TED Pro Commercial Three-Phase Energy Monitoring Systems

TED Pro Commercial Three-Phase Energy Monitoring Systems

TED Pro Commercial Three-Phase Energy Monitoring Systems

State-of-the-art energy monitoring systems designed for commercial use, and suitable for three-phase systems up to 2000A. Energy use and alerts can be viewed on a computer or the Internet. Colored LEDs alert for rate-tier changes, high demand, cost or other defined parameters.

State-of-the-art energy monitoring systems designed for commercial use, and suitable for three-phase systems up to 2000A. Energy use and alerts can be viewed on a computer or the Internet. Colored LEDs alert for rate-tier changes, high demand, cost or other defined parameters.


TED Pro Commercial Series Offers

Features

  • State-of-the-art system for use in commercial or small industrial complexes
  • It is designed to work on any three-phase electrical system up to 5000A
  • Allows you to monitor and manage energy usage
  • Energy use and alerts can be presented on a computer or over the Internet
  • Colored LEDs alert you to rate-tier changes, high demand, cost or other user-defined parameters
  • Compatible with numerous energy or demand-rate billing systems, including fixed, time-of-use, step/tiered, seasonal, demand, or any combination of those mentioned
  • It also accommodates taxes, fixed charges, and fuel surcharges to accurately reflect the monthly electric bill
  • Measuring Transmitting Unit (MTU) features state-of-the-art Power Line Carrier communication (PLC)
  • The Energy Control Center (ECC) is the communication hub for the system

TED Pro MTU

The Measuring Transmitting Unit (MTU) measures the energy consumption, demand voltage, current, and power factor. It is designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It is suitable for any three-phase system up to 5000A. It has two options for data-communication between MTU and ECC: PLC or Ethernet.

The MTU is generally located at the main electrical panel and transmits the information collected over the building's existing electrical wiring, using state-of-the-art Power Line Carrier communications (PLC) to an ECC which receives and interprets the data. Multiple MTUs can be used to give individual measurement of panels or loads. For systems with solar, wind or other alternative generation, TED will provide the user consumption, generation and net usage.

TED Pro ECC

The Energy Control Center (ECC) is the communication hub for the system. It receives raw energy-use data from the MTU(s), interprets the data and calculates the current energy cost, cost today, month-to-date, and various other calculations. The ECC can be configured to communicate with display devices, computers, networks, mobile devices, thermostats, and load control devices via Ethernet, PLC, or WiFi. The TED system can be further configured to send text or e-mail alerts using TED Advisor software.

Multiple ECCs in multiple locations can be monitored via the internet using TED's proprietary Commander software.

Go further with these options:

  • Multiple MTUs can be added to separately measure various loads or generation
  • TED Spyder:
    • Mounts in, or beside the electrical panel and is connected to the MTU
    • Records detailed usage of up to 8 single or multi-phase circuits
    • These individual readings are stored in the ECC for display
    • Each TED system can support up to 4 MTUs and 4 Spyders, thus monitoring up to 36 separate, individual loads
  • Multiple systems can be used and the data aggregated at a central location
  • Communication modules (ECC includes two USNAP ports, an Ethernet and USB port):
    • WiFi modules – Allow wireless communication with a router or other WiFi-enabled device
    • ZigBee modules – Allows communication with Smart Meters, Smart Thermostats and other ZigBee- enabled devices
  • Smart Thermostats:
    • WiFi or ZigBee-based

Applications

  • Commercial
  • Industrial
  • Energy monitoring

TED Pro Commercial Specifications

Measuring Transmitting Unit (MTU)
Single-phase 2-wire or 3-wire Yes
Frequency 50/60 Hz
Maximum voltage - Phase/Phase 600V
Maximum voltage - Phase/Neutral 347V
Minimum voltage 180V
Maximum current - per phase Up to 5000A
Maximum wire size 500 MCM (23mm OD)
Operating temperature -40°C<TA>+50°C
Overall accuracy Better than ±2%
Data-Receiving Unit (ECC)
Works with single phase MTU Yes
Maximum voltage - Phase/Neutral 277V
Minimum voltage - Phase/Neutral 95V
Frequency 50/60 Hz
Operating temperature +5°C<TA<+40°C
LED Power-on: Blue
Link status: Green/ Yellow
Transmit/Receive: Green/Red
Energy-use indicator bar: Green/Yellow/Red

What's included with the TED Pro Commercial Series

  • Energy Control Center (ECC)
  • Measuring Transmitting Unit (MTU PRO)

All TED Pro packages come with interactive Footprints Software which provides real-time readings, estimated bills, voltage readings, current rate structures and more helpful information.

