ACI AFS-460-DSS Differential Pressure Switch, 1.25 to 12 inWC, dual SPST

Model: AFS-460-DSS | Order No: 101792/A

ACI AFS-460-DSS Differential Pressure Switch, 1.25 to 12 inWC, dual SPST

Model: AFS-460-DSS | Order No: 101792/A

Proving air flow where two independent circuits must be interlocked, this differential pressure switch trips between 1.25 and 12 inWC and drives dual SPST normally closed contacts. Manual reset keeps the fault latched until an operator clears it, so a momentary loss of flow cannot silently restore the system.

Proving air flow where two independent circuits must be interlocked, this differential pressure switch trips between 1.25 and 12 inWC and drives dual SPST normally closed contacts. Manual reset keeps the fault latched until an operator clears it, so a momentary loss of flow cannot silently restore the system.

Sale Price $361.58 CAD
Regular Price $404.00 CAD
Availability 2 to 3 Weeks
Quantity

ACI AFS-460-DSS Offers

The Model AFS-460-DSS is a general purpose airflow proving switch designed for 120 VAC HVAC and Energy Management applications where dual manual reset switches with SPST contacts are needed. It may be used to sense positive, negative, or differential air pressure. The plated housing contains a diaphragm, a calibration spring, and 2 snap-acting switches with a single manual reset button. An enclosure cover guards against accidental contact with the live switch terminal screws and the set point adjusting screw.

Features

  • Dual SPST normally closed contacts for two independent interlock circuits
  • Manual reset latches the fault until an operator clears it
  • Snap-acting contacts on a diaphragm actuator

Applications

  • Monitoring filter blockage
  • Proof of flow
  • Prove excessive or insufficient flow
  • Alarms and control

ACI AFS-460-DSS Specifications

Input Pressure Range 1.25 ± 0.06"w.c. to 12.0"w.c. (31.8mm ±1.52mm w.c. to 305 mm w.c.)
Measured Media Air, or combustion by-products that will not degrade silicone
Pressure Range 1.25 to 12 inWC
Set Point Range, Input Pressure Range 1.25 ± 0.06"w.c. to 12.0"w.c. (31.8mm ±1.52mm w.c. to 305 mm w.c.)
Contact (Load) Rating @ 60 Hz.,15 amp 125, 250, or 277 v AC | 1/4 hp 125 v AC, 1/2Hp 250 V AC 1/2 amp 125 v DC, 1/4 amp 250 v DC | 0.5 VA @ 24 v AC, 50/60 Hz
Contact Arrangement 2 SPST-NC Lead/Lag (manual reset)
Contact Type Dual SPST
Electrical Connections Screw top terminals with cup washers
Sample Line Connections Connectors will accept 1/4" (6.35mm) OD rigid or semi-rigid tubing
Conduit Opening 7/8" diameter opening accepts 1/2" conduit
Field Adjustable "Operate" Range 1.31"w.c. to 12.0" w.c.
Life Expectancy Exceeds UL-recognized mechanical endurance test of 6,000 cycles minimum at 0.5 psi (0.03 bar, 3.45 kPa) maximum pressure each cycle and at maximum electrical load
Maximum Pressure 1/2 psi (0.03 bar; 3.45 kPa)
Operating Humidity Range 10 to 95% RH, non-condensing
Operating Temperature Range -40 to 180°F (-40 to 82°C)
Enclosure Material Galvanized Steel
Mounting Direction Mount with the diaphragm in any vertical plane
Product Dimensions (L x W x H) 6.15 x 4.35 x 3.50" (156.2 x 110.5 x 88.9 mm)
Product Weight 1.10 lbs (501 g)
Agency Approvals UL & CSA approved; CE pending
Click here for complete specifications on the ACI AFS-460-DSS

What's included with the ACI AFS-460-DSS

  • Differential Pressure Switch
  • Two-Year Warranty

Ask a question about ACI AFS-460-DSS Differential Pressure Switch, 1.25 to 12 inWC, dual SPST

Customer Reviews for the ACI AFS-460-DSS

ACI AFS-460-DSS Offers

The Model AFS-460-DSS is a general purpose airflow proving switch designed for 120 VAC HVAC and Energy Management applications where dual manual reset switches with SPST contacts are needed. It may be used to sense positive, negative, or differential air pressure. The plated housing contains a diaphragm, a calibration spring, and 2 snap-acting switches with a single manual reset button. An enclosure cover guards against accidental contact with the live switch terminal screws and the set point adjusting screw.

Features

  • Dual SPST normally closed contacts for two independent interlock circuits
  • Manual reset latches the fault until an operator clears it
  • Snap-acting contacts on a diaphragm actuator

Applications

  • Monitoring filter blockage
  • Proof of flow
  • Prove excessive or insufficient flow
  • Alarms and control

ACI AFS-460-DSS Specifications

Input Pressure Range 1.25 ± 0.06"w.c. to 12.0"w.c. (31.8mm ±1.52mm w.c. to 305 mm w.c.)
Measured Media Air, or combustion by-products that will not degrade silicone
Pressure Range 1.25 to 12 inWC
Set Point Range, Input Pressure Range 1.25 ± 0.06"w.c. to 12.0"w.c. (31.8mm ±1.52mm w.c. to 305 mm w.c.)
Contact (Load) Rating @ 60 Hz.,15 amp 125, 250, or 277 v AC | 1/4 hp 125 v AC, 1/2Hp 250 V AC 1/2 amp 125 v DC, 1/4 amp 250 v DC | 0.5 VA @ 24 v AC, 50/60 Hz
Contact Arrangement 2 SPST-NC Lead/Lag (manual reset)
Contact Type Dual SPST
Electrical Connections Screw top terminals with cup washers
Sample Line Connections Connectors will accept 1/4" (6.35mm) OD rigid or semi-rigid tubing
Conduit Opening 7/8" diameter opening accepts 1/2" conduit
Field Adjustable "Operate" Range 1.31"w.c. to 12.0" w.c.
Life Expectancy Exceeds UL-recognized mechanical endurance test of 6,000 cycles minimum at 0.5 psi (0.03 bar, 3.45 kPa) maximum pressure each cycle and at maximum electrical load
Maximum Pressure 1/2 psi (0.03 bar; 3.45 kPa)
Operating Humidity Range 10 to 95% RH, non-condensing
Operating Temperature Range -40 to 180°F (-40 to 82°C)
Enclosure Material Galvanized Steel
Mounting Direction Mount with the diaphragm in any vertical plane
Product Dimensions (L x W x H) 6.15 x 4.35 x 3.50" (156.2 x 110.5 x 88.9 mm)
Product Weight 1.10 lbs (501 g)
Agency Approvals UL & CSA approved; CE pending
Click here for complete specifications on the ACI AFS-460-DSS

What's included with the ACI AFS-460-DSS

  • Differential Pressure Switch
  • Two-Year Warranty

Ask a question about ACI AFS-460-DSS Differential Pressure Switch, 1.25 to 12 inWC, dual SPST

Customer Reviews for the ACI AFS-460-DSS

More ACI Products