The FH669R9PTU is a multispectral fixed camera that integrates industry-leading thermal imaging with 4K visible imaging to provide rapid visual verification of hot spots in early fire detection applications. The Pan-Tilt Unit provides precise, computer-controlled movement for the camera, allowing it to pan (rotate horizontally) and tilt (rotate vertically) to cover a wider area or track a target precisely. This mechanism is crucial for applications such as surveillance, object tracking, and remote sensing, as it enables multi-angular observation over a wide area from a fixed location, providing flexibility and comprehensive coverage.
The FH669R9PTU is a multispectral fixed camera that integrates industry-leading thermal imaging with 4K visible imaging to provide rapid visual verification of hot spots in early fire detection applications. The Pan-Tilt Unit provides precise, computer-controlled movement for the camera, allowing it to pan (rotate horizontally) and tilt (rotate vertically) to cover a wider area or track a target precisely. This mechanism is crucial for applications such as surveillance, object tracking, and remote sensing, as it enables multi-angular observation over a wide area from a fixed location, providing flexibility and comprehensive coverage.
The integration of a visible (optical) sensor alongside the thermal sensor provides a dual-verification system that allows operators to validate thermal alarms visually, reducing uncertainty and speeding decision-making. Because it can detect localized temperature anomalies even before visible smoke or flame appears, it gives advance warning, enabling preventative response rather than reactive suppression. Integrated radiometric temperature measurement means it can also support applications beyond pure fire detection, such as condition monitoring of equipment, panels, or structures, giving multipurpose value.
Rapid detection and visual verification
Intelligent alarms
Easy integration
Applications
| Thermal Sensor and Optique | |
| Array format (NTSC) | 640 × 512, 320 × 256 |
| Detector type | Long-life, uncooled VOx microbolometer |
| Pixel pitch | 17 μm |
| Thermal frame rate | NTSC: 30 Hz or PAL: 25 Hz / 8.3 Hz |
| Optical Characteristics | FOV: 69° × 56° Focal Length: 9 mm F/#: F1.4 |
| Spectral Range | 7.5 μm to 13.5 μm |
| Sensitivity (NETD) | <35 mK @ 77°F (25°C) F# 1.0 |
| Optical Characteristics | FOV: 98° × 55° Focal length: 3.6 to 10 mm F/#: 1.5 to 2.8 |
| Temperature Measurement | |
| Measurement accuracy | Target below 212°F (100°C): ±9°F (±5°C) accuracy Target below 302°F (150°C): ±5% accuracy Target above 302°F (150°C): ±15% accuracy |
| Measurement note | Measured at 77°F (25°C) ambient temperature. Error may be greater at extreme temperatures |
| Object temperature range | High gain mode: 32 to 320°F (0 to 160°C) Low gain mode: 32 to 716°F (0 to 380°C) |
| Video | |
| Video type | IP and analog video |
| Sensitivity | Color: 0.25 Lux (@ f1.6 AGC On, 30 fps) B/W: 0.10 Lux (@ f1.6 AGC On, 30 fps) |
| Visible frame rate | 30 Hz |
| Video compression | Two independent channels of H.264/H.265 or M-JPEG (except 4K) for visible and thermal |
| Streaming resolution (Primary stream) | Thermal: VGA (640 × 512), QVGA (320 × 256) Visible: 4K (3840 × 2160), 1080p (1920 × 1080), 720p (1280 × 720), VGA (640 × 480) |
| Streaming resolution (Secondary stream) | Thermal: VGA (640 × 512), QVGA (320 × 256) Visible: 1080p (1920 × 1080), 720p (1280 × 720), VGA (640 × 480) |
| Thermal image settings | Auto AGC, Dynamic Detail Enhancement (DDE), Brightness, Contrast |
| Thermal AGC region of interest (ROI) | Default, Presets and User definable to insure optimal image quality on subjects of interest |
| Image uniformity optimization | Automatic Flat Field Correction (FFC) – Thermal and Temporal Triggers |
| Intégration de systèmes | |
| Ethernet | 100/1000 Mbps |
| Network APIs | NEXUS® SDK NEXUS® CGI ONVIF Profile S, G, T |
| Digital I/O | Input: Two dry alarm contacts Output: Two relay contacts, 1 A max at 24 V AC / 30 V DC Configurable between normally open and normally closed |
| Supported protocols | IPV4, HTTP, HTTPS, UPnP, DNS, NTP, RTSP, TCP, UDP, ICMP, IGMP, DHCP, ARP, IEEE 802.1X |
| Input voltage | ±12 V DC (10%) ±24 V DC (10%) ±24 V AC (10%) 802.3bt |
| Power consumption | Nominal: 15 W Heaters enabled, 12 V CC: 48 W Heaters enabled, all other inputs: 70 W |
