The PEL 113 is a cost-effective, easy-to-use power and energy data logger designed to simplify energy audits, system monitoring, and electrical upgrades. Delivering precise, real-time measurements for single-phase, split-phase, and three-phase electrical systems, it helps efficiency professionals, facility managers, and electrical engineers reduce costs, improve power quality, and optimize system performance.
The PEL 113 is a cost-effective, easy-to-use power and energy data logger designed to simplify energy audits, system monitoring, and electrical upgrades. Delivering precise, real-time measurements for single-phase, split-phase, and three-phase electrical systems, it helps efficiency professionals, facility managers, and electrical engineers reduce costs, improve power quality, and optimize system performance.
With long-term recording capabilities, seamless installation, multiple connectivity options, built-in alarms and reporting, and advanced DataView® software, the PEL 113 provides accurate, actionable data for smarter energy management. Its compact, magnetic design makes it easy to mount in most electrical panels, making it a powerful solution for a wide range of applications.
Features
Applications
User-Friendly Design
Comprehensive Power Measurements
Advanced Analysis Features
DataView® Software
The DataView® software simplifies setup, monitoring, and analysis:
Flexible Network Connectivity
| General Specifications | |
| Number of Voltage Inputs | 3 (V1, V2, V3) |
| Number of Current Inputs | 3 (L1, L2, L3) |
| Distribution Systems | Single-/Split-/3-phase, DC, etc. (17 choices) |
| Measurements | |
| Voltage Range - Phase-Neutral (V) | (10 to 1000) V AC/DC 2 |
| Voltage Range - Phase-Phase (U) | (10 to 1000) V AC 2 |
| Typical Accuracy - Voltage | ± 0.2% R ± 0.2 V |
| Current Range AC | 200 mA to 12 kAAC |
| Current Range DC | 50 mA to 1300 ADC 3 |
| Typical Accuracy - Current -(Meter Only) 4 | ± 0.4 % R ± 0.04 % Inom |
| Network Frequencies | DC/50/60/400 Hz (VFD/PWM not available) |
| Calculated Measurements | |
| Voltage Ratios | up to 650 kV |
| Current Ratios | Not available with AmpFlex®/MiniFlex® sensors |
| Power (P, P+ , Punb, Qf, N, D, S) | up to 10 GW/Gvar/GVA 5 |
| Energy | up to 4 EWh/EVAh/Evarh 5 |
| Phase | cos φ, tan Φ, PF |
| Phase Order / Phasor Diagram | Yes / Yes (with DataView® or App for Android) |
| Harmonics | THD for V, A and harmonics to 50th order for V, A |
| Recording | |
| Aggregations (Fixed) | 200 ms/1 s trends |
| Aggregations (Selectable) | (1 to 60) min (12 choices) |
| Min/Max Values | Yes |
| Alarms | Up to 32 separate alarms |
| Emailed Reports | Yes, Alarms and Periodical Min/Max data through DataViewSync® |
| Storage Media | SD Card (32 GB Max) |
| Recording Length | Several weeks to years (Configuration dependent) |
| Other Features | |
| Communication | USB, Ethernet/Wi-Fi LAN, Ethernet/Wi-Fi Direct, DataViewSync® |
| Software | DataView® included, free App for Android™ |
| NEC Article 220.87 - Load Study Compliant | Yes, DataView® configuration button and report templates |
| Mounting | Embedded magnets in case |
| Powered from phase voltage | Phase Power Adapter (Cat. #2137.90) |
| External Power Supply | 120 / 240 V Line Power Cord |
| Safety and Mechanical | |
| Electrical Safety | 600 V CAT IV / 1000 V CAT III |
| Ingress Protection | IP 54 / IP 20 |
| Weight | < 2.2 lbs (1 kg) |
Click on a category to view a selection of compatible accessories with the AEMC PEL 113 Power and Energy Logger with BK sensors.
| General Specifications | |
| Number of Voltage Inputs | 3 (V1, V2, V3) |
| Number of Current Inputs | 3 (L1, L2, L3) |
| Distribution Systems | Single-/Split-/3-phase, DC, etc. (17 choices) |
| Measurements | |
| Voltage Range - Phase-Neutral (V) | (10 to 1000) V AC/DC 2 |
| Voltage Range - Phase-Phase (U) | (10 to 1000) V AC 2 |
| Typical Accuracy - Voltage | ± 0.2% R ± 0.2 V |
| Current Range AC | 200 mA to 12 kAAC |
| Current Range DC | 50 mA to 1300 ADC 3 |
| Typical Accuracy - Current -(Meter Only) 4 | ± 0.4 % R ± 0.04 % Inom |
| Network Frequencies | DC/50/60/400 Hz (VFD/PWM not available) |
| Calculated Measurements | |
| Voltage Ratios | up to 650 kV |
| Current Ratios | Not available with AmpFlex®/MiniFlex® sensors |
| Power (P, P+ , Punb, Qf, N, D, S) | up to 10 GW/Gvar/GVA 5 |
| Energy | up to 4 EWh/EVAh/Evarh 5 |
| Phase | cos φ, tan Φ, PF |
| Phase Order / Phasor Diagram | Yes / Yes (with DataView® or App for Android) |
| Harmonics | THD for V, A and harmonics to 50th order for V, A |
| Recording | |
| Aggregations (Fixed) | 200 ms/1 s trends |
| Aggregations (Selectable) | (1 to 60) min (12 choices) |
| Min/Max Values | Yes |
| Alarms | Up to 32 separate alarms |
| Emailed Reports | Yes, Alarms and Periodical Min/Max data through DataViewSync® |
| Storage Media | SD Card (32 GB Max) |
| Recording Length | Several weeks to years (Configuration dependent) |
| Other Features | |
| Communication | USB, Ethernet/Wi-Fi LAN, Ethernet/Wi-Fi Direct, DataViewSync® |
| Software | DataView® included, free App for Android™ |
| NEC Article 220.87 - Load Study Compliant | Yes, DataView® configuration button and report templates |
| Mounting | Embedded magnets in case |
| Powered from phase voltage | Phase Power Adapter (Cat. #2137.90) |
| External Power Supply | 120 / 240 V Line Power Cord |
| Safety and Mechanical | |
| Electrical Safety | 600 V CAT IV / 1000 V CAT III |
| Ingress Protection | IP 54 / IP 20 |
| Weight | < 2.2 lbs (1 kg) |
Click on a category to view a selection of compatible accessories with the AEMC PEL 113 Power and Energy Logger with BK sensors.