Reliable and versatile, this clamp-on meter measures temperature, current, voltage, frequency, continuity with a buzzer, and resistance and performs a diode test. In addition, this meter handles 1000 A AC/1500 A DC and features True InRush® technology, allowing you to measure inrush current and overcurrent with precision.

Reliable and versatile, this clamp-on meter measures temperature, current, voltage, frequency, continuity with a buzzer, and resistance and performs a diode test. In addition, this meter handles 1000 A AC/1500 A DC and features True InRush® technology, allowing you to measure inrush current and overcurrent with precision.

Sale Price $663.94 CAD
Regular Price $746.00 CAD
Availability 2 to 3 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 404 Clamp-On Meter

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 404 Clamp-On Meter

AEMC Instruments 404 Offers

Work with fast and accurate electrical measurements with this user-friendly and efficient meter, making it the perfect choice for any commercial or residential project. In addition, this meter features an adapter function, for easy use with external transducers or measurement devices.

Features

  • Large 10,000-count blue electroluminescent backlit display
  • Measures frequency to 20 kHz with 0.1 Hz resolution
  • Current measurement
  • Measurement of Inrush current/overcurrent (True InRush®) with 100 mS capture
  • Voltage measurement
  • Frequency measurement
  • Continuity test with buzzer
  • Resistance measurement
  • Diode test
  • Temperature measurement
  • Adapter function (for use with external transducers/measurement devices)
  • Jaws with centering marks opening up to 1.89" (48 mm)
  • Physical guard
  • Rotary function switch
  • Function buttons
  • Backlit display
  • Input terminals
  • Trigger
  • Battery compartment and compartment screw
  • K-thermocouple with 0.16" (4 mm) integrated adapter
  • 1700 V DC/1200 V AC measurements
  • 1000 V CAT IV/1500 V CAT III safety rated
  • UL94 VI flame retardant self-extinguishing
  • Auto selects AC or DC measurement voltage
  • IP54: This meter is rugged enough for the most demanding work environments and will withstand both dust and water spray, guaranteeing its safety level over time
  • Auto power OFF
  • Hold button
  • Backlight button
  • Min/Max button
  • Relative function
  • Hz button

A range offering unprecedented analytical and diagnostic functions!

TRMS version of Min and Max: The Min and Max are TRMS values calculated over a duration of up to 100 ms. This feature is particularly useful for sizing an installation, the diameter of a power cable, a thermal protection device, etc.

Peak+ and Peak-: Calculated over a period of 1 ms, the Peak+ and Peak- values help to characterize the distortion affecting the signal measured. For example, they may reveal variations in the installation's behavior or even malfunctions.

ΔREL, for quick evaluation: Comparison with a reference quantity is a quick way of evaluating and analyzing your results. A signal's variations can be measured differentially or relatively. The first method indicates the difference between the value of reference and the value measured. The second method indicates the proportion. The ΔRELfunction can be applied to any type of measurement and can be used jointly with the Min, Max and Peak functions

Feature rich clamp-on meter

Ideal tool for any work in the field and is simple to use and groups all the necessary functions in a single, compact solution. Leveraging cutting-edge technology, this meter guarantees top-notch quality while ensuring user-friendly simplicity.

Performance

Benefit from a fast 12-bit TRMS digital acquisition system offering high measurement accuracy. Thanks to it's large bandwidth and high crest factor, this clamp provides accurate measurements whatever the signal type.

Ergonomics

The entire range is designed for one-handed use, even when wearing safety gloves. For maximum efficiency, each measurement corresponds to a specific switch position. The one key, one function concept makes it even easier to use. In addition, this clamp is equipped with automatic detection of the type of signal (AC or DC) on currents, voltages, and power values.

True InRush® function

True InRush® function provides the unique ability to measure power-up events from devices on a network that is already energized. Unlike other instruments which only measure the inrush when the installation is first powered up, our power clamp-on meters measure all types of inrush, even those due to load increases on an installation which is already up and running.

