Upgradeable industrial emissions analyser with heavy duty pump.
Upgradeable industrial emissions analyser with heavy duty pump.
Upgradeable industrial analyzer perfect for installation, commissioning and servicing of industrial/commercial oil, gas or biomass appliances.
Features
Applications
| Temperature | |
| Flue Temperature | Resolution: 0.1°C/F Accuracy: ±2.0°C ±0.3% Reading, ±1°C ±0.3% Reading Range: 32 to 2200°F (0 to 1200°C) with suitable probe |
| Oxygen | |
| Resolution | 0.1% |
| Accuracy | ±0.2% |
| Range | 0 to 25% |
| Carbon Monoxide | |
| Resolution | 1 ppm |
| Accuracy | ±20 ppm <400 ppm<br> ±5% <5000 ppm<br> ±10% >5000 ppm |
| Range | 0 to 100,000 ppm |
| General Specifications | |
| Ambient Operating Range | 23 to 122°F (-5 to 50°C) 10 to 90% RH non-condensing |
| Battery Life | >8 Hours from full charge |
Click on a category to view a selection of compatible accessories with the Kane KANE945 Combustion Analyzer with O2, CO, PRSR.
| Temperature | |
| Flue Temperature | Resolution: 0.1°C/F Accuracy: ±2.0°C ±0.3% Reading, ±1°C ±0.3% Reading Range: 32 to 2200°F (0 to 1200°C) with suitable probe |
| Oxygen | |
| Resolution | 0.1% |
| Accuracy | ±0.2% |
| Range | 0 to 25% |
| Carbon Monoxide | |
| Resolution | 1 ppm |
| Accuracy | ±20 ppm <400 ppm<br> ±5% <5000 ppm<br> ±10% >5000 ppm |
| Range | 0 to 100,000 ppm |
| General Specifications | |
| Ambient Operating Range | 23 to 122°F (-5 to 50°C) 10 to 90% RH non-condensing |
| Battery Life | >8 Hours from full charge |
Click on a category to view a selection of compatible accessories with the Kane KANE945 Combustion Analyzer with O2, CO, PRSR.