Additel ADT875-155-G-110V Dry Well Calibrator, -40 to 155°C, insert G, 110V

Model: ADT875-155-G-110V

Additel ADT875-155-G-110V Dry Well Calibrator, -40 to 155°C, insert G, 110V

Model: ADT875-155-G-110V

Bringing a repeatable temperature source to the plant floor, this dry well calibrator spans -40 to 155°C, holds ±0.18°C across the full range, and reaches 155°C in 13 minutes. Insert G sets the hole pattern in the well. Auto step, ramp and soak run from the 6.5 in touch screen, with Wi-Fi and Ethernet for remote control.

Bringing a repeatable temperature source to the plant floor, this dry well calibrator spans -40 to 155°C, holds ±0.18°C across the full range, and reaches 155°C in 13 minutes. Insert G sets the hole pattern in the well. Auto step, ramp and soak run from the 6.5 in touch screen, with Wi-Fi and Ethernet for remote control.

Your Price $13702.00 CAD
Availability 2 to 3 Weeks
Quantity

Additel ADT875-155-G-110V Offers

Features

  • Interchangeable metal insert sets the hole pattern, so one well serves many sensor diameters
  • Removable insert lifts out with the supplied tool while the well is still warm
  • 6.5" color touch screen drives set point, auto step, ramp and soak without a PC
  • Reaches 155°C in 13 minutes
  • USB, Ethernet, Wi-Fi and Bluetooth allow remote control and data download
  • Eight display languages including English, French and Spanish

Applications

  • Plant technicians carrying a temperature source to the instrument rather than pulling the instrument to the shop
  • Instrument technicians verifying process temperature transmitters on site
  • Calibration laboratories issuing accredited temperature certificates
  • Maintenance teams meeting scheduled recalibration intervals
  • Oil, gas and chemical facilities checking RTDs and thermocouples in the field

Additel ADT875-155-G-110V Specifications

Temperature Performance
Temperature Range at 23°C -40 to 155°C
Display Accuracy ±0.18°C at full range
Stability ±0.01°C at full range
Axial Uniformity at 60 mm (2.4") ±0.07°C at full range
Radial Uniformity ±0.01°C at full range
Loading Effect ±0.1°C display sensor, ±0.02°C external sensor
Hysteresis 0.025°C (display sensor)
Resolution 0.01°C
Temperature Units °C, °F and K
Heating Time 13 minutes from -40 to 155°C, 5 minutes from -40 to 23°C, 8 minutes from 23 to 155°C
Cooling Time 28 minutes from 155 to -40°C, 8 minutes from 155 to 23°C, 20 minutes from 23 to -40°C
Typical Time to Stability 10 minutes
Well and Insert
Immersion Depth 5.70" (145 mm)
Insert Outside Diameter 1.02" (25.8 mm)
Insert Supplied ADT110-875-L-INSERT-G
General
Display 6.5" (165 mm) color touch screen
Communication USB-A, USB-B, RJ45, Wi-Fi, Bluetooth
Dimensions 12.6 x 6.7 x 13.0" (320 x 170 x 330 mm)
Weight 21.8 lb (9.9 kg)
Power Requirements 90 to 254 V AC, 45 to 65 Hz, 580 W
Environmental Conditions 8 to 38°C for guaranteed accuracy, 0 to 50°C operating, 0% to 90% RH non-condensing, to 3000 m
Storage Conditions -20 to 60°C
Mechanical Testing Vibration 2 g (10 to 500 Hz) for 30 minutes on 2 sides; impact 4 g three times; drop test 19.6" (500 mm)
Click here for complete specifications on the Additel ADT875-155-G-110V

What's included with the Additel ADT875-155-G-110V

  • Dry Well Calibrator
  • ISO 17025 Accredited Calibration Certificate
  • Insert, 1 selected
  • Insert Removal Tool
  • Silica Gel Plugs, 1 set of 3
  • Insulation Plug
  • Power Cable
  • USB Cable
  • One-Year Warranty

Ask a question about Additel ADT875-155-G-110V Dry Well Calibrator, -40 to 155°C, insert G, 110V

Customer Reviews for the Additel ADT875-155-G-110V

Additel ADT875-155-G-110V Offers

Features

  • Interchangeable metal insert sets the hole pattern, so one well serves many sensor diameters
  • Removable insert lifts out with the supplied tool while the well is still warm
  • 6.5" color touch screen drives set point, auto step, ramp and soak without a PC
  • Reaches 155°C in 13 minutes
  • USB, Ethernet, Wi-Fi and Bluetooth allow remote control and data download
  • Eight display languages including English, French and Spanish

Applications

  • Plant technicians carrying a temperature source to the instrument rather than pulling the instrument to the shop
  • Instrument technicians verifying process temperature transmitters on site
  • Calibration laboratories issuing accredited temperature certificates
  • Maintenance teams meeting scheduled recalibration intervals
  • Oil, gas and chemical facilities checking RTDs and thermocouples in the field

Additel ADT875-155-G-110V Specifications

Temperature Performance
Temperature Range at 23°C -40 to 155°C
Display Accuracy ±0.18°C at full range
Stability ±0.01°C at full range
Axial Uniformity at 60 mm (2.4") ±0.07°C at full range
Radial Uniformity ±0.01°C at full range
Loading Effect ±0.1°C display sensor, ±0.02°C external sensor
Hysteresis 0.025°C (display sensor)
Resolution 0.01°C
Temperature Units °C, °F and K
Heating Time 13 minutes from -40 to 155°C, 5 minutes from -40 to 23°C, 8 minutes from 23 to 155°C
Cooling Time 28 minutes from 155 to -40°C, 8 minutes from 155 to 23°C, 20 minutes from 23 to -40°C
Typical Time to Stability 10 minutes
Well and Insert
Immersion Depth 5.70" (145 mm)
Insert Outside Diameter 1.02" (25.8 mm)
Insert Supplied ADT110-875-L-INSERT-G
General
Display 6.5" (165 mm) color touch screen
Communication USB-A, USB-B, RJ45, Wi-Fi, Bluetooth
Dimensions 12.6 x 6.7 x 13.0" (320 x 170 x 330 mm)
Weight 21.8 lb (9.9 kg)
Power Requirements 90 to 254 V AC, 45 to 65 Hz, 580 W
Environmental Conditions 8 to 38°C for guaranteed accuracy, 0 to 50°C operating, 0% to 90% RH non-condensing, to 3000 m
Storage Conditions -20 to 60°C
Mechanical Testing Vibration 2 g (10 to 500 Hz) for 30 minutes on 2 sides; impact 4 g three times; drop test 19.6" (500 mm)
Click here for complete specifications on the Additel ADT875-155-G-110V

What's included with the Additel ADT875-155-G-110V

  • Dry Well Calibrator
  • ISO 17025 Accredited Calibration Certificate
  • Insert, 1 selected
  • Insert Removal Tool
  • Silica Gel Plugs, 1 set of 3
  • Insulation Plug
  • Power Cable
  • USB Cable
  • One-Year Warranty

Ask a question about Additel ADT875-155-G-110V Dry Well Calibrator, -40 to 155°C, insert G, 110V

Customer Reviews for the Additel ADT875-155-G-110V

More Additel Products