Reliable and versatile, this clamp-on meter measures temperature, current, voltage, frequency, continuity with a buzzer, and resistance and performs a diode test. In addition, this meter handles 1000 A AC/1500 A DC and features True InRush® technology, allowing you to measure inrush current and overcurrent with precision.
Reliable and versatile, this clamp-on meter measures temperature, current, voltage, frequency, continuity with a buzzer, and resistance and performs a diode test. In addition, this meter handles 1000 A AC/1500 A DC and features True InRush® technology, allowing you to measure inrush current and overcurrent with precision.
Work with fast and accurate electrical measurements with this user-friendly and efficient meter, making it the perfect choice for any commercial or residential project. In addition, this meter features an adapter function, for easy use with external transducers or measurement devices.
Features
A range offering unprecedented analytical and diagnostic functions!
TRMS version of Min and Max: The Min and Max are TRMS values calculated over a duration of up to 100 ms. This feature is particularly useful for sizing an installation, the diameter of a power cable, a thermal protection device, etc.
Peak+ and Peak-: Calculated over a period of 1 ms, the Peak+ and Peak- values help to characterize the distortion affecting the signal measured. For example, they may reveal variations in the installation's behavior or even malfunctions.
ΔREL, for quick evaluation: Comparison with a reference quantity is a quick way of evaluating and analyzing your results. A signal's variations can be measured differentially or relatively. The first method indicates the difference between the value of reference and the value measured. The second method indicates the proportion. The ΔRELfunction can be applied to any type of measurement and can be used jointly with the Min, Max and Peak functions
Feature rich clamp-on meter
Ideal tool for any work in the field and is simple to use and groups all the necessary functions in a single, compact solution. Leveraging cutting-edge technology, this meter guarantees top-notch quality while ensuring user-friendly simplicity.
Performance
Benefit from a fast 12-bit TRMS digital acquisition system offering high measurement accuracy. Thanks to it's large bandwidth and high crest factor, this clamp provides accurate measurements whatever the signal type.
Ergonomics
The entire range is designed for one-handed use, even when wearing safety gloves. For maximum efficiency, each measurement corresponds to a specific switch position. The one key, one function concept makes it even easier to use. In addition, this clamp is equipped with automatic detection of the type of signal (AC or DC) on currents, voltages, and power values.
True InRush® function
True InRush® function provides the unique ability to measure power-up events from devices on a network that is already energized. Unlike other instruments which only measure the inrush when the installation is first powered up, our power clamp-on meters measure all types of inrush, even those due to load increases on an installation which is already up and running.
Applications
DC Voltage Measurement | Measurement range: 0 to 99.99 V Specified measurement range: 0 to 1600 V Accuracy: 0 to 9.99 V ± (1% R + 10 cts)/10 to 99.99 V ± (1% R + 3 cts) Resolution: 0.01 V Input impedance: 10 MΩ Measurement range: 100 to 999.9 V Specified measurement range: 0 to 1600 V Resolution: 0.1 V Input impedance: 10 MΩ Measurement range: 1000 to 1700 V1) Specified measurement range: 0 to 1600 V Resolution: 1 V Input impedance: 10 MΩ 1)The display indicates +OL above 3400 V and -OL below - 3400 V, in REL mode. Above 1700 V, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed. *Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
AC Voltage Measurement | Measurement range: 0.15 to 99.99 V Specified measurement range2): 0 to 1100 V AC/1600 V peak Accuracy: 0.15 to 9.99 V ± (1% R+ 10 cts)/10 to 99.99 V ± (1% R + 3cts) Resolution: 0.01 V Input impedance: 10 MΩ 100 to 999.9 V Specified measurement range2): 0 to 1100 V AC/1600 V peak Accuracy: ± (1% R + 4 cts) Resolution 0.1 V Input impedance: 10 MΩ Measurement range: 1000 to 1200 V RMS/1700 V peak1) Specified measurement range2): 0 to 1100 V AC/1600 V peak Accuracy: ± (1% R + 4 cts) Resolution 1 V Input impedance: 10 MΩ 1)The display indicates OL above 1700 V. Above 1200 V RMS, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed bandwidth in AC = 3 kHz. 2)Any value between zero and the min threshold of the measurement range (0.15 V) is forced to ---- on the display. *Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