Applications

  • Photovoltaic (PV)
  • Solar panel, inverter testing, comissioning, engineers, and technicians
  • Solar comissioning
  • Low and medium power low voltage locations
  • AC or DC motor testing
  • Electrical power distribution, contractors, and maintenance
  • Commercial, industrial, residential and HVAC/R troubleshooting
  • Safety lighting system maintenance
  • Automotive test troubleshooting
  • Hospitals
  • Field service agencies and technicians
  • Government agencies
  • Educational institutions
  • Plant maintenance personnel
  • Electric utility power quality engineers
  • Railway
  • Lift/elevator technicians
  • Other lift or transport equipment specialists

AEMC Instruments 404 Specifications

DC Voltage Measurement Measurement range: 0 to 99.99 V
Specified measurement range: 0 to 1600 V
Accuracy: 0 to 9.99 V ± (1% R + 10 cts)/10 to 99.99 V ± (1% R + 3 cts)
Resolution: 0.01 V
Input impedance: 10 MΩ

Measurement range: 100 to 999.9 V
Specified measurement range: 0 to 1600 V
Resolution: 0.1 V
Input impedance: 10 MΩ

Measurement range: 1000 to 1700 V1)
Specified measurement range: 0 to 1600 V
Resolution: 1 V
Input impedance: 10 MΩ
1)The display indicates +OL above 3400 V and -OL below - 3400 V, in REL mode. Above 1700 V, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed.
*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct))
AC Voltage Measurement Measurement range: 0.15 to 99.99 V
Specified measurement range2): 0 to 1100 V AC/1600 V peak
Accuracy: 0.15 to 9.99 V ± (1% R+ 10 cts)/10 to 99.99 V ± (1% R + 3cts)
Resolution: 0.01 V
Input impedance: 10 MΩ

100 to 999.9 V
Specified measurement range2): 0 to 1100 V AC/1600 V peak
Accuracy: ± (1% R + 4 cts)
Resolution 0.1 V
Input impedance: 10 MΩ

Measurement range: 1000 to 1200 V RMS/1700 V peak1)
Specified measurement range2): 0 to 1100 V AC/1600 V peak
Accuracy: ± (1% R + 4 cts)
Resolution 1 V
Input impedance: 10 MΩ
1)The display indicates OL above 1700 V. Above 1200 V RMS, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed bandwidth in AC = 3 kHz.
2)Any value between zero and the min threshold of the measurement range (0.15 V) is forced to ---- on the display.
*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct))
DC Current Measurement Measurement range2): 0 to 99.99 A
Specified measurement range: 0 to 100% of the measurement range
Accuracy (zero corrected)2): ± (1% R + 10 cts)
Resolution: 0.01 A

Measurement range: 100 to 999.9 A
Specified measurement range: 0 to 100% of the measurement range
Accuracy (zero corrected)2): (1% R + 3 cts)
Resolution: 0.1 A

Measurement range: 1000 to 1500 A1)
Specified measurement range: 0 to 100% of the measurement range
Accuracy (zero corrected)2):(1.5% R + 3 cts)
Resolution: 1 A
1)The display indicates +OL above 3000 A and -OL below -3000 A in REL mode. The - and + signs are displayed (polarity).
2)The residual current at zero depends on the remanence, it can be corrected by the DC zero function of the HOLD button.
*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct))
AC Current Measurement Measurement range2): 0.25 to 99.99 A
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (1% R + 10 cts)
Resolution: 0.01 A

Measurement range2): 100 to 999.9 A
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (1% R + 3 cts)
Resolution: 0.1 A

Measurement range2): 1000 A (15,000 A peak)1)
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (1% R + 3 cts)
Resolution: 1 A
1)The display indicates OL above 1500 A in PEAK mode. The - and + signs are not displayed. Bandwidth in AC = 2 kHz.
2)In AC, any value between zero and the min. threshold of the measurement range (0.25 A) is forced to show ----on the display
*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct))
True InRush Measurement Measurement range: 10 A to 1000 A AC/10 A to 1500 A DC
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (5% R + 5 cts)
Resolution: 1 A

Peak mode:
Accuracy: Add ± (1.5% R + 0.5 A) to the values above
Peak capture time: 1 ms minimum to 1.5 ms maximum
Continuity Measurement Measurement range: 0 to 999.9 Ω
Open-circuit voltage: ≤3.6 V
Measurement current: 550 μA
Accuracy: ± (1% R + 5 cts)
Buzzer triggering threshold: Adjustable from (1 to 999) Ω (40 Ω is the default)
Resistance Measurement Measurement range1): 0 to 99.9 Ω
Specified measurement range: 1 to 100% of the measurement range
Accuracy: ± (1% R + 10 cts)
Resolution: 0.1 Ω
Open-circuit voltage: ≤3.6 V
Measurement current: 550 μA

Measurement range1): 100 to 999.9 Ω
Specified measurement range: 1 to 100% of the measurement range
Accuracy: ± (1% R + 5 cts)
Resolution: 0.1 Ω
Open-circuit voltage: ≤3.6 V
Measurement current: 500 μA

Measurement range1): 10 to 9999 kΩ
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (1% R + 5 cts)
Resolution: 1 Ω
Open-circuit voltage: ≤3.6 V
Measurement current: 100 μA

