EV Charger Test Adapter with NACS Plug and Type 1 Converter.
EV Charger Test Adapter with NACS Plug and Type 1 Converter.
Features
Applications
| Electrical Measurement | |
| PE Pre-Test | Pass / Fault (>50 V AC/DC between PE conductor and touch sensor) |
| PP State Indication | Open, 13 A, 20 A, 32 A, 63 A |
| CP State Simulation | A (Disconnected) , B (Connected) , C (Charging), D (Charging w/ ventilation), E (Error) |
| Voltage Phase Indication | L1, L2 |
| CP Error (E State) Simulation | Pass / Fault (CP signal short-circuited to PE) |
| PE Error Simulation | Pass / Fault (Interruption of PE conductor) |
| RCD/CCID Trip Test | Pass / Fault (Test RCD/CCID activation once tripped) |
| Outputs (For Test Purpose Only) | |
| Measuring Terminals L1, PE, N | Maximum 250 V (Single Phase), 50/60 Hz, CAT II 300 V, Maximum 10 A |
| Outputs (Optional Meters) | |
| Connect to CMM (DM286) | CP State C / D for AC Voltage with Hz measurement |
| Connect to Insulation Tester (IM75-2) | CP State B for EV cable Insulation Test |
| Power System | |
| Battery | 4 × AA Alkaline batteries |
| Battery Life | Approximately 100 hours, with alkaline batteries |
| General Information | |
| NACS Connector (Built-In) | Connector for NACS Station |
| Accessory Converter | NACS to SAE J1772 Type 1 |
| Category Rating | CAT II-300 V |
| Warranty | Limited 3-Year Warranty |
| Certifications | |
| Certifications | ETL, CE |
| Safety Standards | IEC 61010-1 CAT II-300 V |
| EMC Standards | EN61326-1 |
| Environmental Data | |
| Operating Ambient Temperatures and Relative Humidity | −10°C to 30°C (14°F to 86°F), <85% RH 30°C to 40°C (86°F to 104°F), <75% RH 40°C to 50°C (104°F to 122°F), <45% RH |
| Storage Temperature and RH | −20°C to 60°C (−4°F to 140°F), 0 to 80% RH (without batteries) |
| Operating Altitude | 2000 m (6560') |
| Pollution Degree | 2 |
| Meter Physcial Data | |
| Dimensions | 237 mm × 65 mm × 56 mm (9.33" × 2.56" × 2.20") |
| Weight | 600 g (1.32 lbs) |
| Electrical Measurement | |
| PE Pre-Test | Pass / Fault (>50 V AC/DC between PE conductor and touch sensor) |
| PP State Indication | Open, 13 A, 20 A, 32 A, 63 A |
| CP State Simulation | A (Disconnected) , B (Connected) , C (Charging), D (Charging w/ ventilation), E (Error) |
| Voltage Phase Indication | L1, L2 |
| CP Error (E State) Simulation | Pass / Fault (CP signal short-circuited to PE) |
| PE Error Simulation | Pass / Fault (Interruption of PE conductor) |
| RCD/CCID Trip Test | Pass / Fault (Test RCD/CCID activation once tripped) |
| Outputs (For Test Purpose Only) | |
| Measuring Terminals L1, PE, N | Maximum 250 V (Single Phase), 50/60 Hz, CAT II 300 V, Maximum 10 A |
| Outputs (Optional Meters) | |
| Connect to CMM (DM286) | CP State C / D for AC Voltage with Hz measurement |
| Connect to Insulation Tester (IM75-2) | CP State B for EV cable Insulation Test |
| Power System | |
| Battery | 4 × AA Alkaline batteries |
| Battery Life | Approximately 100 hours, with alkaline batteries |
| General Information | |
| NACS Connector (Built-In) | Connector for NACS Station |
| Accessory Converter | NACS to SAE J1772 Type 1 |
| Category Rating | CAT II-300 V |
| Warranty | Limited 3-Year Warranty |
| Certifications | |
| Certifications | ETL, CE |
| Safety Standards | IEC 61010-1 CAT II-300 V |
| EMC Standards | EN61326-1 |
| Environmental Data | |
| Operating Ambient Temperatures and Relative Humidity | −10°C to 30°C (14°F to 86°F), <85% RH 30°C to 40°C (86°F to 104°F), <75% RH 40°C to 50°C (104°F to 122°F), <45% RH |
| Storage Temperature and RH | −20°C to 60°C (−4°F to 140°F), 0 to 80% RH (without batteries) |
| Operating Altitude | 2000 m (6560') |
| Pollution Degree | 2 |
| Meter Physcial Data | |
| Dimensions | 237 mm × 65 mm × 56 mm (9.33" × 2.56" × 2.20") |
| Weight | 600 g (1.32 lbs) |