DC Current Measurement | Measurement range2): 0 to 99.99 A Specified measurement range: 0 to 100% of the measurement range Accuracy (zero corrected)2): ± (1% R + 10 cts) Resolution: 0.01 A Measurement range: 100 to 999.9 A Specified measurement range: 0 to 100% of the measurement range Accuracy (zero corrected)2): (1% R + 3 cts) Resolution: 0.1 A Measurement range: 1000 to 1500 A1) Specified measurement range: 0 to 100% of the measurement range Accuracy (zero corrected)2):(1.5% R + 3 cts) Resolution: 1 A 1)The display indicates +OL above 3000 A and -OL below -3000 A in REL mode. The - and + signs are displayed (polarity). 2)The residual current at zero depends on the remanence, it can be corrected by the DC zero function of the HOLD button. *Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
AC Current Measurement | Measurement range2): 0.25 to 99.99 A Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (1% R + 10 cts) Resolution: 0.01 A Measurement range2): 100 to 999.9 A Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (1% R + 3 cts) Resolution: 0.1 A Measurement range2): 1000 A (15,000 A peak)1) Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (1% R + 3 cts) Resolution: 1 A 1)The display indicates OL above 1500 A in PEAK mode. The - and + signs are not displayed. Bandwidth in AC = 2 kHz. 2)In AC, any value between zero and the min. threshold of the measurement range (0.25 A) is forced to show ----on the display *Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
True InRush Measurement | Measurement range: 10 A to 1000 A AC/10 A to 1500 A DC Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (5% R + 5 cts) Resolution: 1 A Peak mode: Accuracy: Add ± (1.5% R + 0.5 A) to the values above Peak capture time: 1 ms minimum to 1.5 ms maximum |
Continuity Measurement | Measurement range: 0 to 999.9 Ω Open-circuit voltage: ≤3.6 V Measurement current: 550 μA Accuracy: ± (1% R + 5 cts) Buzzer triggering threshold: Adjustable from (1 to 999) Ω (40 Ω is the default) |
Resistance Measurement | Measurement range1): 0 to 99.9 Ω Specified measurement range: 1 to 100% of the measurement range Accuracy: ± (1% R + 10 cts) Resolution: 0.1 Ω Open-circuit voltage: ≤3.6 V Measurement current: 550 μA Measurement range1): 100 to 999.9 Ω Specified measurement range: 1 to 100% of the measurement range Accuracy: ± (1% R + 5 cts) Resolution: 0.1 Ω Open-circuit voltage: ≤3.6 V Measurement current: 500 μA Measurement range1): 10 to 9999 kΩ Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (1% R + 5 cts) Resolution: 1 Ω Open-circuit voltage: ≤3.6 V Measurement current: 100 μA Measurement range1): 10 to 99.99 kΩ Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (1% R + 5 cts) Resolution: 10 Ω Open-circuit voltage: ≤3.6 V Measurement current: 10 μA MAX/MIN mode: Accuracy: add 1% R to the values above Capture of the extreme: Approximately 100 ms 1)Above the maximum display value, the display unit indicates OL. The - and + signs are not displayed. |
Diode Test | Measurement range: 0 to 3.199 V DC Specified measurement range: 1 to 100% of the measurement range Accuracy: ± (1% R + 10 cts) Resolution: 0.001 V Measurement current: 0.55 mA Indication (junction reversed or open circuit): OL is displayed when the measured voltage >3.199 V |
Frequency Voltage Measurement | Measurement range1): 5 to 999.9 Hz Specified measurement range: 1 to 100% of the measurement range Accuracy: ±0.4% R + 1 ct Resolution: 0.1 Hz Measurement range1): 1000 to 9999 hZ Specified measurement range: 0 to 100% of the measurement range Accuracy: ±0.4% R + 1 ct Resolution: 1 Hz Measurement range1): 10 to 19.99 kHz Specified measurement range: 0 to 100% of the measurement range Accuracy: ±0.4% R + 1 ct Resolution: 10 Hz MAX/MIN mode (from 10 Hz to 1 kHz) for voltage and current: Accuracy: Add 1% R to the values above Capture time of the extreme: Approximately 100 ms 1)In MAX/MIN mode, the operating range is limited to 1 kHz. If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays ---- |