| Environnemental | |
| IP rating (dust & water ingress) | IP66, IP67 |
| Operating temperature range | -40 to 158°F (-40 to 70°C) |
| Storage temperature range | -67 to 185°F (-55 to 85°C) |
| Corrosion | MIL-STD 810G, 1000 hr salt spray |
| Humidity | 0 to 95% relative |
| Shock | IEC 60068-2-27 |
| Vibration | IEC 60068-2-64 |
| Vandalism | IK10 (except Windows) |
| Surge immunity on AC power lines | EN 50130-4 |
| Surge immunity on signal lines | EN 50130-4 |
| Surge/lightning protection | TVS 6000 V lightning protection, surge protection, voltage transient protection |
| Général | |
| Compliance and Certifications | FCC Part 15 (Subpart B, class A) CE Marked RoHS IP66 WEEE IEC 62368 ONVIF Profile S, G, T |
| Video Analytics | Region entrance/Intrusion detection Tampering Loitering CNN classifier |
| Cybersecurity | IEEE 802.1X TLS/HTTPS User authentication Access control via firewall User credentials with policy enforcement Digest authentication |
| Thermal Sensor and Optique | |
| Array format (NTSC) | 640 × 512, 320 × 256 |
| Detector type | Long-life, uncooled VOx microbolometer |
| Pixel pitch | 17 μm |
| Thermal frame rate | NTSC: 30 Hz or PAL: 25 Hz / 8.3 Hz |
| Optical Characteristics | FOV: 69° × 56° Focal Length: 9 mm F/#: F1.4 |
| Spectral Range | 7.5 μm to 13.5 μm |
| Sensitivity (NETD) | <35 mK @ 77°F (25°C) F# 1.0 |
| Optical Characteristics | FOV: 98° × 55° Focal length: 3.6 to 10 mm F/#: 1.5 to 2.8 |
| Temperature Measurement | |
| Measurement accuracy | Target below 212°F (100°C): ±9°F (±5°C) accuracy Target below 302°F (150°C): ±5% accuracy Target above 302°F (150°C): ±15% accuracy |
| Measurement note | Measured at 77°F (25°C) ambient temperature. Error may be greater at extreme temperatures |
| Object temperature range | High gain mode: 32 to 320°F (0 to 160°C) Low gain mode: 32 to 716°F (0 to 380°C) |
| Video | |
| Video type | IP and analog video |
| Sensitivity | Color: 0.25 Lux (@ f1.6 AGC On, 30 fps) B/W: 0.10 Lux (@ f1.6 AGC On, 30 fps) |
| Visible frame rate | 30 Hz |
| Video compression | Two independent channels of H.264/H.265 or M-JPEG (except 4K) for visible and thermal |
| Streaming resolution (Primary stream) | Thermal: VGA (640 × 512), QVGA (320 × 256) Visible: 4K (3840 × 2160), 1080p (1920 × 1080), 720p (1280 × 720), VGA (640 × 480) |
| Streaming resolution (Secondary stream) | Thermal: VGA (640 × 512), QVGA (320 × 256) Visible: 1080p (1920 × 1080), 720p (1280 × 720), VGA (640 × 480) |
| Thermal image settings | Auto AGC, Dynamic Detail Enhancement (DDE), Brightness, Contrast |
| Thermal AGC region of interest (ROI) | Default, Presets and User definable to insure optimal image quality on subjects of interest |
| Image uniformity optimization | Automatic Flat Field Correction (FFC) – Thermal and Temporal Triggers |
| Intégration de systèmes | |
| Ethernet | 100/1000 Mbps |
| Network APIs | NEXUS® SDK NEXUS® CGI ONVIF Profile S, G, T |
| Digital I/O | Input: Two dry alarm contacts Output: Two relay contacts, 1 A max at 24 V AC / 30 V DC Configurable between normally open and normally closed |
| Supported protocols | IPV4, HTTP, HTTPS, UPnP, DNS, NTP, RTSP, TCP, UDP, ICMP, IGMP, DHCP, ARP, IEEE 802.1X |
| Input voltage | ±12 V DC (10%) ±24 V DC (10%) ±24 V AC (10%) 802.3bt |
| Power consumption | Nominal: 15 W Heaters enabled, 12 V CC: 48 W Heaters enabled, all other inputs: 70 W |
| Environnemental | |
| IP rating (dust & water ingress) | IP66, IP67 |
| Operating temperature range | -40 to 158°F (-40 to 70°C) |
| Storage temperature range | -67 to 185°F (-55 to 85°C) |
| Corrosion | MIL-STD 810G, 1000 hr salt spray |
| Humidity | 0 to 95% relative |
| Shock | IEC 60068-2-27 |
| Vibration | IEC 60068-2-64 |
| Vandalism | IK10 (except Windows) |
| Surge immunity on AC power lines | EN 50130-4 |
| Surge immunity on signal lines | EN 50130-4 |
| Surge/lightning protection | TVS 6000 V lightning protection, surge protection, voltage transient protection |
| Général | |
| Compliance and Certifications | FCC Part 15 (Subpart B, class A) CE Marked RoHS IP66 WEEE IEC 62368 ONVIF Profile S, G, T |
| Video Analytics | Region entrance/Intrusion detection Tampering Loitering CNN classifier |
| Cybersecurity | IEEE 802.1X TLS/HTTPS User authentication Access control via firewall User credentials with policy enforcement Digest authentication |