View a Live Demo Here

Click on a category to view a selection of compatible accessories with the TED Pro Commercial Three-Phase Energy Monitoring Systems.

TED Spyder 200-D Individual Circuit Monitoring Tool for Pro Series, 200A Spyder 200-D
Features eight solid-core current transformers that are designed to go around individual circuit conductors of 200A inside of a breaker panel. It will log data for individual circuits, appliances, systems, and motors.




TED Spyder 20 Individual Circuit Monitoring Tool for Pro Series, 20A Spyder 20
Features eight solid-core current transformers that are designed to go around individual circuit conductors of 20A inside of a breaker panel. It will log data for individual circuits, appliances, systems, and motors.




TED Spyder POP Individual Circuit Monitoring Tool for Pro Series with 20A, 60A and 200A CTs Spyder POP
Features eight solid/split-core current transformers that are designed to go around individual circuit conductors of 20A, 60A, and 200A inside of a breaker panel. It will log data for individual circuits, appliances, systems, and motors.




TED Spyder 60 Individual Circuit Monitoring Tool for Pro Series, 60A SPYDER 60
Features eight solid-corecurrent transformers that are designed to go around individual circuit conductors of 60A inside of a breaker panel. It will log data for individual circuits, appliances, systems, and motors.




TED MTU Pro Three-Phase Measuring Transmitting Unit MTU PRO
Designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It is suitable for systems that have a maximum of 600V/1200A, and services with a maximum of 400A to 1200A. It offers two options for data communication between it and the ECC: PLC or Ethernet.




TED MTU PRO-RC Measuring Transmitting Unit MTU PRO-RC
Designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It is suitable for services that have a maximum of 600V, and for 2000A or 5000A Rogowski Coils. It offers two options for data communication between it and the ECC: PLC or Ethernet.




TED CT302 Split-Core Current Transformer, 400A CT302
Ideal solution for services with aluminum conductors where a 200A CT is too small. To be used in conjunction with the MTU PRO.




TED RC5001 Rogowski Coil, 36", 5000A RC5001
Featuring a flexible 5000A Rogowski Coil that is 36 inches in length. To be used in conjunction with the MTU PRO.




Customer Reviews for the TED TED PRO

Ask a question about TED Pro Commercial Three-Phase Energy Monitoring Systems

TED Pro Commercial Series Offers

Features

  • State-of-the-art system for use in commercial or small industrial complexes
  • It is designed to work on any three-phase electrical system up to 5000A
  • Allows you to monitor and manage energy usage
  • Energy use and alerts can be presented on a computer or over the Internet
  • Colored LEDs alert you to rate-tier changes, high demand, cost or other user-defined parameters
  • Compatible with numerous energy or demand-rate billing systems, including fixed, time-of-use, step/tiered, seasonal, demand, or any combination of those mentioned
  • It also accommodates taxes, fixed charges, and fuel surcharges to accurately reflect the monthly electric bill
  • Measuring Transmitting Unit (MTU) features state-of-the-art Power Line Carrier communication (PLC)
  • The Energy Control Center (ECC) is the communication hub for the system

TED Pro MTU

The Measuring Transmitting Unit (MTU) measures the energy consumption, demand voltage, current, and power factor. It is designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It is suitable for any three-phase system up to 5000A. It has two options for data-communication between MTU and ECC: PLC or Ethernet.

The MTU is generally located at the main electrical panel and transmits the information collected over the building's existing electrical wiring, using state-of-the-art Power Line Carrier communications (PLC) to an ECC which receives and interprets the data. Multiple MTUs can be used to give individual measurement of panels or loads. For systems with solar, wind or other alternative generation, TED will provide the user consumption, generation and net usage.

TED Pro ECC

The Energy Control Center (ECC) is the communication hub for the system. It receives raw energy-use data from the MTU(s), interprets the data and calculates the current energy cost, cost today, month-to-date, and various other calculations. The ECC can be configured to communicate with display devices, computers, networks, mobile devices, thermostats, and load control devices via Ethernet, PLC, or WiFi. The TED system can be further configured to send text or e-mail alerts using TED Advisor software.