Measurement range1): 10 to 99.99 kΩ
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (1% R + 5 cts)
Resolution: 10 Ω
Open-circuit voltage: ≤3.6 V
Measurement current: 10 μA

MAX/MIN mode:
Accuracy: add 1% R to the values above
Capture of the extreme: Approximately 100 ms
1)Above the maximum display value, the display unit indicates OL. The - and + signs are not displayed.
Diode Test Measurement range: 0 to 3.199 V DC
Specified measurement range: 1 to 100% of the measurement range
Accuracy: ± (1% R + 10 cts)
Resolution: 0.001 V
Measurement current: 0.55 mA
Indication (junction reversed or open circuit): OL is displayed when the measured voltage >3.199 V
Frequency Voltage Measurement Measurement range1): 5 to 999.9 Hz
Specified measurement range: 1 to 100% of the measurement range
Accuracy: ±0.4% R + 1 ct
Resolution: 0.1 Hz

Measurement range1): 1000 to 9999 hZ
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ±0.4% R + 1 ct
Resolution: 1 Hz

Measurement range1): 10 to 19.99 kHz
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ±0.4% R + 1 ct
Resolution: 10 Hz

MAX/MIN mode (from 10 Hz to 1 kHz) for voltage and current: Accuracy: Add 1% R to the values above
Capture time of the extreme: Approximately 100 ms
1)In MAX/MIN mode, the operating range is limited to 1 kHz. If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays ----
Frequency Current Measurement Measurement range1): 5 to 999.9 Hz
Specified measurement range: 1 to 100% of the measurement range
Accuracy: ± 0.4% R + 1 ct
Resolution: 0.1 Hz

MAX/MIN mode (from 10 Hz to 1 kHz) for voltage and current: Accuracy: Add 1% R to the values above
Capture time of the extreme: Approximately 100 ms
1)In MAX/MIN mode, the operating range is limited to 1 kHz. If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays ----
Temperature Measurement Type of sensor K-thermocouple
Measurement range: 76 to 1831.8°F (-60 to 999.9°C)/1832 to 2192°F (1000 to 1200°C)
Specified measurement range: 1 to 100% of the measurement range
Accuracy1): 1% R ±5.4°F (1% R ±3°C)
Resolution: 0.1°F (0.1°C)

MAX/MIN mode (10 Hz to 1 kHz):
Accuracy: Add 1% R to the values above
Capture time of the extreme: Approximately 100 ms
1)The stated external temperature measurement accuracy does not take the accuracy of the K-thermocouple into account.
*NOTE: Use of the thermal time constant (0.7 min/°C): If there is a sudden variation of the temperature of the clamp, by 50°F (10°C) for example, the clamp will be at 99% (cnst = 5) of the final temperature after 0.7 min/°C x 5 to 35 min (the time constant of the external sensor must be added to this value).
Adapter Function Measurement in DC Mode Measurement range1): 0 to 999.9 mV
Specified measurement range2): 0 to 100% of the measurement range
Accuracy: 1% R + 3 cts
Resolution: 0.1 mV
Input impedance: 10 MΩ

Measurement range1): 1 to 9.99 V
Specified measurement range2): 0 to 100% of the measurement range
Accuracy: 1% R + 3 cts
Resolution: 10 mV
Input impedance: 10 MΩ

MAX/MIN mode (from 10 Hz to 1 kHz): Accuracy: Add 1% R to the values above
Capture of the extreme: Approximately 100 ms
1)The basic display is 10,000 counts. The position of the decimal count and the display of multiples (m and k) depend on the programming of the scale factor. -In DC, the display indicates +OL above +9999 counts and -OL below -9999 counts. The - and + signs are displayed (polarity). -In AC, the display indicates OL above 9999 counts.
2)The maximum bandwidth is 1 kHz.
Adapter Function Measurement in AC Mode Measurement range1): 5 to 999.9 mV
Specified measurement range2): 0 to 100% of the measurement range
Accuracy: 5 to 99.9 mV ± 1% R + 10 cts/100 to 999.9 mV ± 1% R + 3 cts
Resolution: 0.1 mV
Input impedance: 10 MΩ

Measurement range1): 1 to 9.99 V
Specified measurement range2): 0 to 100% of the measurement range
Accuracy: 1% R + 3 cts
Resolution: 10 mV
Input impedance: 10 MΩ

