Indicates safe levels of airflow in laboratory fume hoods, this lab hood monitor measures and reports on exhaust flow in critical or controlled indoor environments, such as pharmaceutical and university laboratories. In addition, this simple go/no-go hood monitor warns users of unsafe conditions and easily retrofits to existing hoods.
Indicates safe levels of airflow in laboratory fume hoods, this lab hood monitor measures and reports on exhaust flow in critical or controlled indoor environments, such as pharmaceutical and university laboratories. In addition, this simple go/no-go hood monitor warns users of unsafe conditions and easily retrofits to existing hoods.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Monitors category for similar products.
Or let's do a search and help you find what you need:
Features
Applications
Alarm Range | 70 to 250 FPM (0.35 to 1.25 m/s) |
Field Set-Up | Single low velocity alarm set point |
Alarm Set Points | Low Repeatability: ±10% of reading or 10 FPM (0.05 m/s), whichever is greater |
Alarm Delays | 10 seconds |
Relay Output | 1 |
Remote Alarm Acknowledge | Yes |
Display (Visual) | Jumbo green LED: Normal Jumbo red LED: Alarm |
Alarm Indications | Jumbo red LED and audible alarm (85 dB at 4" [10 cm]) |
Horn Silence | Temporary and permanent |
Mounting | Surface |
Environmental Conditions | Operating temperature: 55 to 86°F (13 to 30°C), 5 to 95% RH, non-condensing Storage temperature: -40 to 150°F (-40 to 65°C), 5 to 95% RH, non-condensing |
Power Requirements | 12 ±1 V DC or 9 ±0.5 V AC |
Dimensions | 6.05 x 3.15 x 1.8" (15.4 x 8 x 4.6 cm) |
Weight | 8 oz (0.23 kg) |
Alarm Range | 70 to 250 FPM (0.35 to 1.25 m/s) |
Field Set-Up | Single low velocity alarm set point |
Alarm Set Points | Low Repeatability: ±10% of reading or 10 FPM (0.05 m/s), whichever is greater |
Alarm Delays | 10 seconds |
Relay Output | 1 |
Remote Alarm Acknowledge | Yes |
Display (Visual) | Jumbo green LED: Normal Jumbo red LED: Alarm |
Alarm Indications | Jumbo red LED and audible alarm (85 dB at 4" [10 cm]) |
Horn Silence | Temporary and permanent |
Mounting | Surface |
Environmental Conditions | Operating temperature: 55 to 86°F (13 to 30°C), 5 to 95% RH, non-condensing Storage temperature: -40 to 150°F (-40 to 65°C), 5 to 95% RH, non-condensing |
Power Requirements | 12 ±1 V DC or 9 ±0.5 V AC |
Dimensions | 6.05 x 3.15 x 1.8" (15.4 x 8 x 4.6 cm) |
Weight | 8 oz (0.23 kg) |