Multiple ECCs in multiple locations can be monitored via the internet using TED's proprietary Commander software.

Go further with these options:

  • Multiple MTUs can be added to separately measure various loads or generation
  • TED Spyder:
    • Mounts in, or beside the electrical panel and is connected to the MTU
    • Records detailed usage of up to 8 single or multi-phase circuits
    • These individual readings are stored in the ECC for display
    • Each TED system can support up to 4 MTUs and 4 Spyders, thus monitoring up to 36 separate, individual loads
  • Multiple systems can be used and the data aggregated at a central location
  • Communication modules (ECC includes two USNAP ports, an Ethernet and USB port):
    • WiFi modules – Allow wireless communication with a router or other WiFi-enabled device
    • ZigBee modules – Allows communication with Smart Meters, Smart Thermostats and other ZigBee- enabled devices
  • Smart Thermostats:
    • WiFi or ZigBee-based

Applications

  • Commercial
  • Industrial
  • Energy monitoring

TED Pro Commercial Specifications

Measuring Transmitting Unit (MTU)
Single-phase 2-wire or 3-wire Yes
Frequency 50/60 Hz
Maximum voltage - Phase/Phase 600V
Maximum voltage - Phase/Neutral 347V
Minimum voltage 180V
Maximum current - per phase Up to 5000A
Maximum wire size 500 MCM (23mm OD)
Operating temperature -40°C<TA>+50°C
Overall accuracy Better than ±2%
Data-Receiving Unit (ECC)
Works with single phase MTU Yes
Maximum voltage - Phase/Neutral 277V
Minimum voltage - Phase/Neutral 95V
Frequency 50/60 Hz
Operating temperature +5°C<TA<+40°C
LED Power-on: Blue
Link status: Green/ Yellow
Transmit/Receive: Green/Red
Energy-use indicator bar: Green/Yellow/Red

What's included with the TED Pro Commercial Series

  • Energy Control Center (ECC)
  • Measuring Transmitting Unit (MTU PRO)

All TED Pro packages come with interactive Footprints Software which provides real-time readings, estimated bills, voltage readings, current rate structures and more helpful information.

View a Live Demo Here

Click on a category to view a selection of compatible accessories with the TED Pro Commercial Three-Phase Energy Monitoring Systems.

TED Spyder 200-D Individual Circuit Monitoring Tool for Pro Series, 200A Spyder 200-D
Features eight solid-core current transformers that are designed to go around individual circuit conductors of 200A inside of a breaker panel. It will log data for individual circuits, appliances, systems, and motors.




TED Spyder 20 Individual Circuit Monitoring Tool for Pro Series, 20A Spyder 20
Features eight solid-core current transformers that are designed to go around individual circuit conductors of 20A inside of a breaker panel. It will log data for individual circuits, appliances, systems, and motors.




TED Spyder POP Individual Circuit Monitoring Tool for Pro Series with 20A, 60A and 200A CTs Spyder POP
Features eight solid/split-core current transformers that are designed to go around individual circuit conductors of 20A, 60A, and 200A inside of a breaker panel. It will log data for individual circuits, appliances, systems, and motors.




TED Spyder 60 Individual Circuit Monitoring Tool for Pro Series, 60A SPYDER 60
Features eight solid-corecurrent transformers that are designed to go around individual circuit conductors of 60A inside of a breaker panel. It will log data for individual circuits, appliances, systems, and motors.




TED MTU Pro Three-Phase Measuring Transmitting Unit MTU PRO
Designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It is suitable for systems that have a maximum of 600V/1200A, and services with a maximum of 400A to 1200A. It offers two options for data communication between it and the ECC: PLC or Ethernet.




TED MTU PRO-RC Measuring Transmitting Unit MTU PRO-RC
Designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It is suitable for services that have a maximum of 600V, and for 2000A or 5000A Rogowski Coils. It offers two options for data communication between it and the ECC: PLC or Ethernet.




TED CT302 Split-Core Current Transformer, 400A CT302
Ideal solution for services with aluminum conductors where a 200A CT is too small. To be used in conjunction with the MTU PRO.




TED RC5001 Rogowski Coil, 36", 5000A RC5001
Featuring a flexible 5000A Rogowski Coil that is 36 inches in length. To be used in conjunction with the MTU PRO.




Ask a question about TED Pro Commercial Three-Phase Energy Monitoring Systems

Customer Reviews for the TED TED PRO

More TED Products

Model Selection