MAX/MIN mode (from 10 Hz to 1 kHz): Accuracy: Add 1% R to the values above
Capture of the extreme: Approximately 100 ms
1)The basic display is 10,000 counts. The position of the decimal count and the display of multiples (m and k) depend on the programming of the scale factor. -In DC, the display indicates +OL above +9999 counts and -OL below -9999 counts. The - and + signs are displayed (polarity). -In AC, the display indicates OL above 9999 counts.
2)The maximum bandwidth is 1 kHz.
Screen LCD unit
Blue backlighting
Temperature Operating: -4 to 131°F (-20 to 55°C)
Storage: -40 to 158°F (-40 to 70°C)
Relative Humidity (RH) Operating: ≤90% up to 131°F (55°C)
Storage: ≤90% up to 158°F (70°C)
Power Supply Batteries: 4 x 1.5 V AA LR6
Battery life: >350 hours (without backlighting)
Auto power off: After 10 minutes with no switch and/or button activity
Compliance with International Standards Electric safety: Compliant with standards IEC/EN 61010-1 or BS EN 61010-1, IEC/EN 61010-2-032 or BS EN 61010-2-032: 1000 V CAT IV and 1500 V CAT III
Electromagnetic compatibility: Compliant with standard EN-61326-1 or BS EN 61326-1, classification: residential environment
Mechanical strength: Free fall: 3.28' (2 m), in accordance with standard IEC-68-2-32
Level of protection: Housing IP54 (per standard IEC-60529)/Jaws: IP40
Housing Rigid polycarbonate shell with over-molded elastomer covering; UL94 V1
Jaws Polycarbonate
Opening: 1.9" (48 mm)
Clamping diameter: 1.9" (48 mm)
Dimensions 10.7 x 3.6 x 1.6" (272 x 92 x 41 mm)
Screen: 1.6 x 1.9" (41 x 48 mm)
Weight 1.32 lbs (600 g) with the batteries
Click here for complete specifications on the AEMC Instruments 404

What's included with the AEMC Instruments 404

  • Clamp-On Meter
  • 2 x Set of Color-Coded Silicone Insulated Test Leads
  • Test Probes
  • Alligator Clips
  • K-Thermocouple with Integrated Adapter
  • Soft Carrying Case
  • 4 x 1.5 V AA Batteries
  • User Manual
  • Limited Three-Year Warranty

Click on a category to view a selection of compatible accessories with the AEMC 404 Clamp-On Meter, 1000 A AC/1500 A DC, temperature.

AEMC 2139.71 Replacement Type-K-Thermocouple Wire Probe, 4 mm integrated adapter 2139.71
For use with the AEMC 401, 403, 601, 603, and 5217.




AEMC 2152.15 Screw-on Test Leads, Colour Coded, Set of 2, 5ft 2152.15
Colour Coded silicone insulated safety leads which have 4mm right-angle banana plugs and 4mm straight screw-on banana plugs. Rated 1000V CAT IV.




AEMC 5000.94 Lead Set with straight banana plugs, 5', 0.15" 5000.94
Compatible with the 404 and 606 clamp meters, this lead set includes two color-coded 5' (1.5 m) silicone leads with 0.15" (4 mm) straight banana plugs. Additionally, these leads safely handle voltages up to 1000 V, are rated CAT-IV, and meet UL V2 standards.




AEMC 2154.74 Leads with Safety Needle Tips, Colour Coded, Set of 2, 5ft 2154.74
Color-coded 5ft lead with safety needle tips (2mm), 1000V CAT IV, 15A. For use with the AEMC 501, 503, 511-514, 565, 5231, 5233, CM605, 670, 675 & F07.




AEMC 2139.72 Soft Carrying Case 2139.72
Replacement Case for use with Clamp-on Meter Models 401, 403, 405, 601, 603 & 606




AEMC 5000.99 Safety Alligator Clip, Black 5000.99
Safety Alligator Clip, Black. Rated 1000V CAT IV, 15A, UL.




AEMC 5100.00 Safety Alligator Clip, Red 5100.00
Safety Alligator Clip, Red. Rated 1000V CAT IV, 15A, UL.




AEMC 5000.98 Probe, 1000 V, red 5000.98
Compatible with the 404 and 606 clamp meters, this red test probe safely handles voltages up to 1000 V and 15 A. In addition, this probe is rated CAT IV and meets UL V2 standards.




AEMC 5000.97 Probe, 1000 V, black 5000.97
Compatible with the 404 and 606 clamp meters, this black test probe safely handles voltages up to 1000 V and 15 A. In addition, this probe is rated CAT IV and meets UL V2 standards.




AEMC 2119.48 Multipurpose Canvas Pouch 2119.48
Multipurpose Pouch for Clamp-on Meters, Clamp-on Ground Testers, and Power Meters Models 8220 & 8230. Dimensions: 11 x 5 x 2.25".




