Fluke Networks MFTK-DC MM/SM KIT Data Center MM 850 and SM 1310 MPO Troubleshooting Kit

Model: MFTK-DC MM/SM KIT | UPC: 195112144923

Fluke Networks MFTK-DC MM/SM KIT Data Center MM 850 and SM 1310 MPO Troubleshooting Kit

Model: MFTK-DC MM/SM KIT | UPC: 195112144923

MultiFiber Pro Optical Power Meter and Source is the first fiber tester that can certify MPO fiber trunks without the use of fan-out  cords. This single mode and multimode MPO fiber testing kit eliminates the complexity of polarity issues, and it makes cassettes easier to test in the field. Whether using 10 Gbps preterminated MPO fiber trunks or planning for next-generation 40/100 Gbps Ethernet performance, data centers are standardizing on an MPO connector solution.

MultiFiber Pro Optical Power Meter and Source is the first fiber tester that can certify MPO fiber trunks without the use of fan-out  cords. This single mode and multimode MPO fiber testing kit eliminates the complexity of polarity issues, and it makes cassettes easier to test in the field. Whether using 10 Gbps preterminated MPO fiber trunks or planning for next-generation 40/100 Gbps Ethernet performance, data centers are standardizing on an MPO connector solution.

Your Price $41146.42 CAD
Availability 2 to 3 Weeks
Quantity

Fluke Networks MFTK-DC MM/SM KIT Offers

Typical data center fiber installation means time-consuming, manual, and imprecise MPO validation. MultiFiber Pro Optical Power Meter and Source is 90 percent faster than single fiber cable certification because it measures power loss and validates polarity on 12 fibers in a single connector — reducing test time from weeks to days.

Features

  • "Scan All" Function:

The Scan All function in the MultiFiber Pro Power Meter automatically scans and tests all 12 fibers in MPO connectors – taking just 6 seconds to complete all loss or power measurements. This feature automates the certification of MPO terminated fibers and eliminates the time consuming and manual process of moving the fiber tester from fiber to fiber while using fan-out cords.

  • Built-In Polarity Verification:

The simple purpose of any polarity scheme is to provide a continuous connection from the link’s transmitter to the link’s receiver. For array connectors, TIA-568-C.0 defines three methods to accomplish this: Methods A, B and C. Deployment mistakes are common because these methods require a combination of patch cords with different polarity types. The polarity measurement of MultiFiber Pro allows the user to test individual patch cords, permanent links and channels for correct polarity.

  • On-Board MPO Connector:

Equipped with MPO connector on both the Optical Power Meter and Light Source, it eliminates the use of costly and complicated fan-out cords to test MPO fibers.

Uncovered ports can put cabling, equipment and testers at risk for contamination and affect performance. Ensuring a covered connection on your tester can protect it from dirt and dust. MultiFiber Pro makes it easy by shuttering the MPO connector giving you greater test reliability and peace of mind.

  • Simple User Interface:

The MultiFiber Pro is so successful at simplifying the task of simultaneously representing polarity, power and loss results for 12 fibers that the user interface is patent pending. The power meter enables the users to easily comprehend the measurement results of 12 fibers simultaneously. The light source identifies each fiber within the MPO connector that is being tested. Any individual measurement that fails the test limit is plainly identified to allow root-cause analysis. This powerful yet straightforward test set enables everyone to become a fiber testing expert and increases efficiency in testing data center projects.

  • Select an Individual Fiber:

One of the main problems in the data center is the ability to drill down to a single fiber during testing and troubleshooting. MultiFiber Pro can troubleshoot a single fiber within an MPO trunk and provide a single fiber test result. This ability increases MPO connector verification and troubleshooting flexibility with more precise, per-fiber data and reporting.

  • Easy Reporting:

The MultiFiber Pro Power Meter stores up to 3,000 test results (or the equivalent of 250 MPO cables) internally which can be uploaded to a PC using the LinkWare™ 7 Cable Test Management Software. LinkWare 7 allows you to manage test results, edit cable ID’s, print professional reports and even export the data into spreadsheet formats.

