Measure and display differential, and high/low side pressures without changing the hose connections or valve settings with this hydronic manometer featuring a backlight display. Additionally, this manometer is ideal for balancing hydronic heating and cooling systems, checking pump performance, and setting balancing valves.
Measure and display differential, and high/low side pressures without changing the hose connections or valve settings with this hydronic manometer featuring a backlight display. Additionally, this manometer is ideal for balancing hydronic heating and cooling systems, checking pump performance, and setting balancing valves.
Features
Applications
Pressure | Differential range: -300 to 300 psi (-2,068 to 2,068 kPa) Gauge range: -20 to 300 psi (-138 to 2,068 kPa), (-40 to 610 in. Hg) Resolution (best): 0.001 psi (0.01 kPa), (0.01 in. Hg) Accuracy: ±1% of reading plus .072 psi, (0.5 kPa) (0.15 in. Hg) Units: psi, in. H2O, ft H2O, kPa, mm Hg, in. Hg, m H2O, bar Pressure connection: ¼" 37° flare fitting, Male |
Temperature | Operating (electronics): 40 to 113°F (5 to 45°C) Storage: -4 to 140°F (-20 to 60°C) Liquid Media: 32 to 180°F (0 to 82°C) Probe (immersion): -40 to 250°F (-40 to 121 °C) Resolution: 0.1°F (0.1°C) Accuracy: ±0.5% of reading +1.2°F (0.7°C) Units: °F, °C |
Time Constant | User selectable (1, 5, 10, 20, and 30 seconds) |
Power | Four AA-size cells, or AC adapter |
Dimensions | 11.1 x 4.7 x 3.5" (28.2 x 11.9 x 8.8 cm) |
Weight | 2.65 lbs (1.20 kg) with batteries |
Click on a category to view a selection of compatible accessories with the TSI/Alnor HM675 Hydronic Manometer with probes, ±300 psi, -20 to 300 psi.
Pressure | Differential range: -300 to 300 psi (-2,068 to 2,068 kPa) Gauge range: -20 to 300 psi (-138 to 2,068 kPa), (-40 to 610 in. Hg) Resolution (best): 0.001 psi (0.01 kPa), (0.01 in. Hg) Accuracy: ±1% of reading plus .072 psi, (0.5 kPa) (0.15 in. Hg) Units: psi, in. H2O, ft H2O, kPa, mm Hg, in. Hg, m H2O, bar Pressure connection: ¼" 37° flare fitting, Male |
Temperature | Operating (electronics): 40 to 113°F (5 to 45°C) Storage: -4 to 140°F (-20 to 60°C) Liquid Media: 32 to 180°F (0 to 82°C) Probe (immersion): -40 to 250°F (-40 to 121 °C) Resolution: 0.1°F (0.1°C) Accuracy: ±0.5% of reading +1.2°F (0.7°C) Units: °F, °C |
Time Constant | User selectable (1, 5, 10, 20, and 30 seconds) |
Power | Four AA-size cells, or AC adapter |
Dimensions | 11.1 x 4.7 x 3.5" (28.2 x 11.9 x 8.8 cm) |
Weight | 2.65 lbs (1.20 kg) with batteries |
Click on a category to view a selection of compatible accessories with the TSI/Alnor HM675 Hydronic Manometer with probes, ±300 psi, -20 to 300 psi.