Frequency Current Measurement | Measurement range1): 5 to 999.9 Hz Specified measurement range: 1 to 100% of the measurement range Accuracy: ± 0.4% R + 1 ct Resolution: 0.1 Hz MAX/MIN mode (from 10 Hz to 1 kHz) for voltage and current: Accuracy: Add 1% R to the values above Capture time of the extreme: Approximately 100 ms 1)In MAX/MIN mode, the operating range is limited to 1 kHz. If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays ---- |
Temperature Measurement | Type of sensor K-thermocouple Measurement range: 76 to 1831.8°F (-60 to 999.9°C)/1832 to 2192°F (1000 to 1200°C) Specified measurement range: 1 to 100% of the measurement range Accuracy1): 1% R ±5.4°F (1% R ±3°C) Resolution: 0.1°F (0.1°C) MAX/MIN mode (10 Hz to 1 kHz): Accuracy: Add 1% R to the values above Capture time of the extreme: Approximately 100 ms 1)The stated external temperature measurement accuracy does not take the accuracy of the K-thermocouple into account. *NOTE: Use of the thermal time constant (0.7 min/°C): If there is a sudden variation of the temperature of the clamp, by 50°F (10°C) for example, the clamp will be at 99% (cnst = 5) of the final temperature after 0.7 min/°C x 5 to 35 min (the time constant of the external sensor must be added to this value). |
Adapter Function Measurement in DC Mode | Measurement range1): 0 to 999.9 mV Specified measurement range2): 0 to 100% of the measurement range Accuracy: 1% R + 3 cts Resolution: 0.1 mV Input impedance: 10 MΩ Measurement range1): 1 to 9.99 V Specified measurement range2): 0 to 100% of the measurement range Accuracy: 1% R + 3 cts Resolution: 10 mV Input impedance: 10 MΩ MAX/MIN mode (from 10 Hz to 1 kHz): Accuracy: Add 1% R to the values above Capture of the extreme: Approximately 100 ms 1)The basic display is 10,000 counts. The position of the decimal count and the display of multiples (m and k) depend on the programming of the scale factor. -In DC, the display indicates +OL above +9999 counts and -OL below -9999 counts. The - and + signs are displayed (polarity). -In AC, the display indicates OL above 9999 counts. 2)The maximum bandwidth is 1 kHz. |
Adapter Function Measurement in AC Mode | Measurement range1): 5 to 999.9 mV Specified measurement range2): 0 to 100% of the measurement range Accuracy: 5 to 99.9 mV ± 1% R + 10 cts/100 to 999.9 mV ± 1% R + 3 cts Resolution: 0.1 mV Input impedance: 10 MΩ Measurement range1): 1 to 9.99 V Specified measurement range2): 0 to 100% of the measurement range Accuracy: 1% R + 3 cts Resolution: 10 mV Input impedance: 10 MΩ MAX/MIN mode (from 10 Hz to 1 kHz): Accuracy: Add 1% R to the values above Capture of the extreme: Approximately 100 ms 1)The basic display is 10,000 counts. The position of the decimal count and the display of multiples (m and k) depend on the programming of the scale factor. -In DC, the display indicates +OL above +9999 counts and -OL below -9999 counts. The - and + signs are displayed (polarity). -In AC, the display indicates OL above 9999 counts. 2)The maximum bandwidth is 1 kHz. |
Screen | LCD unit Blue backlighting |
Temperature | Operating: -4 to 131°F (-20 to 55°C) Storage: -40 to 158°F (-40 to 70°C) |
Relative Humidity (RH) | Operating: ≤90% up to 131°F (55°C) Storage: ≤90% up to 158°F (70°C) |
Power Supply | Batteries: 4 x 1.5 V AA LR6 Battery life: >350 hours (without backlighting) Auto power off: After 10 minutes with no switch and/or button activity |
Compliance with International Standards | Electric safety: Compliant with standards IEC/EN 61010-1 or BS EN 61010-1, IEC/EN 61010-2-032 or BS EN 61010-2-032: 1000 V CAT IV and 1500 V CAT III Electromagnetic compatibility: Compliant with standard EN-61326-1 or BS EN 61326-1, classification: residential environment Mechanical strength: Free fall: 3.28' (2 m), in accordance with standard IEC-68-2-32 Level of protection: Housing IP54 (per standard IEC-60529)/Jaws: IP40 |
Housing | Rigid polycarbonate shell with over-molded elastomer covering; UL94 V1 |
Jaws | Polycarbonate Opening: 1.9" (48 mm) Clamping diameter: 1.9" (48 mm) |
Dimensions | 10.7 x 3.6 x 1.6" (272 x 92 x 41 mm) Screen: 1.6 x 1.9" (41 x 48 mm) |
Weight | 1.32 lbs (600 g) with the batteries |
Click on a category to view a selection of compatible accessories with the AEMC 404 Clamp-On Meter, 1000 A AC/1500 A DC, temperature.
