Record temperature in up to eight different locations simultaneously with this data logger. Additionally, this logger features eight channels.
Record temperature in up to eight different locations simultaneously with this data logger. Additionally, this logger features eight channels.
Features
Applications
Sensor Specifications | |
Type | NTC Thermistor - 10,000 Ω at 77°F (25°C) |
Range | -40 to 158°F (-40 to 70°C) |
Accuracy | ±0.3°F over the range of 32 to 158°F (±0.2 over the range of 0 to 70°C) |
Resolution | 0.05°F (0.03°C) at 25°C Better than 0.12°F (0.07°C) between -13 and 158°F (-25 and 70°C) Better than 0.23°F (0.13°C) between -40 and -13°F (-40 and -25°C) |
General Specifications | |
Number of Channels | Eight |
Sampling Rates | User selectable rates from 25 per second to once every eight hours |
Memory Size | 32 KB 128 KB |
Software Requirements | TrendReader® Standard 2 |
PC Requirements | IBM PC or 100% compatible with at least one free serial port 2 MB of RAM memory 2 MB of hard disk space |
Operating Limits | -40 to 158°F (-40 to 70°C) and 0 to 95% RH (non-condensing) |
Sampling Methods | Continuous (First-in, first-out) Stop when full (Fill-then-stop) |
Clock Accuracy | ±2 seconds per day |
Mounting | Magnetic backing or locking eyelet |
Resolution | 12-bit (1 part in 4096) |
Battery | 3.6 V Lithium |
Case Material | Noryl® plastic |
Dimensions | 4.2 x 2.9 x 0.9" (107 x 74 x 22 mm) |
Weight | 3.75 oz (110 g) |
Click on a category to view a selection of compatible accessories with the ACR 01-0129 SmartReader Plus 8 Data Logger.
Sensor Specifications | |
Type | NTC Thermistor - 10,000 Ω at 77°F (25°C) |
Range | -40 to 158°F (-40 to 70°C) |
Accuracy | ±0.3°F over the range of 32 to 158°F (±0.2 over the range of 0 to 70°C) |
Resolution | 0.05°F (0.03°C) at 25°C Better than 0.12°F (0.07°C) between -13 and 158°F (-25 and 70°C) Better than 0.23°F (0.13°C) between -40 and -13°F (-40 and -25°C) |
General Specifications | |
Number of Channels | Eight |
Sampling Rates | User selectable rates from 25 per second to once every eight hours |
Memory Size | 32 KB 128 KB |
Software Requirements | TrendReader® Standard 2 |
PC Requirements | IBM PC or 100% compatible with at least one free serial port 2 MB of RAM memory 2 MB of hard disk space |
Operating Limits | -40 to 158°F (-40 to 70°C) and 0 to 95% RH (non-condensing) |
Sampling Methods | Continuous (First-in, first-out) Stop when full (Fill-then-stop) |
Clock Accuracy | ±2 seconds per day |
Mounting | Magnetic backing or locking eyelet |
Resolution | 12-bit (1 part in 4096) |
Battery | 3.6 V Lithium |
Case Material | Noryl® plastic |
Dimensions | 4.2 x 2.9 x 0.9" (107 x 74 x 22 mm) |
Weight | 3.75 oz (110 g) |
Click on a category to view a selection of compatible accessories with the ACR 01-0129 SmartReader Plus 8 Data Logger.