The ELITEPRO XC is the leading portable three phase RMS recording power meter for building or equipment electrical load studies and power usage analysis. With USB/Ethernet communications, includes crocodile clips. Please note that all DENT software is compatible with Windows 7 and newer operating systems. It is not compatible with macOS.
Our rentals come fully calibrated to traceable standards. Have your own instrument? We also offer calibration services for this model (CERTIWM3).
The ELITEPRO XC is the leading portable three phase RMS recording power meter for building or equipment electrical load studies and power usage analysis. With USB/Ethernet communications, includes crocodile clips. Please note that all DENT software is compatible with Windows 7 and newer operating systems. It is not compatible with macOS.
Our rentals come fully calibrated to traceable standards. Have your own instrument? We also offer calibration services for this model (CERTIWM3).
The Dent ELITEpro XC Energy Datalogger is ideal for the measurement and analysis of energy consumption data, gathered from analog voltage and current inputs. This model includes a set of crocodile clips and a case, and is designed for international use. The ELITEpro XC features configurable analog inputs with a voltage transducer range of 0 to 10VDC and a current loop transducer range of 0 or 4 to 20mA. This datalogger may be used on single or three-phase systems, using phase-to-phase services of a range of 80 to 600V (AC or DC) when line powered and 0 to 600V (AC or DC) when externally powered.
The ELITEpro XC is easy to use, with a simple setup and DENT's patended PhaseChek indicator to ensure proper instillation. This datalogger communicated quickly via USB connection and features a standard Ethernet port. Its compact, durable design means the ELITEpro XC can fit easily inside of breaker panels-making it the ideal datalogger for energy audits, surveys, and load profiling.
Step-by-Step: Connect to a Remote ELITEpro XC Using Port Forwarding
If your ELITEpro XC is on a local area network at a remote project site, but you're hundreds of miles away, at your office, and need to download data off the meter? Port Forwarding makes it possible to complete the download.
What Happens to the ELITEpro XC During a Power Outage
Learn how to use a handy ELOG feature, called Fill Missing Records, to help correct data downloaded from a logger that has experienced a power outage.
Technical | |
Service Type | Single phase (two wire or three wire), three phase-four wire (WYE), three phase-three wire (Delta), DC systems (solar/battery) |
Voltage Channels | 3 channels, CAT III, 0 to 600 V AC (line-to-line) or 600 VDC |
Current Channels | 4 channels, 0.67 V AC max, +/- 1 V DC Ideal for 333 mV full scale CTs |
Maximum Current Input | External transducer dependent 200% of current transducer rating (mV CTs) Measure up to 6000 A with RoCoil CTs. |
Measurement Type | True RMS using high-speed digital signal processing (DSP) |
Line Frequency | DC/50/60/400 Hz* Performance varies at 400 Hz operation. Contact the factory for details. |
Waveform Sampling | 12 kHz |
Channel Sampling Rate | 0.125 seconds |
Integration Period | 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day |
Energy Measurements | Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and system total |
Analog Measurements | 0 to 10 V, 0 or 4 to 20 mA current loop Non-isolated, external power for current loop. User scaling for sensor reporting in physical units |
Accuracy | Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog |
Resolution | 0.01 A, 0.1 V, 1 W, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA |
LED Indicators | Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™). |
Power | |
Line-Power | From L1 Phase to L2 Phase. 80 to 600 V (AC or DC) CAT III DC/50/60/400 Hz, 125 mA, 5 W, or 10 VA max Non-user replaceable 0.5 A internal fuse protection. |
Power In | 6 to 10 VDC, 500 mA |
Power Out | 6 VDC, 200 mA max |
Communications | |
USB (Standard) | USB standard (type B) 6' (1.8 m) A-to-B USB cable (included) |
Ethernet (Standard) | Standard RJ-45 connector supports 10/100 MB Ethernet over Cat 5 or better Configure for DHCP or static IP |
Bluetooth Wireless Technology (Optional) | Internal antenna with 10 to 100' range (typical) Requires Bluetooth® wireless technology adapter on Windows PC Adapter must support the Serial Port Profile (SPP). |
Wi-Fi Adapter† (optional) | Wi-Fi option available as two separate configurations: • Internal antenna: typical range 75 to 300' • External 3 dbi antenna: typical range 150 to 300' ELITEpro XC loggers that are equipped with a Wi-Fi package contain an internal antenna. An external antenna is optional. You may toggle between using the internal and external antenna (if it is available on your logger) by checking or unchecking the Use External Antenna checkbox in ELOG. US/NORTH AMERICAN ELITEpro XC configuration includes 4 color (black, blue, red, white) voltage leads and croc clips. INTERNATIONAL ELITEpro XC configuration includes 3 black voltage lead connections, 1 white connection (neutral) and 5 color (black, blue, red, white, yellow) voltage leads and croc clips. |
Mechanical | |
Operating Temperature | 20 to 140°F (-7 to 60°C) |
Operating Humidity | 5 to 95% non-condensing |
Enclosure Type | ABS plastic, 94-V0 flammability rating |
Dimensions | 8.5 x 2.5 x 1.9" (21.6 x 6.3 x 4.7 cm) |
Weight | 12 ounces (340 g) |
This rental includes:
Click on a category to view a selection of compatible accessories with the Rental - Dent ElitePro EXC-I-N-C XC Portable Recording Power Meter with 3 CT-R16-A4-U RoCoil Flexible CTs.
