Dwyer 616D-2 Differential Pressure Transmitter (0-6"w.c.)

Model: 616D-2

Dwyer 616D-2 Differential Pressure Transmitter (0-6"w.c.)

Model: 616D-2

Senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. Specifically designed to mount on a 35 mm DIN rail in a panel.

Senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. Specifically designed to mount on a 35 mm DIN rail in a panel.

Sale Price $362.70 CAD
Regular Price $390.00 CAD
Availability 2 to 3 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your Dwyer 616D-2 Differential Pressure Transmitter (0-6"w.c.)

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your Dwyer 616D-2 Differential Pressure Transmitter (0-6"w.c.)

Dwyer 616D-2 Offers

  • Mounting style allows for several units to be mounted closely together reducing required space.
  • A wide range of models are available factory calibrated to specific ranges.
  • The span and zero controls are for use when checking calibration.
    They are not intended for re-ranging to a significantly different span.
  • Versatile circuit design enables operation in 2-wire current loops.

Specifications:

Service: Air and non-combustible, compatible gases.

Wetted Materials: Consult factory.

Accuracy: ±0.25% F.S.

at 70°F.

Stability: ±1% F.S./yr.

Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).

Pressure Limits: 5 psig.

Thermal Effect: ±0.02% F.S./°F (0.0012% F.S./°C).

Power Requirements: 10-35 VDC (2-wire).

Output Signal: 4 to 20 mA.

Zero and Span Adjustments: Potentiometers for zero and span.

Loop Resistance: DC: 0-1250 ohms maximum.

Current Consumption: DC: 38 mA maximum.

Electrical Connections: Screw-type terminal block.

Process Connections: 1/8" female NPT.

Accessories included are two barbed fittings for 1/8" (3.12 mm) and 3/16" (4.77 mm) I.D.

rubber or vinyl tubing.

Mounting Orientation: Vertical, on a 1.378" (35 mm) DIN rail.

Weight: 4.8 oz (136 g).

Features

  • Simple calibration push-buttons to set zero and span
  • Cost effective and compact device suitable for OEM applications where space, simplicity, and value are key

Applications

  • Air handlers
  • Duct pressure
  • Variable air volume
  • Filter monitoring

Dwyer 616D-2 Specifications

Service Air and non-combustible, compatible gases
Accuracy ±0.25 FS at 77°F (25°C)
Thermal Effect ±0.02% FS/°F (0.036% FS/°C)
Stability ±1% FS/yr
Temperature Limits 14 to 185°F (-10 to 85°C)
Power Requirements 10 to 35 VDC (2-wire)
17 to 36 VDC, or isolated 21.6 to 33 VAC (3-wire)
Output Signal 4 to 20 mA (2-wire); 0 to 10 VDC (3-wire)
Zero and Span Adjustments Push buttons
Loop Resistance Current output: 0 to 1250 Ω max
Voltage output: Load resistance 1 kΩ min
Current Consumption 40 mA max
Electrical Connections Screw-type terminal block
Process Connections ⅛" female NPT
Mounting Orientation Vertical, on a 1.378" (35 mm) DIN rail
Weight 4.8 oz (136 g)
Agency Approvals CE
Click here for complete specifications on the Dwyer 616D-2

What's included with the Dwyer 616D-2

  • Dwyer 616D-2 Differential Pressure Transmitter (0-6"w.c.)

Ask a question about Dwyer 616D-2 Differential Pressure Transmitter (0-6"w.c.)

Customer Reviews for the Dwyer 616D-2

Dwyer 616D-2 Offers

  • Mounting style allows for several units to be mounted closely together reducing required space.
  • A wide range of models are available factory calibrated to specific ranges.
  • The span and zero controls are for use when checking calibration.
    They are not intended for re-ranging to a significantly different span.
  • Versatile circuit design enables operation in 2-wire current loops.

Specifications:

Service: Air and non-combustible, compatible gases.

Wetted Materials: Consult factory.

Accuracy: ±0.25% F.S.

at 70°F.

Stability: ±1% F.S./yr.

Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).

Pressure Limits: 5 psig.

Thermal Effect: ±0.02% F.S./°F (0.0012% F.S./°C).

Power Requirements: 10-35 VDC (2-wire).

Output Signal: 4 to 20 mA.

Zero and Span Adjustments: Potentiometers for zero and span.

Loop Resistance: DC: 0-1250 ohms maximum.

Current Consumption: DC: 38 mA maximum.

Electrical Connections: Screw-type terminal block.

Process Connections: 1/8" female NPT.

Accessories included are two barbed fittings for 1/8" (3.12 mm) and 3/16" (4.77 mm) I.D.

rubber or vinyl tubing.

Mounting Orientation: Vertical, on a 1.378" (35 mm) DIN rail.

Weight: 4.8 oz (136 g).

Features

  • Simple calibration push-buttons to set zero and span
  • Cost effective and compact device suitable for OEM applications where space, simplicity, and value are key

Applications

  • Air handlers
  • Duct pressure
  • Variable air volume
  • Filter monitoring

Dwyer 616D-2 Specifications

Service Air and non-combustible, compatible gases
Accuracy ±0.25 FS at 77°F (25°C)
Thermal Effect ±0.02% FS/°F (0.036% FS/°C)
Stability ±1% FS/yr
Temperature Limits 14 to 185°F (-10 to 85°C)
Power Requirements 10 to 35 VDC (2-wire)
17 to 36 VDC, or isolated 21.6 to 33 VAC (3-wire)
Output Signal 4 to 20 mA (2-wire); 0 to 10 VDC (3-wire)
Zero and Span Adjustments Push buttons
Loop Resistance Current output: 0 to 1250 Ω max
Voltage output: Load resistance 1 kΩ min
Current Consumption 40 mA max
Electrical Connections Screw-type terminal block
Process Connections ⅛" female NPT
Mounting Orientation Vertical, on a 1.378" (35 mm) DIN rail
Weight 4.8 oz (136 g)
Agency Approvals CE
Click here for complete specifications on the Dwyer 616D-2

What's included with the Dwyer 616D-2

  • Dwyer 616D-2 Differential Pressure Transmitter (0-6"w.c.)

Ask a question about Dwyer 616D-2 Differential Pressure Transmitter (0-6"w.c.)

Customer Reviews for the Dwyer 616D-2

More Dwyer Products