Ask a question about AEMC 404 Clamp-On Meter, 1000 A AC/1500 A DC, temperature

Customer Reviews for the AEMC Instruments 404

AEMC Instruments 404 Offers

Work with fast and accurate electrical measurements with this user-friendly and efficient meter, making it the perfect choice for any commercial or residential project. In addition, this meter features an adapter function, for easy use with external transducers or measurement devices.

Features

  • Large 10,000-count blue electroluminescent backlit display
  • Measures frequency to 20 kHz with 0.1 Hz resolution
  • Current measurement
  • Measurement of Inrush current/overcurrent (True InRush®) with 100 mS capture
  • Voltage measurement
  • Frequency measurement
  • Continuity test with buzzer
  • Resistance measurement
  • Diode test
  • Temperature measurement
  • Adapter function (for use with external transducers/measurement devices)
  • Jaws with centering marks opening up to 1.89" (48 mm)
  • Physical guard
  • Rotary function switch
  • Function buttons
  • Backlit display
  • Input terminals
  • Trigger
  • Battery compartment and compartment screw
  • K-thermocouple with 0.16" (4 mm) integrated adapter
  • 1700 V DC/1200 V AC measurements
  • 1000 V CAT IV/1500 V CAT III safety rated
  • UL94 VI flame retardant self-extinguishing
  • Auto selects AC or DC measurement voltage
  • IP54: This meter is rugged enough for the most demanding work environments and will withstand both dust and water spray, guaranteeing its safety level over time
  • Auto power OFF
  • Hold button
  • Backlight button
  • Min/Max button
  • Relative function
  • Hz button

A range offering unprecedented analytical and diagnostic functions!

TRMS version of Min and Max: The Min and Max are TRMS values calculated over a duration of up to 100 ms. This feature is particularly useful for sizing an installation, the diameter of a power cable, a thermal protection device, etc.

Peak+ and Peak-: Calculated over a period of 1 ms, the Peak+ and Peak- values help to characterize the distortion affecting the signal measured. For example, they may reveal variations in the installation's behavior or even malfunctions.

ΔREL, for quick evaluation: Comparison with a reference quantity is a quick way of evaluating and analyzing your results. A signal's variations can be measured differentially or relatively. The first method indicates the difference between the value of reference and the value measured. The second method indicates the proportion. The ΔRELfunction can be applied to any type of measurement and can be used jointly with the Min, Max and Peak functions

Feature rich clamp-on meter

Ideal tool for any work in the field and is simple to use and groups all the necessary functions in a single, compact solution. Leveraging cutting-edge technology, this meter guarantees top-notch quality while ensuring user-friendly simplicity.

Performance

Benefit from a fast 12-bit TRMS digital acquisition system offering high measurement accuracy. Thanks to it's large bandwidth and high crest factor, this clamp provides accurate measurements whatever the signal type.

Ergonomics

The entire range is designed for one-handed use, even when wearing safety gloves. For maximum efficiency, each measurement corresponds to a specific switch position. The one key, one function concept makes it even easier to use. In addition, this clamp is equipped with automatic detection of the type of signal (AC or DC) on currents, voltages, and power values.

True InRush® function

True InRush® function provides the unique ability to measure power-up events from devices on a network that is already energized. Unlike other instruments which only measure the inrush when the installation is first powered up, our power clamp-on meters measure all types of inrush, even those due to load increases on an installation which is already up and running.

Applications

  • Photovoltaic (PV)
  • Solar panel, inverter testing, comissioning, engineers, and technicians
  • Solar comissioning
  • Low and medium power low voltage locations
  • AC or DC motor testing
  • Electrical power distribution, contractors, and maintenance
  • Commercial, industrial, residential and HVAC/R troubleshooting
  • Safety lighting system maintenance
  • Automotive test troubleshooting
  • Hospitals
  • Field service agencies and technicians
  • Government agencies
  • Educational institutions
  • Plant maintenance personnel
  • Electric utility power quality engineers
  • Railway
  • Lift/elevator technicians
  • Other lift or transport equipment specialists

AEMC Instruments 404 Specifications

DC Voltage Measurement Measurement range: 0 to 99.99 V
Specified measurement range: 0 to 1600 V
Accuracy: 0 to 9.99 V ± (1% R + 10 cts)/10 to 99.99 V ± (1% R + 3 cts)
Resolution: 0.01 V
Input impedance: 10 MΩ

Measurement range: 100 to 999.9 V
Specified measurement range: 0 to 1600 V
Resolution: 0.1 V
Input impedance: 10 MΩ

