AEMC MN379 AC Current Probe, Lead, 5A/100A

Model: MN379 | Order No: 2153.01 | UPC: 685338030426

AEMC MN379 AC Current Probe, Lead, 5A/100A

Model: MN379 | Order No: 2153.01 | UPC: 685338030426

Features a measurement range up to 120Arms, a range and resolution capable of displaying 10mV of output per amp of measured current, a voltmeter accuracy of 0.5% or better to take full advantage of the accuracy of the probe and an input impedance of 1MΩ.

Features a measurement range up to 120Arms, a range and resolution capable of displaying 10mV of output per amp of measured current, a voltmeter accuracy of 0.5% or better to take full advantage of the accuracy of the probe and an input impedance of 1MΩ.

Sale Price $419.19 CAD
Regular Price $471.00 CAD
Availability 1 to 2 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 2153.01 AC Current Probe

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 2153.01 AC Current Probe

AEMC MN379 Offers

Designed to meet the most stringent demands in industry and electrical contracting, it also meets the latest safety and performance standards.

The Model MN379 has a 0.78" (20mm) jaw opening and will accommodate conductors up to 250kcmil. The unique hooked jaw design facilitates clamping and hooking into conductors. Polycarbonate materials and ultrasonic welding are used throughout to ensure ruggedness and overall lasting reliability.

Features

  • Small, compact size
  • Large jaw opening accommodated conductors up to 250kcmil
  • Designed for DMMs, loggers, recorders and oscilloscopes
  • Conforms to EN 61010, 600V CAT III

Applications

  • Measuring in breaker panels
  • Industrial loads
  • HVAC/R
  • Residential and commercial sites
  • 5A secondary current transformers (CTs) monitoring

AEMC MN379 Specifications

Nominal Range 5A, 100A
Measurement Range 5A: 0.005 to 6A; 100A: 0.1 to 120A
Transformation Ratio Voltage output
Output Signal 5A: 200mV/A
100A: 10mV/A
Frequency Range 40 to 10kHz
Limit Operating Conditions 200A MAX to 1kHz
Derating above 1kHz: 200A x (1*F), F in kHz
Working Voltage 600Vrms
Common Mode Voltage 600Vrms
Influence of Adjacent Conductor < 15mA/A at 50Hz
Influence of DC on AC signal 5A Range: DC Current < 1A, < 3%
100A Range: DC Current < 10A, < 10%
Influence of Conductor Position in Jaw 0.5% of mV output at 50/60Hz
Influence of Frequency 5A Range: 40Hz to 1kHz: <0.7% of mV output; 1kHz to 3kHz: <2%% of mV output
150A Range: 40Hz to 1kHz: <0.7% of mV output; 1kHz to 3kHz: <0.7% of mV output
Influence of Temperature ≤200 ppm/°K, or 0.2% of mV output per 10°K
Influence of Humidity (10 to 90% RH) ≤0.2% of mV output per 10°K at 18° to 28°C 
Click here for complete specifications on the AEMC Instruments MN379

What's included with the AEMC Instruments MN379

  • AEMC MN379 AC Current Probe, Lead, 5A/100A

Ask a question about AEMC MN379 AC Current Probe, Lead, 5A/100A

Customer Reviews for the AEMC Instruments MN379

AEMC MN379 Offers

Designed to meet the most stringent demands in industry and electrical contracting, it also meets the latest safety and performance standards.

The Model MN379 has a 0.78" (20mm) jaw opening and will accommodate conductors up to 250kcmil. The unique hooked jaw design facilitates clamping and hooking into conductors. Polycarbonate materials and ultrasonic welding are used throughout to ensure ruggedness and overall lasting reliability.

Features

  • Small, compact size
  • Large jaw opening accommodated conductors up to 250kcmil
  • Designed for DMMs, loggers, recorders and oscilloscopes
  • Conforms to EN 61010, 600V CAT III

Applications

  • Measuring in breaker panels
  • Industrial loads
  • HVAC/R
  • Residential and commercial sites
  • 5A secondary current transformers (CTs) monitoring

AEMC MN379 Specifications

Nominal Range 5A, 100A
Measurement Range 5A: 0.005 to 6A; 100A: 0.1 to 120A
Transformation Ratio Voltage output
Output Signal 5A: 200mV/A
100A: 10mV/A
Frequency Range 40 to 10kHz
Limit Operating Conditions 200A MAX to 1kHz
Derating above 1kHz: 200A x (1*F), F in kHz
Working Voltage 600Vrms
Common Mode Voltage 600Vrms
Influence of Adjacent Conductor < 15mA/A at 50Hz
Influence of DC on AC signal 5A Range: DC Current < 1A, < 3%
100A Range: DC Current < 10A, < 10%
Influence of Conductor Position in Jaw 0.5% of mV output at 50/60Hz
Influence of Frequency 5A Range: 40Hz to 1kHz: <0.7% of mV output; 1kHz to 3kHz: <2%% of mV output
150A Range: 40Hz to 1kHz: <0.7% of mV output; 1kHz to 3kHz: <0.7% of mV output
Influence of Temperature ≤200 ppm/°K, or 0.2% of mV output per 10°K
Influence of Humidity (10 to 90% RH) ≤0.2% of mV output per 10°K at 18° to 28°C 
Click here for complete specifications on the AEMC Instruments MN379

What's included with the AEMC Instruments MN379

  • AEMC MN379 AC Current Probe, Lead, 5A/100A

Ask a question about AEMC MN379 AC Current Probe, Lead, 5A/100A

Customer Reviews for the AEMC Instruments MN379

More AEMC Instruments Products