Technical | |
Service Type | Single phase (two wire or three wire), three phase-four wire (WYE), three phase-three wire (Delta), DC systems (solar/battery) |
Voltage Channels | 3 channels, CAT III, 0 to 600 V AC (line-to-line) or 600 VDC |
Current Channels | 4 channels, 0.67 V AC max, +/- 1 V DC Ideal for 333 mV full scale CTs |
Maximum Current Input | External transducer dependent 200% of current transducer rating (mV CTs) Measure up to 6000 A with RoCoil CTs. |
Measurement Type | True RMS using high-speed digital signal processing (DSP) |
Line Frequency | DC/50/60/400 Hz* Performance varies at 400 Hz operation. Contact the factory for details. |
Waveform Sampling | 12 kHz |
Channel Sampling Rate | 0.125 seconds |
Integration Period | 1, 3, 15, 30 seconds; 1, 2, 5, 10, 15, 20, and 30 minutes; 1 and 12 hours, 1 day |
Energy Measurements | Volts, Amps, Amp-Hrs (Ah), kW, kWh, kVAR, kVARh, kVA, kVAh, Displacement Power Factor (dPF). All parameters for each phase and system total |
Analog Measurements | 0 to 10 V, 0 or 4 to 20 mA current loop Non-isolated, external power for current loop. User scaling for sensor reporting in physical units |
Accuracy | Better than 1% (<0.2% typical) for V, A, kW, kVAR, kVA, PF, Analog |
Resolution | 0.01 A, 0.1 V, 1 W, 1 VAR, 1 VA, 0.01 PF, 0.01 ANA |
LED Indicators | Tri-color (red, green, blue): 1 LED indicates communication (blue for wireless, Bluetooth® or Ethernet), 4 LEDs for correct phasing (PhaseChek™). |
Power | |
Line-Power | From L1 Phase to L2 Phase. 80 to 600 V (AC or DC) CAT III DC/50/60/400 Hz, 125 mA, 5 W, or 10 VA max Non-user replaceable 0.5 A internal fuse protection. |
Power In | 6 to 10 VDC, 500 mA |
Power Out | 6 VDC, 200 mA max |
Communications | |
USB (Standard) | USB standard (type B) 6' (1.8 m) A-to-B USB cable (included) |
Ethernet (Standard) | Standard RJ-45 connector supports 10/100 MB Ethernet over Cat 5 or better Configure for DHCP or static IP |
Bluetooth Wireless Technology (Optional) | Internal antenna with 10 to 100' range (typical) Requires Bluetooth® wireless technology adapter on Windows PC Adapter must support the Serial Port Profile (SPP). |
Wi-Fi Adapter† (optional) | Wi-Fi option available as two separate configurations: • Internal antenna: typical range 75 to 300' • External 3 dbi antenna: typical range 150 to 300' ELITEpro XC loggers that are equipped with a Wi-Fi package contain an internal antenna. An external antenna is optional. You may toggle between using the internal and external antenna (if it is available on your logger) by checking or unchecking the Use External Antenna checkbox in ELOG. US/NORTH AMERICAN ELITEpro XC configuration includes 4 color (black, blue, red, white) voltage leads and croc clips. INTERNATIONAL ELITEpro XC configuration includes 3 black voltage lead connections, 1 white connection (neutral) and 5 color (black, blue, red, white, yellow) voltage leads and croc clips. |
Mechanical | |
Operating Temperature | 20 to 140°F (-7 to 60°C) |
Operating Humidity | 5 to 95% non-condensing |
Enclosure Type | ABS plastic, 94-V0 flammability rating |
Dimensions | 8.5 x 2.5 x 1.9" (21.6 x 6.3 x 4.7 cm) |
Weight | 12 ounces (340 g) |
This rental includes:
Click on a category to view a selection of compatible accessories with the Rental - Dent ElitePro EXC-I-N-C XC Portable Recording Power Meter with 3 CT-R16-A4-U RoCoil Flexible CTs.