Measurement range: 1000 to 1700 V1)
Specified measurement range: 0 to 1600 V
Resolution: 1 V
Input impedance: 10 MΩ
1)The display indicates +OL above 3400 V and -OL below - 3400 V, in REL mode. Above 1700 V, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed.
*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct))
AC Voltage Measurement Measurement range: 0.15 to 99.99 V
Specified measurement range2): 0 to 1100 V AC/1600 V peak
Accuracy: 0.15 to 9.99 V ± (1% R+ 10 cts)/10 to 99.99 V ± (1% R + 3cts)
Resolution: 0.01 V
Input impedance: 10 MΩ

100 to 999.9 V
Specified measurement range2): 0 to 1100 V AC/1600 V peak
Accuracy: ± (1% R + 4 cts)
Resolution 0.1 V
Input impedance: 10 MΩ

Measurement range: 1000 to 1200 V RMS/1700 V peak1)
Specified measurement range2): 0 to 1100 V AC/1600 V peak
Accuracy: ± (1% R + 4 cts)
Resolution 1 V
Input impedance: 10 MΩ
1)The display indicates OL above 1700 V. Above 1200 V RMS, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed bandwidth in AC = 3 kHz.
2)Any value between zero and the min threshold of the measurement range (0.15 V) is forced to ---- on the display.
*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct))
DC Current Measurement Measurement range2): 0 to 99.99 A
Specified measurement range: 0 to 100% of the measurement range
Accuracy (zero corrected)2): ± (1% R + 10 cts)
Resolution: 0.01 A

Measurement range: 100 to 999.9 A
Specified measurement range: 0 to 100% of the measurement range
Accuracy (zero corrected)2): (1% R + 3 cts)
Resolution: 0.1 A

Measurement range: 1000 to 1500 A1)
Specified measurement range: 0 to 100% of the measurement range
Accuracy (zero corrected)2):(1.5% R + 3 cts)
Resolution: 1 A
1)The display indicates +OL above 3000 A and -OL below -3000 A in REL mode. The - and + signs are displayed (polarity).
2)The residual current at zero depends on the remanence, it can be corrected by the DC zero function of the HOLD button.
*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct))
AC Current Measurement Measurement range2): 0.25 to 99.99 A
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (1% R + 10 cts)
Resolution: 0.01 A

Measurement range2): 100 to 999.9 A
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (1% R + 3 cts)
Resolution: 0.1 A

Measurement range2): 1000 A (15,000 A peak)1)
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (1% R + 3 cts)
Resolution: 1 A
1)The display indicates OL above 1500 A in PEAK mode. The - and + signs are not displayed. Bandwidth in AC = 2 kHz.
2)In AC, any value between zero and the min. threshold of the measurement range (0.25 A) is forced to show ----on the display
*Accuracy is expressed in ± (x % of the reading (R) + y counts (ct))
True InRush Measurement Measurement range: 10 A to 1000 A AC/10 A to 1500 A DC
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (5% R + 5 cts)
Resolution: 1 A

Peak mode:
Accuracy: Add ± (1.5% R + 0.5 A) to the values above
Peak capture time: 1 ms minimum to 1.5 ms maximum
Continuity Measurement Measurement range: 0 to 999.9 Ω
Open-circuit voltage: ≤3.6 V
Measurement current: 550 μA
Accuracy: ± (1% R + 5 cts)
Buzzer triggering threshold: Adjustable from (1 to 999) Ω (40 Ω is the default)
Resistance Measurement Measurement range1): 0 to 99.9 Ω
Specified measurement range: 1 to 100% of the measurement range
Accuracy: ± (1% R + 10 cts)
Resolution: 0.1 Ω
Open-circuit voltage: ≤3.6 V
Measurement current: 550 μA

Measurement range1): 100 to 999.9 Ω
Specified measurement range: 1 to 100% of the measurement range
Accuracy: ± (1% R + 5 cts)
Resolution: 0.1 Ω
Open-circuit voltage: ≤3.6 V
Measurement current: 500 μA

Measurement range1): 10 to 9999 kΩ
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (1% R + 5 cts)
Resolution: 1 Ω
Open-circuit voltage: ≤3.6 V
Measurement current: 100 μA

Measurement range1): 10 to 99.99 kΩ
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ± (1% R + 5 cts)
Resolution: 10 Ω
Open-circuit voltage: ≤3.6 V
Measurement current: 10 μA

