Solar Panel Tester and I-V Curve Tracer with Temperature Measurements.
Solar Panel Tester and I-V Curve Tracer with Temperature Measurements.
Features
Applications
| Electrical Measurement | |
| Maximum Power Value (Pmax) | Range: 0 W to 800 W Accuracy: ±5% |
| Voltage at MMPT point (Vmax) | Range: 0 V to 60 V Accuracy: ±5% |
| Current at MMPT point (Imax) | Range: 0 A to 30 A Accuracy: ±5% |
| Open Circuit Voltage (VOC) | Range: 0 V to 60 V Accuracy: ±1% |
| Short Circuit Current (ISC) | Range: 0 A to 30 A Accuracy: ±1% |
| Device Temperature Protection | Range: 0°C to 60°C Accuracy: ±3% |
| Measuring rate | 3 samples per second |
| Power System | |
| Display | TFT Display |
| Backlight | White LED array |
| Warranty | Limited 3-Year Warranty |
| Calibration cycle | Once per year, recommended |
| Certifications | |
| Certifications | CE, RCM, FCC |
| Safety standards | IEC 61010-1 |
| EMC standards | EN61326-1 |
| Environmental Data | |
| Operating ambient temp & RH | −10°C to 50°C (14°F to 122°F), <80% RH |
| Storage temperature and RH | −20°C to 60°C (−4°F to 140°F), 0 to 80% RH |
| Operating altitude | 2000 m (6560 ft) |
| Pollution degree | 2 |
| Meter Physical Data | |
| Dimensions | 151.6 mm × 72.5 mm × 38 mm (5.97 in × 2.85 in × 1.50 in) |
| Weight | 206 g (0.45 lbs) |
Click on a category to view a selection of compatible accessories with the FLIR PV48 Solar Panel I-V Curve Tracer.
| Electrical Measurement | |
| Maximum Power Value (Pmax) | Range: 0 W to 800 W Accuracy: ±5% |
| Voltage at MMPT point (Vmax) | Range: 0 V to 60 V Accuracy: ±5% |
| Current at MMPT point (Imax) | Range: 0 A to 30 A Accuracy: ±5% |
| Open Circuit Voltage (VOC) | Range: 0 V to 60 V Accuracy: ±1% |
| Short Circuit Current (ISC) | Range: 0 A to 30 A Accuracy: ±1% |
| Device Temperature Protection | Range: 0°C to 60°C Accuracy: ±3% |
| Measuring rate | 3 samples per second |
| Power System | |
| Display | TFT Display |
| Backlight | White LED array |
| Warranty | Limited 3-Year Warranty |
| Calibration cycle | Once per year, recommended |
| Certifications | |
| Certifications | CE, RCM, FCC |
| Safety standards | IEC 61010-1 |
| EMC standards | EN61326-1 |
| Environmental Data | |
| Operating ambient temp & RH | −10°C to 50°C (14°F to 122°F), <80% RH |
| Storage temperature and RH | −20°C to 60°C (−4°F to 140°F), 0 to 80% RH |
| Operating altitude | 2000 m (6560 ft) |
| Pollution degree | 2 |
| Meter Physical Data | |
| Dimensions | 151.6 mm × 72.5 mm × 38 mm (5.97 in × 2.85 in × 1.50 in) |
| Weight | 206 g (0.45 lbs) |
Click on a category to view a selection of compatible accessories with the FLIR PV48 Solar Panel I-V Curve Tracer.