Fieldpiece SM382V SMAN 3-Port Wireless Digital Refrigerant Manifold

Model: SM382V | UPC: 872641005498

Fieldpiece SM382V SMAN 3-Port Wireless Digital Refrigerant Manifold

Model: SM382V | UPC: 872641005498

SM382V SMAN is the newly designed wireless, three-port, manifold with a built-in micron gauge to check, evaluate, and charge A/C systems. Fieldpiece is committed to creating the toughest, most advanced digital refrigerant manifold providing the ultimate field performance for A/C and refrigeration specialists.

SM382V SMAN is the newly designed wireless, three-port, manifold with a built-in micron gauge to check, evaluate, and charge A/C systems. Fieldpiece is committed to creating the toughest, most advanced digital refrigerant manifold providing the ultimate field performance for A/C and refrigeration specialists.

Your Price $842.00 CAD
Availability 5 in Stock
Quantity

Fieldpiece SM382V Offers

The Fieldpiece SM382V digital manifold has been upgraded for ultimate field protection and long-range wireless communication. The Fieldpiece SM382V SMAN manifold includes a fully rubberized case that seals and protects it from dust, bumps, and light rain, and the heavy-duty hook allows you to hang it in your work vehicle or job site. The A/C specialist can view the calculated target superheat while monitoring, in real time, how their change is affecting actual superheat and subcooling. All measurements and live calculations such as pipe temperatures, refrigerant usage, and indoor air temperatures can be viewed on the extra-large 5” LCD screen or a mobile device up to 1000 feet (305 meters) when connected to the Job Link System App. In addition, when using the Job Link App, work can be documented, and reports generated from the smartphone or tablet.
The SMAN 382V includes over 70 refrigerants pre-programmed and a rolling list of the ten most recently used refrigerants stored at the top of the main refrigerant list for quick selection. The current refrigerant is automatically added to this list of ten refrigerants when the manifold powers off.
The Fieldpiece SM382V wireless manifold with micron gauge includes some customizable features, such as adjustable auto power-off duration, and the ability to adjust the backlight duration. In addition, a technician can set high and low vacuum alarms, and select each unit of measurement individually.
A Nitrogen Test (Tightness Test) is available to check for leaks after repairs or on new installs before charging with refrigerant. The timer tracks the duration of the test and temperature is compensated with SL temp to avoid false positives.
Add Job Link® System wireless tools to your arsenal and get live readings directly on the SMAN® manifold screen from the Job Link Psychrometers (JL3RH), Job Link Pipe Clamps (JL3PC), and SR47 Refrigerant Scale. Place pipe clamps in the perfect location, view live air measurements and calculations while making adjustments, and monitor and record refrigerant weight for precise recovery and charging documentation. Up to nine jobs can be saved to the internal flash drive.
The Fieldpiece SMAN 382 has an extremely durable impact-resistant case, reinforced hook, and hermetically sealed sight glass, and is water-resistant with an IP55 rating. In addition, the three protected thermocouple jacks have been moved to the back for additional protection. Note: Fieldpiece SM382V is a direct replacement of the popular Fieldpiece SMAN380V.

Features

  • Features an integrated vacuum gauge
  • Designed with low profile, lay-flat hose ports for added durability
  • Customizable auto power off, backlight duration
  • Customizable high and low vacuum alarms
  • Includes hermetically sealed sight glass to see refrigerant flow and condition
  • View wireless probe and scale readings
  • Logs up to 168 hours of data
  • Loaded with over 70 refrigerants, including A2Ls
  • Measurements can be viewed on a mobile device up to 1000 feet (305 meters) away
  • Runs a temperature-compensated nitrogen pressure test, with a timer
  • Protected thermocouple jacks for pipe and outdoor temps
  • Super rugged construction
  • Water-resistant (IP55)
  • Serves as a central data hub for Job Link® wireless tools and connects to the Job Link® System App
  • Monitor and record refrigerant weight

Simply Strong

  • The SM382V 2-valve Manifold is simply strong. The heavy-duty casing, reinforced hook, IP55 dust and water resistance, impact resistant screen, protected thermocouple jacks, and hermetically sealed sight glass, all ensure the SMANs are ready to go to work.

Packed with Knowledge

  • The SM382V is designed to work the way you do with advanced features to streamline your job and provide the answers you need.

