Measures the height of liquid above the position in the tank referenced to atmospheric pressure.
The transmitter consists of a piezoresistive sensing element, encased in a 316 SS housing.
Bullet nose design protects the diaphragm from damage.
Incorporates lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty).
Comes equipped with a 270-pound tensile strength shielded and vented cable.
Ventilation tube in the cable automatically compensates for changes in atmospheric pressure above the tank.
The vent is protected with a maintenance free filter eliminating particulate or water droplets from entering the transducer.
Compensated Temperature Range: 0 to 140°F (-18 to 60°C)
Thermal Effect: ±0.02% full scale/°F.
Pressure Limit: 2X full scale.
Power Requirement: 13 to 30 VDC
Output Signal: 4 to 20 mA DC, 2-wire.
Response Time: 50 ms.
Max. Loop Resistance: 900 ohms at 30 VDC.
Electrical Connections: Wire pigtail.
Mounting Orientation: Suspended in tank below level being measured.
Weight: 2.2 lb (1.0 kg).
Electrical Protection: Lightning and surge protection.
Agency Approvals: None.
Features
Maintenance free vent filter
Slim design for tight applications
Measures the height of liquid above the position in the tank referenced to atmospheric pressure
The transmitter consists of a piezoresistive sensing element, encased in a 316 SS housing
Bullet nose design protects the diaphragm from damage
Incorporates lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty)
Comes equipped with a 270-pound tensile strength shielded and vented cable
Ventilation tube in the cable automatically compensates for changes in atmospheric pressure above the tank
The vent is protected with a maintenance free filter eliminating particulate or water droplets from entering the transducer
Measures the height of liquid above the position in the tank referenced to atmospheric pressure.
The transmitter consists of a piezoresistive sensing element, encased in a 316 SS housing.
Bullet nose design protects the diaphragm from damage.
Incorporates lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty).
Comes equipped with a 270-pound tensile strength shielded and vented cable.
Ventilation tube in the cable automatically compensates for changes in atmospheric pressure above the tank.
The vent is protected with a maintenance free filter eliminating particulate or water droplets from entering the transducer.
Compensated Temperature Range: 0 to 140°F (-18 to 60°C)
Thermal Effect: ±0.02% full scale/°F.
Pressure Limit: 2X full scale.
Power Requirement: 13 to 30 VDC
Output Signal: 4 to 20 mA DC, 2-wire.
Response Time: 50 ms.
Max. Loop Resistance: 900 ohms at 30 VDC.
Electrical Connections: Wire pigtail.
Mounting Orientation: Suspended in tank below level being measured.
Weight: 2.2 lb (1.0 kg).
Electrical Protection: Lightning and surge protection.
Agency Approvals: None.
Features
Maintenance free vent filter
Slim design for tight applications
Measures the height of liquid above the position in the tank referenced to atmospheric pressure
The transmitter consists of a piezoresistive sensing element, encased in a 316 SS housing
Bullet nose design protects the diaphragm from damage
Incorporates lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty)
Comes equipped with a 270-pound tensile strength shielded and vented cable
Ventilation tube in the cable automatically compensates for changes in atmospheric pressure above the tank
The vent is protected with a maintenance free filter eliminating particulate or water droplets from entering the transducer
Our website gives you access to the best pricing we can offer. We encourage you to use our Build a Quote tool to build yourself a quote with the item(s) you’re interested in.
Your quote will then be emailed to you with all of the information you require. This also locks in your pricing for 30 days!
Check your Order Status
Check the status of your online order by entering your information below. Verify your order information is correct and the email address is what was used when you placed your order.
Ask our experts
To ask our Dwyer experts a question please include your contact details. * Required Fields
Email Me When Available
Receive updates on when this product will be available for ordering.
*We don’t share your email. You can unsubscribe at any time.
Be the first to know!
Be the first to know when we have news, discounts, special offers and promotions.
*We don’t share your email. You can unsubscribe at any time.
Be the first to receive updates!
The Energy Monitoring System You've Been Waiting For!
Launching 2022
*We don’t share your email. You can unsubscribe at any time.
Exclusive Member Store
Don’t have a Member Account? Our Member Store gives you access to the following advantages:
Exclusive Member Pricing*
Exclusive Special Offers
Free Shipping on Online Orders over $199
Express Checkouts
Access to an additional 200 000+ Products via our Extended Search tool
Multiple Shipping Addresses
Additional Shipping Options
*Where applicable. Some of our pricing is already discounted.