  • FI-7000 FiberInspector Pro with MPO tip and cleaning supplies:
  • The FI-7000 is the ultimate inspection tool. It enables you to quickly inspect and certify fiber end-faces inside ports or patch cords. It’s 2-second automated PASS/FAIL eliminates human subjectivity and enables anyone to become a fiber inspection expert.
  • Automated Pass/Fail acceptance testing of fiber end-faces
  • Large touchscreen for pinch and zoom
  • Graphical indication of problem areas due to contamination, pits, chips, and scratches
  • Certify to industry standards - IEC 61300-3-35
  • Eliminate human subjectivity from end-face measurements
  • Includes MPO tip for inspection probe and MPO cleaner

Fluke Networks MFTK-DC MM/SM KIT Specifications

Environemtnal Specifications
Operating temperature -10ºC to +50ºC
Storage temperature -20ºC to +50ºC
Operating humidity 95% (10ºC to +35ºC) non-condensing 75% (35ºC to +45ºC) non-condensing Uncontrolled <10ºC
Operating altitude 4,000 m
Storage altitude 12,000 m
Vibration Random 2 G, 5 Hz to 500 Hz
Optical Power Meter (Specifications apply at 23ºC (73ºF), unless otherwise noted.)
Detector type InGaAs
Calibrated wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Measurement range 0 dBm to -50 dBm
Test time / Power measurement linearity 6 seconds ±0.1 dB2
Power measurement uncertainty ±0.35 dB2
Power measurement repeatability < 0.10 dB2
Display resolution, dB or dBm 0.01
Power display units dBm, mW, µW
User-selectable limit for loss 0.05 dB to 50.0 dB, in increments of 0.05 dB up to 10.0 dB and 0.1 dB up to 50.0dB
Auto wavelength detection Yes
Polarity detection Detects A, B, C, and Corning Plug & Play™ Universal Systems polarities
2 kHz detection Yes
Record storage 3000 records, one fiber per record (250 12-fiber cables)
External interface USB 2.0, full speed
Optical connector MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm, 50 µm, and singlemode fibers. Connector has a self-closing, protective cover.
Power requirement 2 x AA alkaline batteries
Battery life3 30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm)
Weight 10.9 oz (309 g)

What's included with the Fluke Networks MFTK-DC MM/SM KIT

  • MultiFiber Pro Power Meter
  • 850 nm Light Source
  • 1310 nm Light Source
  • Test Reference Cords
  • MPO adapters
  • Magnetic strap attachment
  • FI-3000 FiberInspector™ Ultra camera
  • Tip Set (12/24 UPC and 12/24 APC)
  • Single Fiber Adapter for FI-1000 tips
  • AC charger
  • Getting Started Guide
  • Holster
  • FI-1000 Tip Kit
  • FiberLert Live Fiber Detector
  • FI-3000TP-AMPO-12-32 keyless MPO inspection tip
  • 5 x 12/24 MPO QuickClean endface cleaners
  • Versiv "cube" soft-sided carry case

Ask a question about Fluke Networks MFTK-DC MM/SM KIT Data Center MM 850 and SM 1310 MPO Troubleshooting Kit

Customer Reviews for the Fluke Networks MFTK-DC MM/SM KIT

Fluke Networks MFTK-DC MM/SM KIT Offers

Typical data center fiber installation means time-consuming, manual, and imprecise MPO validation. MultiFiber Pro Optical Power Meter and Source is 90 percent faster than single fiber cable certification because it measures power loss and validates polarity on 12 fibers in a single connector — reducing test time from weeks to days.

Features

  • "Scan All" Function:

The Scan All function in the MultiFiber Pro Power Meter automatically scans and tests all 12 fibers in MPO connectors – taking just 6 seconds to complete all loss or power measurements. This feature automates the certification of MPO terminated fibers and eliminates the time consuming and manual process of moving the fiber tester from fiber to fiber while using fan-out cords.

  • Built-In Polarity Verification:

The simple purpose of any polarity scheme is to provide a continuous connection from the link’s transmitter to the link’s receiver. For array connectors, TIA-568-C.0 defines three methods to accomplish this: Methods A, B and C. Deployment mistakes are common because these methods require a combination of patch cords with different polarity types. The polarity measurement of MultiFiber Pro allows the user to test individual patch cords, permanent links and channels for correct polarity.

  • On-Board MPO Connector:

Equipped with MPO connector on both the Optical Power Meter and Light Source, it eliminates the use of costly and complicated fan-out cords to test MPO fibers.

Uncovered ports can put cabling, equipment and testers at risk for contamination and affect performance. Ensuring a covered connection on your tester can protect it from dirt and dust. MultiFiber Pro makes it easy by shuttering the MPO connector giving you greater test reliability and peace of mind.