Measures

  • Line pressures, pipe temperatures, dry bulb temperature, and system vacuum

Calculates

  • Superheat, subcooling, vapor saturation, liquid saturation, and delta T
  • Live target delta T and target evaporator exit temperature with optional Job Link wireless-tools
  • Temperature-compensated pressure differential for nitrogen pressure testing

Data Logs

  • Stores up to 9 jobs internally
  • Logs up to 168 continuous hours

Is Customizable

  • Select the measurements to display
  • Select wireless ON/OFF
  • Set high and low vacuum alarms

Applications

  • Commercial HVAC/R
  • Residential HVAC/R
  • Full System Analysis

Fieldpiece SM382V Specifications

Pressure
Sensor Type Absolute pressure sensors
Port Type (3) 1/4" standard SAE male flare fittings
Pressure Range and Units 870 Psig (English), 60.00 Bar (Metric), 6.000 MPa (Metric), and 6000 kPa (Metric)
Negative Pressure Range and Units 29 inHg (English), 74 cmHg (Metric), 0.98 Bar (Metric)
Resolution 0.1 Psig
0.01 Bar
0.001 MPa
1 kPa
0.1 inHg
1 cmHg
Negative Pressure Accuracy 29 inHg to 0 inHg: ±0.2 inHg
74 cmHg to 0 cmHg: ±1 cmHg0.98 Bar to 0 Bar
±0.01 Bar
Pressure Accuracy ±1 Psig: 0 to 200 Psig
±(0.3% of reading + 1 Psig): 200 to 870 Psig
±0.07 Bar: 0 to 13.78 Bar
±(0.3% of reading + 0.07 Bar): 13.78 to 60.00 Bar
±0.007 MPa: 0 to 1.378 MPa
±(0.3% of reading + 0.007 MPa): 1.378 to 6.000 MPa
±7 kPa: 0 to 1378 kPa
±(0.3% of reading + 7 kPa): 1378 to 6000 kPa
Maximum overload pressure 870 Psig (5998 kPa)
Units Psig, kPa, MPa, bar, inHg, and cmHg
Microns for Vacuum
Sensor Type Thermistor
Port Type 3 x 1/4" standard NPT male flare fittings
Range and Units 50 to 9999 microns of mercury (English)
6.7 to 1330 Pascals (Metric)
0.067 to 13.30 mBar (Metric)
50 to 9999 mTorr (Metric)
0.050 to 9.999 Torr (Metric, equivalent to mmHg)
Resolution 1 micron of mercury (below 2000 microns)
0.1 Pascal (below 250 Pascals)
0.001 mBar (below 2.500 mBar)
1 mTorr (below 2000 mTorr)
0.001 Torr (below 2.000 Torr)
Accuracy at 25°C (77°F) ±(5% of reading + 5 microns of mercury): 50 to 2000 microns
±(5% of reading + 1.0 Pascal): 6.7 to 266.0 Pascal
±(5% of reading + 0.010 mBar): 0.067 to 2.660 mBar
±(5% of reading + 5 mTorr): 50 to 2000 mTorr
±(5% of reading + 0.005 Torr): 0.067 to 2.000 Tor
Maximum Overload pressure 580 psig
Units Microns of mercury
Temperature
Sensor type Type K thermocouple(nickel chromium/nickel aluminum)
Jack Type (3) Type K thermocouple
Range -50 to 257°F (-46 to 125°C), limited by the thermocouplespecification. Display range is -95 to 999.9°F (-70 to 537.0°C).
Resolution 0.1°F (0.1°C)
Accuracy
(Shown accuracies are after field calibration)
±1.0°F: -95 to 200°F
±2.0°F: 200 to 999.9°F
±0.5°C: -70 to 93°C
±1.0°C: 93 to 5370°C
General Specifications
Display size 5" (diagonal)
Backlight Blue (adjustable duration)
Radio Frequency 2.4 GHz
Wireless Range 1000 feet (305 meters) line of sight
Distance decreases through obstructions
Data Port USB-C -For extracting logged data or updating firmware
Battery 6 x AA (Battery life below based on alkaline type)
Battery life 405 hours typical (without vacuum, backlight, and wireless)
Low battery indication Icon displayed when the battery voltage drops below the operating level
Auto Shut off 30 minutes of inactivity (adjustable)
Operating environment 14 to 122°F (-10 to 50°C) at <75% RH
Storage temperature -4 to 140°F (-20 to 60°C), 0 to 80% RH (with battery removed)
Temperature coefficient 0.1 x (specified accuracy) per 1.8°F (14 to 64°F, 82 to 122°F), per°C (-10 to 18°C, 28 to 50°C)
Over range OL for pressure
- - - - for temperature
Weight 3.31 lbs (1.5 kg)
Water Resistant Designed to IP55
Refrigerants R11 R115 R290 R407A R414A R422A R438A R458A R600 R12 R116 R401A R407C R414B R422B R448A R500 R600A R13 R123 R401B R407F R416A R422CR449A R501 R601 R22 R124 R402A R407H R417A R422D R450A R502 R601AR23 R125 R402B R408A R417C R424A R452A R503 R744*R32 R134A R403B R409A R420A R427A R452B R507A R1233ZD R113 R236FA R404A R410AR421A R428A R453A R508B R1234YF R114 R245FA R406A R413AR421B R434A R454B R513A R1234ZE
Click here for complete specifications on the Fieldpiece SM382V

