Designed for testing and calibration of protection and control relays, this protective relay tester features a direct front panel interface that simplifies the simulation of power system phenomena. Moreover, this all-in-one solution verifies voltage, current, phase, and power transducers.
Our rentals come fully calibrated to traceable standards. Have your own instrument? We also offer calibration services for this model (CERTIRT2).
Designed for testing and calibration of protection and control relays, this protective relay tester features a direct front panel interface that simplifies the simulation of power system phenomena. Moreover, this all-in-one solution verifies voltage, current, phase, and power transducers.
Our rentals come fully calibrated to traceable standards. Have your own instrument? We also offer calibration services for this model (CERTIRT2).
This product exceeds standard shipping dimensions/weight, as such it does not qualify for free shipping. We will contact you with your shipping costs.
The ideal integrated system for testing and calibration of protection and control relays, simulation of power system phenomena, and verification of voltage, current, phase, and power transducers.
Easily test single overcurrent relays to multi-terminal end-to-end schemes with this one box. No add-ons. No hidden costs. The MTS-5100 includes all the power (VA) that you need for old electromechanical relays in each output channel to minimize connection changes, with all of the output current and voltage channels you need for modern microprocessor-based relays. Powerful productivity functions and built-in intelligence make it a simple task to perform realistic power system simulations which increases productivity and effectiveness. You can even save your test results directly from the front panel to simplify your NERC/FERC reporting requirements.
Features
Applications
State Sequencing | |
State Duration | Infinite or 0 to 9999.9999 seconds |
Control | On contact/voltage input |
Point-On-Wave | Programmable from 0 to 359 deg for Prefault to Fault1 transition |
DC Offset | Exponentially decaying, user controllable |
Time Measurement | |
Number of Timers | 5 |
Range | 0 to 99,999 seconds 0 to 99,999 cycles |
Significant Digits | 6 |
Accuracy | ±0.5 ppm of reading ±50μs |
Resolution | For times <1 second: 0.1 ms For times >1 second: 1 ms |
General Specifications | |
Ramping | AC current (each output): 0 to ±100,000 A/s AC voltage (each output): 0 to ±100,000 V/s Phase angle (each output): 0 to ±9000.0 °/s Frequency (each frequency source): 0 to ±20.00 Hz/s |
Sequence Of Events Recording | Resolution: 0.1 ms |
Waveform Capture | Resolution: ±0.2 Vdc for signal levels ±300 Vdc |
Display Of Relaying Quantities | V0, V1, V2 I0, I1, I2 Impedance (positive sequence 3-phase, phase-phase or phase-ground) V/Hz, % unbalance, power, impedance ratios |
Automatic Control | RS-232 and Ethernet communication interfaces |
Communication Interfaces | USB 2.0, IEC-61850 / GOOSE, HTTP, FTP, ASCII commands |
Environmental Conditions | Operating temperature: 14 to 122°F (-10 to 50°C) Relative humidity: 5% to 90%, non-condensing Storage temperature: -22 to 158°F (-30 to 70°C) |
Dimensions | 18.9 x 14.5 x 11.7" (48 x 36.8 x 29.7 cm) |
Weight | 49 lbs (22.2 kg) |
State Sequencing | |
State Duration | Infinite or 0 to 9999.9999 seconds |
Control | On contact/voltage input |
Point-On-Wave | Programmable from 0 to 359 deg for Prefault to Fault1 transition |
DC Offset | Exponentially decaying, user controllable |
Time Measurement | |
Number of Timers | 5 |
Range | 0 to 99,999 seconds 0 to 99,999 cycles |
Significant Digits | 6 |
Accuracy | ±0.5 ppm of reading ±50μs |
Resolution | For times <1 second: 0.1 ms For times >1 second: 1 ms |
General Specifications | |
Ramping | AC current (each output): 0 to ±100,000 A/s AC voltage (each output): 0 to ±100,000 V/s Phase angle (each output): 0 to ±9000.0 °/s Frequency (each frequency source): 0 to ±20.00 Hz/s |
Sequence Of Events Recording | Resolution: 0.1 ms |
Waveform Capture | Resolution: ±0.2 Vdc for signal levels ±300 Vdc |
Display Of Relaying Quantities | V0, V1, V2 I0, I1, I2 Impedance (positive sequence 3-phase, phase-phase or phase-ground) V/Hz, % unbalance, power, impedance ratios |
Automatic Control | RS-232 and Ethernet communication interfaces |
Communication Interfaces | USB 2.0, IEC-61850 / GOOSE, HTTP, FTP, ASCII commands |
Environmental Conditions | Operating temperature: 14 to 122°F (-10 to 50°C) Relative humidity: 5% to 90%, non-condensing Storage temperature: -22 to 158°F (-30 to 70°C) |
Dimensions | 18.9 x 14.5 x 11.7" (48 x 36.8 x 29.7 cm) |
Weight | 49 lbs (22.2 kg) |