This wall-mounted relative humidity and temperature transmitter uses energy-efficient digital polymer sensing technology to provide precise RH measurements. Additionally, the transmitter comes included with a 20 kΩ thermistor, and an RH output of 4 to 20 mA with ±2% accuracy.
This wall-mounted relative humidity and temperature transmitter uses energy-efficient digital polymer sensing technology to provide precise RH measurements. Additionally, the transmitter comes included with a 20 kΩ thermistor, and an RH output of 4 to 20 mA with ±2% accuracy.
The AcuHUM RM series room mount relative humidity (RH) sensor utilizes advanced digital polymer sensing technology to provide highly precise RH measurement, reduce power consumption, and improve long-term stability. The RH sensor features an optional thermistor, RTD, or transmitter to provide temperature and RH signals in one device. The AcuHUM RM is designed to be wall-mounted indoors with a four-way aspiration enclosure design to minimize self-heating. It can be ordered with an optional LCD to display humidity and temperature in one device.
A room mount RH and temperature sensor is specifically built to measure relative humidity and temperature from an indoor space as an integral part of a building automation system. RH sensors are elegantly designed to seamlessly blend in with rooms such as offices, labs, hospitals, and schools to help improve indoor air quality, health, safety, and comfort. The RH sensor accurately tracks room humidity and temperature level using digital polymer sensor technology and provides output to building automation systems to control HVAC/R equipment.
Features
Applications
Indoor Humidity & Temperature
The AcuHUM RM is designed to be mounted onto a flat surface, perfect for room applications such as monitoring humidity/temperature fluctuations in offices, labs, hospitals, and more. With ±2% accuracy on relative humidity and up to 0.2°C (0.36°F) accuracy on temperature measurements, AcuHUM RM delivers precise data that helps the building automation system decide whether to heat, cool, humidify, or dehumidify the room.
Optimize Energy Usage
By accurately measuring the room humidity and temperature level, the AcuHUM RM gives building automation systems the ability to make fine adjustments, avoid overcooling or overheating, enable demand-based ventilation, process control and optimize energy usage.
Indoor Air Quality (IAQ)
Humidity and temperature are important metrics for indoor air quality. When these parameters are not maintained at the proper level, it may lead to discomfort, stress, and even health issues. AcuHUM RM monitors both parameters to ensure a healthier indoor environment.
| Specifications for the AcuHUM-RM-A-A-03-C | |
| RH Analog Output | 4 to 20 mA transmitter |
| Temperature Output | Resistive Output |
| Temperature Sensor | 20KΩ Thermistor |
| Sensor Accuracy | ±0.2°C at 25°C (0.36°F at 77°F) |
| Electrical (RH) | |
| Voltage Power | 16 to 28 V AC / 16 to 35 V DC |
| Current Power | 18.5 to 35 V DC (RL=500Ω) 8.5 to 35 V DC (RL=0Ω) |
| Output | 4 to 20 mA (2 Wires) or 0 to 10 V DC (3 Wires) |
| Relative Humidity Performance | |
| RH Sensor Type | Digital Polymer |
| Accuracy | ±2% (25°C, 20 to 80% RH) |
| Measurement RH Range | 0 to 100% |
| Operating RH Range | 5 to 95% RH (non-condensing) |
| Hysteresis | <±1% RH |
| Response Time | <10s (25°C, in Slow Air) |
| Drift | <±0.5% RH per year |
| Electrical (Temperature) | |
| Transmitter Voltage Power | 16 to 28 V AC / 16 to 35 V DC |
| Transmitter Current Power | 18.5 to 35 V DC (RL=500Ω) 8.5 to 35 V DC (RL=0Ω) |
| Transmitter Output | 4 to 20 mA (2 Wires) or 0 to 10 V DC (3 Wires) |
| Output Load | ≤500Ω (Current), ≥2KΩ (Voltage) |
| Temperature Performance | |
| Temperature Sensor Type | RTD or thermistor, see ordering information |
| Temperature Transmitter Measurement Range | 32 to 122°F (0 to 50°C) |
| Response Time | <10 s |
| Environmental | |
| Operating Temperature Range | -4 to 158°F (-20 to 70°C) |
| Storage Temperature | -4 to 176°F (-20 to 80°C) |
| Mechanical | |
| Mounting | Single Gang Junction Box or Surface Mount |
| Wiring Connection | Screw Terminal Blocks |
| Weight | 0.24 lbs (110 g) |
| Certifications and Warranty | |
| Enclosure Material | Fire retardant polycarbonate (UL94V-0) |
| Protection | IP30 |
| Agency Approvals | CE |
| Warranty | 5 Years |
| Specifications for the AcuHUM-RM-A-A-03-C | |
| RH Analog Output | 4 to 20 mA transmitter |
| Temperature Output | Resistive Output |
| Temperature Sensor | 20KΩ Thermistor |
| Sensor Accuracy | ±0.2°C at 25°C (0.36°F at 77°F) |
| Electrical (RH) | |
| Voltage Power | 16 to 28 V AC / 16 to 35 V DC |
| Current Power | 18.5 to 35 V DC (RL=500Ω) 8.5 to 35 V DC (RL=0Ω) |
| Output | 4 to 20 mA (2 Wires) or 0 to 10 V DC (3 Wires) |
| Relative Humidity Performance | |
| RH Sensor Type | Digital Polymer |
| Accuracy | ±2% (25°C, 20 to 80% RH) |
| Measurement RH Range | 0 to 100% |
| Operating RH Range | 5 to 95% RH (non-condensing) |
| Hysteresis | <±1% RH |
| Response Time | <10s (25°C, in Slow Air) |
| Drift | <±0.5% RH per year |
| Electrical (Temperature) | |
| Transmitter Voltage Power | 16 to 28 V AC / 16 to 35 V DC |
| Transmitter Current Power | 18.5 to 35 V DC (RL=500Ω) 8.5 to 35 V DC (RL=0Ω) |
| Transmitter Output | 4 to 20 mA (2 Wires) or 0 to 10 V DC (3 Wires) |
| Output Load | ≤500Ω (Current), ≥2KΩ (Voltage) |
| Temperature Performance | |
| Temperature Sensor Type | RTD or thermistor, see ordering information |
| Temperature Transmitter Measurement Range | 32 to 122°F (0 to 50°C) |
| Response Time | <10 s |
| Environmental | |
| Operating Temperature Range | -4 to 158°F (-20 to 70°C) |
| Storage Temperature | -4 to 176°F (-20 to 80°C) |
| Mechanical | |
| Mounting | Single Gang Junction Box or Surface Mount |
| Wiring Connection | Screw Terminal Blocks |
| Weight | 0.24 lbs (110 g) |
| Certifications and Warranty | |
| Enclosure Material | Fire retardant polycarbonate (UL94V-0) |
| Protection | IP30 |
| Agency Approvals | CE |
| Warranty | 5 Years |