  • Simple User Interface:

The MultiFiber Pro is so successful at simplifying the task of simultaneously representing polarity, power and loss results for 12 fibers that the user interface is patent pending. The power meter enables the users to easily comprehend the measurement results of 12 fibers simultaneously. The light source identifies each fiber within the MPO connector that is being tested. Any individual measurement that fails the test limit is plainly identified to allow root-cause analysis. This powerful yet straightforward test set enables everyone to become a fiber testing expert and increases efficiency in testing data center projects.

  • Select an Individual Fiber:

One of the main problems in the data center is the ability to drill down to a single fiber during testing and troubleshooting. MultiFiber Pro can troubleshoot a single fiber within an MPO trunk and provide a single fiber test result. This ability increases MPO connector verification and troubleshooting flexibility with more precise, per-fiber data and reporting.

  • Easy Reporting:

The MultiFiber Pro Power Meter stores up to 3,000 test results (or the equivalent of 250 MPO cables) internally which can be uploaded to a PC using the LinkWare™ 7 Cable Test Management Software. LinkWare 7 allows you to manage test results, edit cable ID’s, print professional reports and even export the data into spreadsheet formats.

  • FI-7000 FiberInspector Pro with MPO tip and cleaning supplies:
  • The FI-7000 is the ultimate inspection tool. It enables you to quickly inspect and certify fiber end-faces inside ports or patch cords. It’s 2-second automated PASS/FAIL eliminates human subjectivity and enables anyone to become a fiber inspection expert.
  • Automated Pass/Fail acceptance testing of fiber end-faces
  • Large touchscreen for pinch and zoom
  • Graphical indication of problem areas due to contamination, pits, chips, and scratches
  • Certify to industry standards - IEC 61300-3-35
  • Eliminate human subjectivity from end-face measurements
  • Includes MPO tip for inspection probe and MPO cleaner

Fluke Networks MFTK-DC MM/SM KIT Specifications

Environemtnal Specifications
Operating temperature -10ºC to +50ºC
Storage temperature -20ºC to +50ºC
Operating humidity 95% (10ºC to +35ºC) non-condensing 75% (35ºC to +45ºC) non-condensing Uncontrolled <10ºC
Operating altitude 4,000 m
Storage altitude 12,000 m
Vibration Random 2 G, 5 Hz to 500 Hz
Optical Power Meter (Specifications apply at 23ºC (73ºF), unless otherwise noted.)
Detector type InGaAs
Calibrated wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Measurement range 0 dBm to -50 dBm
Test time / Power measurement linearity 6 seconds ±0.1 dB2
Power measurement uncertainty ±0.35 dB2
Power measurement repeatability < 0.10 dB2
Display resolution, dB or dBm 0.01
Power display units dBm, mW, µW
User-selectable limit for loss 0.05 dB to 50.0 dB, in increments of 0.05 dB up to 10.0 dB and 0.1 dB up to 50.0dB
Auto wavelength detection Yes
Polarity detection Detects A, B, C, and Corning Plug & Play™ Universal Systems polarities
2 kHz detection Yes
Record storage 3000 records, one fiber per record (250 12-fiber cables)
External interface USB 2.0, full speed
Optical connector MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm, 50 µm, and singlemode fibers. Connector has a self-closing, protective cover.
Power requirement 2 x AA alkaline batteries
Battery life3 30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm)
Weight 10.9 oz (309 g)

What's included with the Fluke Networks MFTK-DC MM/SM KIT

  • MultiFiber Pro Power Meter
  • 850 nm Light Source
  • 1310 nm Light Source
  • Test Reference Cords
  • MPO adapters
  • Magnetic strap attachment
  • FI-3000 FiberInspector™ Ultra camera
  • Tip Set (12/24 UPC and 12/24 APC)
  • Single Fiber Adapter for FI-1000 tips
  • AC charger
  • Getting Started Guide
  • Holster
  • FI-1000 Tip Kit
  • FiberLert Live Fiber Detector
  • FI-3000TP-AMPO-12-32 keyless MPO inspection tip
  • 5 x 12/24 MPO QuickClean endface cleaners
  • Versiv "cube" soft-sided carry case

Ask a question about Fluke Networks MFTK-DC MM/SM KIT Data Center MM 850 and SM 1310 MPO Troubleshooting Kit

Customer Reviews for the Fluke Networks MFTK-DC MM/SM KIT

More Fluke Networks Products