MAX/MIN mode:
Accuracy: add 1% R to the values above
Capture of the extreme: Approximately 100 ms
1)Above the maximum display value, the display unit indicates OL. The - and + signs are not displayed.
Diode Test Measurement range: 0 to 3.199 V DC
Specified measurement range: 1 to 100% of the measurement range
Accuracy: ± (1% R + 10 cts)
Resolution: 0.001 V
Measurement current: 0.55 mA
Indication (junction reversed or open circuit): OL is displayed when the measured voltage >3.199 V
Frequency Voltage Measurement Measurement range1): 5 to 999.9 Hz
Specified measurement range: 1 to 100% of the measurement range
Accuracy: ±0.4% R + 1 ct
Resolution: 0.1 Hz

Measurement range1): 1000 to 9999 hZ
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ±0.4% R + 1 ct
Resolution: 1 Hz

Measurement range1): 10 to 19.99 kHz
Specified measurement range: 0 to 100% of the measurement range
Accuracy: ±0.4% R + 1 ct
Resolution: 10 Hz

MAX/MIN mode (from 10 Hz to 1 kHz) for voltage and current: Accuracy: Add 1% R to the values above
Capture time of the extreme: Approximately 100 ms
1)In MAX/MIN mode, the operating range is limited to 1 kHz. If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays ----
Frequency Current Measurement Measurement range1): 5 to 999.9 Hz
Specified measurement range: 1 to 100% of the measurement range
Accuracy: ± 0.4% R + 1 ct
Resolution: 0.1 Hz

MAX/MIN mode (from 10 Hz to 1 kHz) for voltage and current: Accuracy: Add 1% R to the values above
Capture time of the extreme: Approximately 100 ms
1)In MAX/MIN mode, the operating range is limited to 1 kHz. If the level of the signal is too low (U <3 V or I <3 A) or if the frequency is less than 5 Hz, the device cannot determine the frequency and displays ----
Temperature Measurement Type of sensor K-thermocouple
Measurement range: 76 to 1831.8°F (-60 to 999.9°C)/1832 to 2192°F (1000 to 1200°C)
Specified measurement range: 1 to 100% of the measurement range
Accuracy1): 1% R ±5.4°F (1% R ±3°C)
Resolution: 0.1°F (0.1°C)

MAX/MIN mode (10 Hz to 1 kHz):
Accuracy: Add 1% R to the values above
Capture time of the extreme: Approximately 100 ms
1)The stated external temperature measurement accuracy does not take the accuracy of the K-thermocouple into account.
*NOTE: Use of the thermal time constant (0.7 min/°C): If there is a sudden variation of the temperature of the clamp, by 50°F (10°C) for example, the clamp will be at 99% (cnst = 5) of the final temperature after 0.7 min/°C x 5 to 35 min (the time constant of the external sensor must be added to this value).
Adapter Function Measurement in DC Mode Measurement range1): 0 to 999.9 mV
Specified measurement range2): 0 to 100% of the measurement range
Accuracy: 1% R + 3 cts
Resolution: 0.1 mV
Input impedance: 10 MΩ

Measurement range1): 1 to 9.99 V
Specified measurement range2): 0 to 100% of the measurement range
Accuracy: 1% R + 3 cts
Resolution: 10 mV
Input impedance: 10 MΩ

MAX/MIN mode (from 10 Hz to 1 kHz): Accuracy: Add 1% R to the values above
Capture of the extreme: Approximately 100 ms
1)The basic display is 10,000 counts. The position of the decimal count and the display of multiples (m and k) depend on the programming of the scale factor. -In DC, the display indicates +OL above +9999 counts and -OL below -9999 counts. The - and + signs are displayed (polarity). -In AC, the display indicates OL above 9999 counts.
2)The maximum bandwidth is 1 kHz.
Adapter Function Measurement in AC Mode Measurement range1): 5 to 999.9 mV
Specified measurement range2): 0 to 100% of the measurement range
Accuracy: 5 to 99.9 mV ± 1% R + 10 cts/100 to 999.9 mV ± 1% R + 3 cts
Resolution: 0.1 mV
Input impedance: 10 MΩ

Measurement range1): 1 to 9.99 V
Specified measurement range2): 0 to 100% of the measurement range
Accuracy: 1% R + 3 cts
Resolution: 10 mV
Input impedance: 10 MΩ

