Works at a fast sampling rate for high-performance indication and reaction to fast processes dynamics, this universal input panel meter with two relays has six digits for high-resolution variables with 0.67" (17 mm) height display. Provide a clear view, easy to read and diagnose from a distance.
Works at a fast sampling rate for high-performance indication and reaction to fast processes dynamics, this universal input panel meter with two relays has six digits for high-resolution variables with 0.67" (17 mm) height display. Provide a clear view, easy to read and diagnose from a distance.
Electronic robustness and anti-flame material enclosure comply with the main world-class approvals for industry devices.
Features
Features
Applications
| Display | 7-segment LED, 6-digit with 0.67" (17 mm) height |
| Input Type | Thermocouples J, K, T, N, R, S, B, E, Pt100, 0 to 20 mA, 4 to 20 mA, 0 to 50 mV, 0 to 5 V DC, 0 to 10 V DC, 4 to 20 mA no linear, 0 to 20 mA custom linear, 4 to 20 mA custom linear, 0 to 20 mA custom no linear, 4 to 20 mA custom no linear. |
| Accuracy | Thermocouples J, K, T: 0.25% of span ±33.8°F (1°C) Thermocouples N, R, S, B: 0.25% of span ±37.4°F (3°C) Pt100, 0 to 20 mA, 4 to 20 mA, 0 to 5 V DC, 0 to 10 V DC: 0.2% of the span |
| Sampling Rate | 5 samples per second for Pt100 and thermocouples 15 samples per second for 0 to 50 mV, 4 to 20 mA, 0 to 5 V and 0 to 10 V |
| Display Resolution | Temperature: 1 / 0.1 Other measures: 1 / 0.1 / 0.01 / 0.001 / 0.0001 |
| Custom Linearization | 30 points for non-standard sensors |
| Digital Input | Operates as a key for Hold, Peak Hold and maximum/minimum reset |
| Analog Output | 0 to 20 mA or 4 to 20 mA (optional) - electrically isolated |
| Alarms | Up to 4 alarms |
| Communication | RS485 Modbus RTU optional |
| Safety | Password protected configuration |
| Configuration Interface | Via RS485 |
| Power Supply | 100 to 240 V AC / DC or 12 to 24 V DC |
| Enclosure | IP20; ABS + PC UL94 V-0 |
| Dimensions | 3.78 x 1.89 x 3.62" (96 x 48 x 92 mm) (⅛ DIN) |
| Display | 7-segment LED, 6-digit with 0.67" (17 mm) height |
| Input Type | Thermocouples J, K, T, N, R, S, B, E, Pt100, 0 to 20 mA, 4 to 20 mA, 0 to 50 mV, 0 to 5 V DC, 0 to 10 V DC, 4 to 20 mA no linear, 0 to 20 mA custom linear, 4 to 20 mA custom linear, 0 to 20 mA custom no linear, 4 to 20 mA custom no linear. |
| Accuracy | Thermocouples J, K, T: 0.25% of span ±33.8°F (1°C) Thermocouples N, R, S, B: 0.25% of span ±37.4°F (3°C) Pt100, 0 to 20 mA, 4 to 20 mA, 0 to 5 V DC, 0 to 10 V DC: 0.2% of the span |
| Sampling Rate | 5 samples per second for Pt100 and thermocouples 15 samples per second for 0 to 50 mV, 4 to 20 mA, 0 to 5 V and 0 to 10 V |
| Display Resolution | Temperature: 1 / 0.1 Other measures: 1 / 0.1 / 0.01 / 0.001 / 0.0001 |
| Custom Linearization | 30 points for non-standard sensors |
| Digital Input | Operates as a key for Hold, Peak Hold and maximum/minimum reset |
| Analog Output | 0 to 20 mA or 4 to 20 mA (optional) - electrically isolated |
| Alarms | Up to 4 alarms |
| Communication | RS485 Modbus RTU optional |
| Safety | Password protected configuration |
| Configuration Interface | Via RS485 |
| Power Supply | 100 to 240 V AC / DC or 12 to 24 V DC |
| Enclosure | IP20; ABS + PC UL94 V-0 |
| Dimensions | 3.78 x 1.89 x 3.62" (96 x 48 x 92 mm) (⅛ DIN) |