DC Voltage Measurement | Measurement range: 0 to 99.99 V Specified measurement range: 0 to 1600 V Accuracy: 0 to 9.99 V ± (1% R + 10 cts)/10 to 99.99 V ± (1% R + 3 cts) Resolution: 0.01 V Input impedance: 10 MΩ Measurement range: 100 to 999.9 V Specified measurement range: 0 to 1600 V Resolution: 0.1 V Input impedance: 10 MΩ Measurement range: 1000 to 1700 V1) Specified measurement range: 0 to 1600 V Resolution: 1 V Input impedance: 10 MΩ 1)The display indicates +OL above 3400 V and -OL below - 3400 V, in REL mode. Above 1700 V, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed. *Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
AC Voltage Measurement | Measurement range: 0.15 to 99.99 V Specified measurement range2): 0 to 1100 V AC/1600 V peak Accuracy: 0.15 to 9.99 V ± (1% R+ 10 cts)/10 to 99.99 V ± (1% R + 3cts) Resolution: 0.01 V Input impedance: 10 MΩ 100 to 999.9 V Specified measurement range2): 0 to 1100 V AC/1600 V peak Accuracy: ± (1% R + 4 cts) Resolution 0.1 V Input impedance: 10 MΩ Measurement range: 1000 to 1200 V RMS/1700 V peak1) Specified measurement range2): 0 to 1100 V AC/1600 V peak Accuracy: ± (1% R + 4 cts) Resolution 1 V Input impedance: 10 MΩ 1)The display indicates OL above 1700 V. Above 1200 V RMS, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed bandwidth in AC = 3 kHz. 2)Any value between zero and the min threshold of the measurement range (0.15 V) is forced to ---- on the display. *Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
DC Current Measurement | Measurement range2): 0 to 99.99 A Specified measurement range: 0 to 100% of the measurement range Accuracy (zero corrected)2): ± (1% R + 10 cts) Resolution: 0.01 A Measurement range: 100 to 999.9 A Specified measurement range: 0 to 100% of the measurement range Accuracy (zero corrected)2): (1% R + 3 cts) Resolution: 0.1 A Measurement range: 1000 to 1500 A1) Specified measurement range: 0 to 100% of the measurement range Accuracy (zero corrected)2):(1.5% R + 3 cts) Resolution: 1 A 1)The display indicates +OL above 3000 A and -OL below -3000 A in REL mode. The - and + signs are displayed (polarity). 2)The residual current at zero depends on the remanence, it can be corrected by the DC zero function of the HOLD button. *Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
AC Current Measurement | Measurement range2): 0.25 to 99.99 A Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (1% R + 10 cts) Resolution: 0.01 A Measurement range2): 100 to 999.9 A Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (1% R + 3 cts) Resolution: 0.1 A Measurement range2): 1000 A (15,000 A peak)1) Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (1% R + 3 cts) Resolution: 1 A 1)The display indicates OL above 1500 A in PEAK mode. The - and + signs are not displayed. Bandwidth in AC = 2 kHz. 2)In AC, any value between zero and the min. threshold of the measurement range (0.25 A) is forced to show ----on the display *Accuracy is expressed in ± (x % of the reading (R) + y counts (ct)) |
True InRush Measurement | Measurement range: 10 A to 1000 A AC/10 A to 1500 A DC Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (5% R + 5 cts) Resolution: 1 A Peak mode: Accuracy: Add ± (1.5% R + 0.5 A) to the values above Peak capture time: 1 ms minimum to 1.5 ms maximum |
