Both portable and reliable, this multifunction vibration screening tool provides quantifiable information on the bearing and overall health of motors and other rotating equipment. Ideal for frontline mechanical troubleshooting teams, this vibration screening tool allows for confident and quick maintenance decisions.
Both portable and reliable, this multifunction vibration screening tool provides quantifiable information on the bearing and overall health of motors and other rotating equipment. Ideal for frontline mechanical troubleshooting teams, this vibration screening tool allows for confident and quick maintenance decisions.
Features
Applications
Infrared cameras, also called thermal imagers, are useful for troubleshooting motor problems as well as for monitoring motor condition for preventative maintenance in power generation, manufacturing and commercial plants. Thermal images of motors reveal their operating condition as indicated by surface temperature. Such condition monitoring is important as a way to avert many unexpected motor malfunctions in systems that are critical to manufacturing. The onset of motor failures can often be detected by a variety of techniques, including vibration, ultrasound and thermal imaging.
In this article, we cover why use thermal imaging and what to scan, as well as some notes on what to look for, including shaft misalignment.
Read the ArticleVibration Meter | |
Low Frequency Range (overall measurement) | 10 to 1,000 Hz |
High Frequency Range (CF+ measurement) | 4,000 to 20,000 Hz |
Severity Levels | Good, satisfactory, unsatisfactory, unacceptable |
Vibration Limit | 50g peak (100g peak-peak) |
A/D Converter | 16-bit |
Signal to Noise Ratio | 80 dB |
Sampling Rate | Low frequency: 20,000 Hz High frequency: 80,000 Hz |
Real Time Clock Backup | Coin battery |
Sensor | |
Sensitivity | 100mV g ±10% |
Measurement Range | 0.01 to 50g |
Low Frequency Range (overall measurement) | 10 to 1,000 Hz |
High Frequency Range | 4,000 to 20,000 Hz |
Resolution | 0.01g |
Accuracy | At 100Hz ±5% of measured value |
Amplitude Units | |
Acceleration | g, m/sec2 |
Velocity | in/sec, mm/sec |
Displacement | mils, mm |
IR Temperature Measurements | |
Range | -20 to 200°C (-4 to 392°F) |
Accuracy | ±2°C (4°F) |
Focal Length | Fixed, at ~3.8 cm (1.5 in) |
External Sensor | |
Frequency Range | 10 to 1,000 Hz |
Bias Voltage (to supply power) |
20V DC to 22V DC |
Bias Current (to supply power) | Maximum 5 mA |
Firmware | |
Calibration | Factory calibration required |
External Interfaces | USB 2.0 (full speed) communication |
Data Capacity | Database on internal flash memory |
Upgrade | Through USB |
Memory | Up to 3500 measurements |
Radiated Emission | |
Electrostatic Discharge: Burst | Standard EN 61000-4-2 |
Electromagnetic Interference | Standard EN 61000-4-3 |
RE | Standard CISPR 11, Class A |
Environmental | |
Temperature | Operating: -4 to 122°F (-20 to 50°C) Storage: -22 to 176°F (-30 to 80°C) |
Operating Humidity | 10 to 95% RH (non-condensing) |
Operating/Storage Altitude | Seal level to 10,000' (3048 m) |
IP Rating | IP54 |
Vibration Limit | 500 g peak |
Drop Test | 3.2' (1 m) |
General Specifications | |
Battery | Type: 2 x AA alkaline or lithium-ion 2 V DC Life: 250 measurements |
Dimensions | 10.13 x 6.38 x 3.875" (25.72 x 16.19 x 9.84 cm) |
Weight | 2.55 lbs (1.16 kg) |
Click on a category to view a selection of compatible accessories with the Rental - Fluke 805 Vibration Meter .
Vibration Meter | |
Low Frequency Range (overall measurement) | 10 to 1,000 Hz |
High Frequency Range (CF+ measurement) | 4,000 to 20,000 Hz |
Severity Levels | Good, satisfactory, unsatisfactory, unacceptable |
Vibration Limit | 50g peak (100g peak-peak) |
A/D Converter | 16-bit |
Signal to Noise Ratio | 80 dB |
Sampling Rate | Low frequency: 20,000 Hz High frequency: 80,000 Hz |
Real Time Clock Backup | Coin battery |
Sensor | |
Sensitivity | 100mV g ±10% |
Measurement Range | 0.01 to 50g |
Low Frequency Range (overall measurement) | 10 to 1,000 Hz |
High Frequency Range | 4,000 to 20,000 Hz |
Resolution | 0.01g |
Accuracy | At 100Hz ±5% of measured value |
Amplitude Units | |
Acceleration | g, m/sec2 |
Velocity | in/sec, mm/sec |
Displacement | mils, mm |
IR Temperature Measurements | |
Range | -20 to 200°C (-4 to 392°F) |
Accuracy | ±2°C (4°F) |
Focal Length | Fixed, at ~3.8 cm (1.5 in) |
External Sensor | |
Frequency Range | 10 to 1,000 Hz |
Bias Voltage (to supply power) |
20V DC to 22V DC |
Bias Current (to supply power) | Maximum 5 mA |
Firmware | |
Calibration | Factory calibration required |
External Interfaces | USB 2.0 (full speed) communication |
Data Capacity | Database on internal flash memory |
Upgrade | Through USB |
Memory | Up to 3500 measurements |
Radiated Emission | |
Electrostatic Discharge: Burst | Standard EN 61000-4-2 |
Electromagnetic Interference | Standard EN 61000-4-3 |
RE | Standard CISPR 11, Class A |
Environmental | |
Temperature | Operating: -4 to 122°F (-20 to 50°C) Storage: -22 to 176°F (-30 to 80°C) |
Operating Humidity | 10 to 95% RH (non-condensing) |
Operating/Storage Altitude | Seal level to 10,000' (3048 m) |
IP Rating | IP54 |
Vibration Limit | 500 g peak |
Drop Test | 3.2' (1 m) |
General Specifications | |
Battery | Type: 2 x AA alkaline or lithium-ion 2 V DC Life: 250 measurements |
Dimensions | 10.13 x 6.38 x 3.875" (25.72 x 16.19 x 9.84 cm) |
Weight | 2.55 lbs (1.16 kg) |