder Strap.
  • Fluke 62 MAX+ Infrared Thermometer

Click on a category to view a selection of compatible accessories with the Fluke 116/62 MAX+ HVAC Multimeter and IR Thermometer Combo Kit.

-
Fluke TL225 SureGrip Stray Voltage Adapter Test Lead Kit TL225
Voltage Adapter Test Lead Kit makes sure the meter has a low input impedance that eliminates stray voltages and indicates real voltage.




Ask a question about Fluke 116/62 MAX+ HVAC Multimeter and IR Thermometer Combo Kit

Review the Fluke Corporation 116/62-MAX+

" data-description="The complete solution to HVAC troubleshooting. The kit includes Fluke 116 Digital Multimeter, Fluke 62 MAX+ Infrared Thermometer, and a range of accessories.">

More Fluke Products