Continuity Measurement | Measurement range: 0 to 999.9 Ω Open-circuit voltage: ≤3.6 V Measurement current: 550 μA Accuracy: ± (1% R + 5 cts) Buzzer triggering threshold: Adjustable from (1 to 999) Ω (40 Ω is the default) |
Resistance Measurement | Measurement range1): 0 to 99.9 Ω Specified measurement range: 1 to 100% of the measurement range Accuracy: ± (1% R + 10 cts) Resolution: 0.1 Ω Open-circuit voltage: ≤3.6 V Measurement current: 550 μA Measurement range1): 100 to 999.9 Ω Specified measurement range: 1 to 100% of the measurement range Accuracy: ± (1% R + 5 cts) Resolution: 0.1 Ω Open-circuit voltage: ≤3.6 V Measurement current: 500 μA Measurement range1): 10 to 9999 kΩ Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (1% R + 5 cts) Resolution: 1 Ω Open-circuit voltage: ≤3.6 V Measurement current: 100 μA Measurement range1): 10 to 99.99 kΩ Specified measurement range: 0 to 100% of the measurement range Accuracy: ± (1% R + 5 cts) Resolution: 10 Ω Open-circuit voltage: ≤3.6 V Measurement current: 10 μA MAX/MIN mode: Accuracy: add 1% R to the values above Capture of the extreme: Approximately 100 ms 1)Above the maximum display value, the display unit indicates OL. The - and + signs are not displayed. |
Diode Test | Measurement range: 0 to 3.199 V DC Specified measurement range: 1 to 100% of the measurement range Accuracy: ± (1% R + 10 cts) Resolution: 0.001 V Measurement current: 0.55 mA Indication (junction reversed or open circuit): OL is displayed when the measured voltage >3.199 V |
Frequency Voltage Measurement | Measurement range1): 5 to 999.9 Hz Specified measurement range: 1 to 100% of the measurement range Accuracy: ±0.4% R + 1 ct Resolution: 0.1 Hz Measurement range1): 1000 to 9999 hZ Specified measurement range: 0 to 100% of the measurement range Accuracy: ±0.4% R + 1 ct Resolution: 1 Hz Measurement range1): 10 to 19.99 kHz Specified measurement range: 0 to 100% of the measurement range Accuracy: ±0.4% R + 1 ct Resolution: 10 Hz MAX/MIN mode (from 10 Hz to 1 kHz) for voltage and current: Accuracy: Add 1% R to the values above Capture time of the extreme: Approximately 100 ms 1)In MAX/MIN mode, the operating range is limited to 1 kHz. If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays ---- |
Frequency Current Measurement | Measurement range1): 5 to 999.9 Hz Specified measurement range: 1 to 100% of the measurement range Accuracy: ± 0.4% R + 1 ct Resolution: 0.1 Hz MAX/MIN mode (from 10 Hz to 1 kHz) for voltage and current: Accuracy: Add 1% R to the values above Capture time of the extreme: Approximately 100 ms 1)In MAX/MIN mode, the operating range is limited to 1 kHz. If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays ---- |
Temperature Measurement | Type of sensor K-thermocouple Measurement range: 76 to 1831.8°F (-60 to 999.9°C)/1832 to 2192°F (1000 to 1200°C) Specified measurement range: 1 to 100% of the measurement range Accuracy1): 1% R ±5.4°F (1% R ±3°C) Resolution: 0.1°F (0.1°C) MAX/MIN mode (10 Hz to 1 kHz): Accuracy: Add 1% R to the values above Capture time of the extreme: Approximately 100 ms 1)The stated external temperature measurement accuracy does not take the accuracy of the K-thermocouple into account. *NOTE: Use of the thermal time constant (0.7 min/°C): If there is a sudden variation of the temperature of the clamp, by 50°F (10°C) for example, the clamp will be at 99% (cnst = 5) of the final temperature after 0.7 min/°C x 5 to 35 min (the time constant of the external sensor must be added to this value). |
