5A Clamp-on CT for Fluke 434. Part # i5S.
Our rentals come fully calibrated to traceable standards. Have your own instrument? We also offer calibration services for this model (CERTICM1).
5A Clamp-on CT for Fluke 434. Part # i5S.
Our rentals come fully calibrated to traceable standards. Have your own instrument? We also offer calibration services for this model (CERTICM1).
Expand the use of your Fluke 430 series power quality tool with this 5 A ac current clamp, specially configured to provide low current accuracy while taking measurements on secondary current transformers.
| Specifications | |||||||
| Nominal current range |
|
||||||
| 0.20833333333333334 | |||||||
| Continuous current range |
|
||||||
| 10 mA to 6 A | |||||||
| Maximum Non-Destructive Current |
|
||||||
| 70 A | |||||||
| Lowest measurable current |
|
||||||
| 10 mA | |||||||
| Basic Accuracy |
|
||||||
| 48 Hz to 65 Hz | |||||||
| 10 mA to 1 A | 1% + 5 mA | ||||||
| 1 A to 5 A | 0.01 | ||||||
| Useable frequency |
|
||||||
| 40 Hz to 5 kHz | |||||||
| Output level(s) |
|
||||||
| 400 mV/A | |||||||
| Input Load Impedance |
|
||||||
| > 1 MΩ in parallel with up to 47 pF | |||||||
| Crest Factor |
|
||||||
| ≤ 3, add 0.7% to accuracy | |||||||
| Safety Specifications | |||||||
| Safety |
|
||||||
| CAT III 600 V per IEC/EN61010-1, Pollution Degree 2 | |||||||
| Maximum voltage |
|
||||||
| 600 V ac | |||||||
| Mechanical & General Specifications | |||||||
| Warranty |
|
||||||
| 1 year | |||||||
| Maximum conductor diameter |
|
||||||
| 15 mm | |||||||
| Output cable length |
|
||||||
| 2.5 m | |||||||
| BNC Adapter |
|
||||||
| Yes | |||||||
| BNC to banana adapter included |
|
||||||
| No | |||||||
| Specifications | |||||||
| Nominal current range |
|
||||||
| 0.20833333333333334 | |||||||
| Continuous current range |
|
||||||
| 10 mA to 6 A | |||||||
| Maximum Non-Destructive Current |
|
||||||
| 70 A | |||||||
| Lowest measurable current |
|
||||||
| 10 mA | |||||||
| Basic Accuracy |
|
||||||
| 48 Hz to 65 Hz | |||||||
| 10 mA to 1 A | 1% + 5 mA | ||||||
| 1 A to 5 A | 0.01 | ||||||
| Useable frequency |
|
||||||
| 40 Hz to 5 kHz | |||||||
| Output level(s) |
|
||||||
| 400 mV/A | |||||||
| Input Load Impedance |
|
||||||
| > 1 MΩ in parallel with up to 47 pF | |||||||
| Crest Factor |
|
||||||
| ≤ 3, add 0.7% to accuracy | |||||||
| Safety Specifications | |||||||
| Safety |
|
||||||
| CAT III 600 V per IEC/EN61010-1, Pollution Degree 2 | |||||||
| Maximum voltage |
|
||||||
| 600 V ac | |||||||
| Mechanical & General Specifications | |||||||
| Warranty |
|
||||||
| 1 year | |||||||
| Maximum conductor diameter |
|
||||||
| 15 mm | |||||||
| Output cable length |
|
||||||
| 2.5 m | |||||||
| BNC Adapter |
|
||||||
| Yes | |||||||
| BNC to banana adapter included |
|
||||||
| No | |||||||