What's included with the Fieldpiece SM382V

  • SM382V 3-Port Manifold
  • 2 x TC24 Wired Type-K Pipe Clamp Thermocouple
  • ATA1 Type-K Bead Thermocouple with Clip
  • ANC82 Easy-Open, Padded Case
  • 6 x AA Alkaline Batteries
  • Operator's Manual
  • One-Year Warranty

Click on a category to view a selection of compatible accessories with the Fieldpiece SM382V SMAN 3-Port Wireless Digital Refrigerant Manifold.

Fieldpiece TC24 Pipe Clamp Thermocouple, 3/8" to 1-3/8" TC24
TC24 is an accurate pipe clamp thermocouple to measure temperatures on pipes or any other cylindrical surface between 3/8 and 1-3/8. This pipe-clamp thermocouple is perfect for HVAC/R pipes that are fixed, at any angle, to walls or another surface in residential or light commercial cooling systems. The TC24 pipe clamp connects to any measuring device with a Type-K thermocouple jack.




Fieldpiece TC48 Large Pipe Clamp Type K Thermocouple for 3/4" to 4-1/8" Pipes TC48
TC48 Large Pipe Clamp Type K Thermocouple is a large jaw pipe clamp used to take the temperature of pipes or any electrically conductive cylindrical surface measuring between 3/4 to 4-1/8 in diameter. The TC48 pipe clamp thermometer comes with a 6' kink-free cable with a type K plug for universal use. This pipe clamp is ideal for residential, commercial, and refrigeration field service professionals who have struggled with getting an accurate reading on larger pipes.




Ask a question about Fieldpiece SM382V SMAN 3-Port Wireless Digital Refrigerant Manifold

Customer Reviews for the Fieldpiece SM382V

Fieldpiece SM382V Offers

The Fieldpiece SM382V digital manifold has been upgraded for ultimate field protection and long-range wireless communication. The Fieldpiece SM382V SMAN manifold includes a fully rubberized case that seals and protects it from dust, bumps, and light rain, and the heavy-duty hook allows you to hang it in your work vehicle or job site. The A/C specialist can view the calculated target superheat while monitoring, in real time, how their change is affecting actual superheat and subcooling. All measurements and live calculations such as pipe temperatures, refrigerant usage, and indoor air temperatures can be viewed on the extra-large 5” LCD screen or a mobile device up to 1000 feet (305 meters) when connected to the Job Link System App. In addition, when using the Job Link App, work can be documented, and reports generated from the smartphone or tablet.
The SMAN 382V includes over 70 refrigerants pre-programmed and a rolling list of the ten most recently used refrigerants stored at the top of the main refrigerant list for quick selection. The current refrigerant is automatically added to this list of ten refrigerants when the manifold powers off.
The Fieldpiece SM382V wireless manifold with micron gauge includes some customizable features, such as adjustable auto power-off duration, and the ability to adjust the backlight duration. In addition, a technician can set high and low vacuum alarms, and select each unit of measurement individually.
A Nitrogen Test (Tightness Test) is available to check for leaks after repairs or on new installs before charging with refrigerant. The timer tracks the duration of the test and temperature is compensated with SL temp to avoid false positives.
Add Job Link® System wireless tools to your arsenal and get live readings directly on the SMAN® manifold screen from the Job Link Psychrometers (JL3RH), Job Link Pipe Clamps (JL3PC), and SR47 Refrigerant Scale. Place pipe clamps in the perfect location, view live air measurements and calculations while making adjustments, and monitor and record refrigerant weight for precise recovery and charging documentation. Up to nine jobs can be saved to the internal flash drive.
The Fieldpiece SMAN 382 has an extremely durable impact-resistant case, reinforced hook, and hermetically sealed sight glass, and is water-resistant with an IP55 rating. In addition, the three protected thermocouple jacks have been moved to the back for additional protection. Note: Fieldpiece SM382V is a direct replacement of the popular Fieldpiece SMAN380V.