Adapter Function Measurement in DC Mode | Measurement range1): 0 to 999.9 mV Specified measurement range2): 0 to 100% of the measurement range Accuracy: 1% R + 3 cts Resolution: 0.1 mV Input impedance: 10 MΩ Measurement range1): 1 to 9.99 V Specified measurement range2): 0 to 100% of the measurement range Accuracy: 1% R + 3 cts Resolution: 10 mV Input impedance: 10 MΩ MAX/MIN mode (from 10 Hz to 1 kHz): Accuracy: Add 1% R to the values above Capture of the extreme: Approximately 100 ms 1)The basic display is 10,000 counts. The position of the decimal count and the display of multiples (m and k) depend on the programming of the scale factor. -In DC, the display indicates +OL above +9999 counts and -OL below -9999 counts. The - and + signs are displayed (polarity). -In AC, the display indicates OL above 9999 counts. 2)The maximum bandwidth is 1 kHz. |
Adapter Function Measurement in AC Mode | Measurement range1): 5 to 999.9 mV Specified measurement range2): 0 to 100% of the measurement range Accuracy: 5 to 99.9 mV ± 1% R + 10 cts/100 to 999.9 mV ± 1% R + 3 cts Resolution: 0.1 mV Input impedance: 10 MΩ Measurement range1): 1 to 9.99 V Specified measurement range2): 0 to 100% of the measurement range Accuracy: 1% R + 3 cts Resolution: 10 mV Input impedance: 10 MΩ MAX/MIN mode (from 10 Hz to 1 kHz): Accuracy: Add 1% R to the values above Capture of the extreme: Approximately 100 ms 1)The basic display is 10,000 counts. The position of the decimal count and the display of multiples (m and k) depend on the programming of the scale factor. -In DC, the display indicates +OL above +9999 counts and -OL below -9999 counts. The - and + signs are displayed (polarity). -In AC, the display indicates OL above 9999 counts. 2)The maximum bandwidth is 1 kHz. |
Screen | LCD unit Blue backlighting |
Temperature | Operating: -4 to 131°F (-20 to 55°C) Storage: -40 to 158°F (-40 to 70°C) |
Relative Humidity (RH) | Operating: ≤90% up to 131°F (55°C) Storage: ≤90% up to 158°F (70°C) |
Power Supply | Batteries: 4 x 1.5 V AA LR6 Battery life: >350 hours (without backlighting) Auto power off: After 10 minutes with no switch and/or button activity |
Compliance with International Standards | Electric safety: Compliant with standards IEC/EN 61010-1 or BS EN 61010-1, IEC/EN 61010-2-032 or BS EN 61010-2-032: 1000 V CAT IV and 1500 V CAT III Electromagnetic compatibility: Compliant with standard EN-61326-1 or BS EN 61326-1, classification: residential environment Mechanical strength: Free fall: 3.28' (2 m), in accordance with standard IEC-68-2-32 Level of protection: Housing IP54 (per standard IEC-60529)/Jaws: IP40 |
Housing | Rigid polycarbonate shell with over-molded elastomer covering; UL94 V1 |
Jaws | Polycarbonate Opening: 1.9" (48 mm) Clamping diameter: 1.9" (48 mm) |
Dimensions | 10.7 x 3.6 x 1.6" (272 x 92 x 41 mm) Screen: 1.6 x 1.9" (41 x 48 mm) |
Weight | 1.32 lbs (600 g) with the batteries |
Click on a category to view a selection of compatible accessories with the AEMC 404 Clamp-On Meter, 1000 A AC/1500 A DC, temperature.