MAX/MIN mode (from 10 Hz to 1 kHz): Accuracy: Add 1% R to the values above
Capture of the extreme: Approximately 100 ms
1)The basic display is 10,000 counts. The position of the decimal count and the display of multiples (m and k) depend on the programming of the scale factor. -In DC, the display indicates +OL above +9999 counts and -OL below -9999 counts. The - and + signs are displayed (polarity). -In AC, the display indicates OL above 9999 counts.
2)The maximum bandwidth is 1 kHz.
Screen LCD unit
Blue backlighting
Temperature Operating: -4 to 131°F (-20 to 55°C)
Storage: -40 to 158°F (-40 to 70°C)
Relative Humidity (RH) Operating: ≤90% up to 131°F (55°C)
Storage: ≤90% up to 158°F (70°C)
Power Supply Batteries: 4 x 1.5 V AA LR6
Battery life: >350 hours (without backlighting)
Auto power off: After 10 minutes with no switch and/or button activity
Compliance with International Standards Electric safety: Compliant with standards IEC/EN 61010-1 or BS EN 61010-1, IEC/EN 61010-2-032 or BS EN 61010-2-032: 1000 V CAT IV and 1500 V CAT III
Electromagnetic compatibility: Compliant with standard EN-61326-1 or BS EN 61326-1, classification: residential environment
Mechanical strength: Free fall: 3.28' (2 m), in accordance with standard IEC-68-2-32
Level of protection: Housing IP54 (per standard IEC-60529)/Jaws: IP40
Housing Rigid polycarbonate shell with over-molded elastomer covering; UL94 V1
Jaws Polycarbonate
Opening: 1.9" (48 mm)
Clamping diameter: 1.9" (48 mm)
Dimensions 10.7 x 3.6 x 1.6" (272 x 92 x 41 mm)
Screen: 1.6 x 1.9" (41 x 48 mm)
Weight 1.32 lbs (600 g) with the batteries
Click here for complete specifications on the AEMC Instruments 404

What's included with the AEMC Instruments 404

  • Clamp-On Meter
  • 2 x Set of Color-Coded Silicone Insulated Test Leads
  • Test Probes
  • Alligator Clips
  • K-Thermocouple with Integrated Adapter
  • Soft Carrying Case
  • 4 x 1.5 V AA Batteries
  • User Manual
  • Limited Three-Year Warranty

Click on a category to view a selection of compatible accessories with the AEMC 404 Clamp-On Meter, 1000 A AC/1500 A DC, temperature.

AEMC 2139.71 Replacement Type-K-Thermocouple Wire Probe, 4 mm integrated adapter 2139.71
For use with the AEMC 401, 403, 601, 603, and 5217.




AEMC 2152.15 Screw-on Test Leads, Colour Coded, Set of 2, 5ft 2152.15
Colour Coded silicone insulated safety leads which have 4mm right-angle banana plugs and 4mm straight screw-on banana plugs. Rated 1000V CAT IV.




AEMC 5000.94 Lead Set with straight banana plugs, 5', 0.15" 5000.94
Compatible with the 404 and 606 clamp meters, this lead set includes two color-coded 5' (1.5 m) silicone leads with 0.15" (4 mm) straight banana plugs. Additionally, these leads safely handle voltages up to 1000 V, are rated CAT-IV, and meet UL V2 standards.




AEMC 2154.74 Leads with Safety Needle Tips, Colour Coded, Set of 2, 5ft 2154.74
Color-coded 5ft lead with safety needle tips (2mm), 1000V CAT IV, 15A. For use with the AEMC 501, 503, 511-514, 565, 5231, 5233, CM605, 670, 675 & F07.




AEMC 2139.72 Soft Carrying Case 2139.72
Replacement Case for use with Clamp-on Meter Models 401, 403, 405, 601, 603 & 606




AEMC 5000.99 Safety Alligator Clip, Black 5000.99
Safety Alligator Clip, Black. Rated 1000V CAT IV, 15A, UL.




AEMC 5100.00 Safety Alligator Clip, Red 5100.00
Safety Alligator Clip, Red. Rated 1000V CAT IV, 15A, UL.




AEMC 5000.98 Probe, 1000 V, red 5000.98
Compatible with the 404 and 606 clamp meters, this red test probe safely handles voltages up to 1000 V and 15 A. In addition, this probe is rated CAT IV and meets UL V2 standards.




AEMC 5000.97 Probe, 1000 V, black 5000.97
Compatible with the 404 and 606 clamp meters, this black test probe safely handles voltages up to 1000 V and 15 A. In addition, this probe is rated CAT IV and meets UL V2 standards.




AEMC 2119.48 Multipurpose Canvas Pouch 2119.48
Multipurpose Pouch for Clamp-on Meters, Clamp-on Ground Testers, and Power Meters Models 8220 & 8230. Dimensions: 11 x 5 x 2.25".




Ask a question about AEMC 404 Clamp-On Meter, 1000 A AC/1500 A DC, temperature

Customer Reviews for the AEMC Instruments 404

More AEMC Instruments Products