Features

  • Features an integrated vacuum gauge
  • Designed with low profile, lay-flat hose ports for added durability
  • Customizable auto power off, backlight duration
  • Customizable high and low vacuum alarms
  • Includes hermetically sealed sight glass to see refrigerant flow and condition
  • View wireless probe and scale readings
  • Logs up to 168 hours of data
  • Loaded with over 70 refrigerants, including A2Ls
  • Measurements can be viewed on a mobile device up to 1000 feet (305 meters) away
  • Runs a temperature-compensated nitrogen pressure test, with a timer
  • Protected thermocouple jacks for pipe and outdoor temps
  • Super rugged construction
  • Water-resistant (IP55)
  • Serves as a central data hub for Job Link® wireless tools and connects to the Job Link® System App
  • Monitor and record refrigerant weight

Simply Strong

  • The SM382V 2-valve Manifold is simply strong. The heavy-duty casing, reinforced hook, IP55 dust and water resistance, impact resistant screen, protected thermocouple jacks, and hermetically sealed sight glass, all ensure the SMANs are ready to go to work.

Packed with Knowledge

  • The SM382V is designed to work the way you do with advanced features to streamline your job and provide the answers you need.

Measures

  • Line pressures, pipe temperatures, dry bulb temperature, and system vacuum

Calculates

  • Superheat, subcooling, vapor saturation, liquid saturation, and delta T
  • Live target delta T and target evaporator exit temperature with optional Job Link wireless-tools
  • Temperature-compensated pressure differential for nitrogen pressure testing

Data Logs

  • Stores up to 9 jobs internally
  • Logs up to 168 continuous hours

Is Customizable

  • Select the measurements to display
  • Select wireless ON/OFF
  • Set high and low vacuum alarms

Applications

  • Commercial HVAC/R
  • Residential HVAC/R
  • Full System Analysis

Fieldpiece SM382V Specifications

Pressure
Sensor Type Absolute pressure sensors
Port Type (3) 1/4" standard SAE male flare fittings
Pressure Range and Units 870 Psig (English), 60.00 Bar (Metric), 6.000 MPa (Metric), and 6000 kPa (Metric)
Negative Pressure Range and Units 29 inHg (English), 74 cmHg (Metric), 0.98 Bar (Metric)
Resolution 0.1 Psig
0.01 Bar
0.001 MPa
1 kPa
0.1 inHg
1 cmHg
Negative Pressure Accuracy 29 inHg to 0 inHg: ±0.2 inHg
74 cmHg to 0 cmHg: ±1 cmHg0.98 Bar to 0 Bar
±0.01 Bar
Pressure Accuracy ±1 Psig: 0 to 200 Psig
±(0.3% of reading + 1 Psig): 200 to 870 Psig
±0.07 Bar: 0 to 13.78 Bar
±(0.3% of reading + 0.07 Bar): 13.78 to 60.00 Bar
±0.007 MPa: 0 to 1.378 MPa
±(0.3% of reading + 0.007 MPa): 1.378 to 6.000 MPa
±7 kPa: 0 to 1378 kPa
±(0.3% of reading + 7 kPa): 1378 to 6000 kPa
Maximum overload pressure 870 Psig (5998 kPa)
Units Psig, kPa, MPa, bar, inHg, and cmHg
Microns for Vacuum
Sensor Type Thermistor
Port Type 3 x 1/4" standard NPT male flare fittings
Range and Units 50 to 9999 microns of mercury (English)
6.7 to 1330 Pascals (Metric)
0.067 to 13.30 mBar (Metric)
50 to 9999 mTorr (Metric)
0.050 to 9.999 Torr (Metric, equivalent to mmHg)
Resolution 1 micron of mercury (below 2000 microns)
0.1 Pascal (below 250 Pascals)
0.001 mBar (below 2.500 mBar)
1 mTorr (below 2000 mTorr)
0.001 Torr (below 2.000 Torr)
Accuracy at 25°C (77°F) ±(5% of reading + 5 microns of mercury): 50 to 2000 microns
±(5% of reading + 1.0 Pascal): 6.7 to 266.0 Pascal
±(5% of reading + 0.010 mBar): 0.067 to 2.660 mBar
±(5% of reading + 5 mTorr): 50 to 2000 mTorr
±(5% of reading + 0.005 Torr): 0.067 to 2.000 Tor
Maximum Overload pressure 580 psig
Units Microns of mercury
Temperature
Sensor type Type K thermocouple(nickel chromium/nickel aluminum)
Jack Type (3) Type K thermocouple
Range -50 to 257°F (-46 to 125°C), limited by the thermocouplespecification. Display range is -95 to 999.9°F (-70 to 537.0°C).
Resolution 0.1°F (0.1°C)
Accuracy
(Shown accuracies are after field calibration)
±1.0°F: -95 to 200°F
±2.0°F: 200 to 999.9°F
±0.5°C: -70 to 93°C
±1.0°C: 93 to 5370°C
General Specifications
Display size 5" (diagonal)
Backlight Blue (adjustable duration)
Radio Frequency 2.4 GHz
Wireless Range 1000 feet (305 meters) line of sight
Distance decreases through obstructions
Data Port USB-C -For extracting logged data or updating firmware
Battery 6 x AA (Battery life below based on alkaline type)
Battery life 405 hours typical (without vacuum, backlight, and wireless)
Low battery indication Icon displayed when the battery voltage drops below the operating level
Auto Shut off 30 minutes of inactivity (adjustable)
Operating environment 14 to 122°F (-10 to 50°C) at <75% RH
Storage temperature -4 to 140°F (-20 to 60°C), 0 to 80% RH (with battery removed)
Temperature coefficient 0.1 x (specified accuracy) per 1.8°F (14 to 64°F, 82 to 122°F), per°C (-10 to 18°C, 28 to 50°C)
Over range OL for pressure
- - - - for temperature
Weight 3.31 lbs (1.5 kg)
Water Resistant Designed to IP55
Refrigerants R11 R115 R290 R407A R414A R422A R438A R458A R600 R12 R116 R401A R407C R414B R422B R448A R500 R600A R13 R123 R401B R407F R416A R422CR449A R501 R601 R22 R124 R402A R407H R417A R422D R450A R502 R601AR23 R125 R402B R408A R417C R424A R452A R503 R744*R32 R134A R403B R409A R420A R427A R452B R507A R1233ZD R113 R236FA R404A R410AR421A R428A R453A R508B R1234YF R114 R245FA R406A R413AR421B R434A R454B R513A R1234ZE
Click here for complete specifications on the Fieldpiece SM382V

What's included with the Fieldpiece SM382V

  • SM382V 3-Port Manifold
  • 2 x TC24 Wired Type-K Pipe Clamp Thermocouple
  • ATA1 Type-K Bead Thermocouple with Clip
  • ANC82 Easy-Open, Padded Case
  • 6 x AA Alkaline Batteries
  • Operator's Manual
  • One-Year Warranty

Click on a category to view a selection of compatible accessories with the Fieldpiece SM382V SMAN 3-Port Wireless Digital Refrigerant Manifold.

Fieldpiece TC24 Pipe Clamp Thermocouple, 3/8" to 1-3/8" TC24
TC24 is an accurate pipe clamp thermocouple to measure temperatures on pipes or any other cylindrical surface between 3/8 and 1-3/8. This pipe-clamp thermocouple is perfect for HVAC/R pipes that are fixed, at any angle, to walls or another surface in residential or light commercial cooling systems. The TC24 pipe clamp connects to any measuring device with a Type-K thermocouple jack.




Fieldpiece TC48 Large Pipe Clamp Type K Thermocouple for 3/4" to 4-1/8" Pipes TC48
TC48 Large Pipe Clamp Type K Thermocouple is a large jaw pipe clamp used to take the temperature of pipes or any electrically conductive cylindrical surface measuring between 3/4 to 4-1/8 in diameter. The TC48 pipe clamp thermometer comes with a 6' kink-free cable with a type K plug for universal use. This pipe clamp is ideal for residential, commercial, and refrigeration field service professionals who have struggled with getting an accurate reading on larger pipes.




Ask a question about Fieldpiece SM382V SMAN 3-Port Wireless Digital Refrigerant Manifold

Customer Reviews for the Fieldpiece SM382V

More Fieldpiece Products