Ideal for high-temperature industrial environments whether it's power utility, metal refining and smelting, glass, cement or petrochemical environments.
Ideal for high-temperature industrial environments whether it's power utility, metal refining and smelting, glass, cement or petrochemical environments.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
This high-temperature infrared thermometer is built for use in high-temperature industrial environments. It has a straight-forward user interface and soft-key menus, making even complex measurements easier. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.
Features
Applications
| Infrared Measurements | |
| Temperature Range | -22 to 1652°F (-30 to 900°C) |
| IR Accuracy (calibration geometry with ambient temperature 23°C ±2°C) | ≥32°F: ±2°F or ±1% of the reading, whichever is greater ≥14°F to <32°F: ±4°F<br> <14°F: ±6°F<br> ≥0°C: ±1°C or ±1 % of the reading, whichever is greater ≥-10°C to <0°C: ±2°C<br> <-10°C:±3°C |
| IR Repeatability | ±0.5% of reading or ±1°F (±0.5°C), whichever is greater |
| Display Resolution | 0.1°F/0.1°C |
| Distance:Spot | 60:1 (calculated at 90% energy) |
| Minimum Spot Size | 0.75" (19 mm) |
| Laser Sighting | Offset dual laser, output <1 mW |
| Spectral Response | 8 µm to 14 µm |
| Response Time (95%) | <500 ms |
| Emissivity | Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials |
| Contact Measurements | |
| K-Type Thermocouple Input Temperature Range | -454 to 2501°F (-270 to 1372°C) |
| K-Type Thermocouple Input Accuracy | <-40°F: ±(2°F + 0.2°/1°F)<br> ≥-40°F: ±1% or 2°F, whichever is greater <-40°C: ±(1°C + 0.2°/1°C)<br> ≥-40°C: ±1% or 1°C, whichever is greater |
| K-Type Thermocouple | 0.1°F/0.1°C |
| K-Type Thermocouple Repeatability | ±0.5% of reading or ±1°F (±0.5°C), whichever is greater |
| Measurement Options | |
| Hi/Low Alarms | Audible and two-color visual |
| Min/Max/Avg/Dif | Yes |
| Switchable Celsius and Fahrenheit | Yes |
| Backlight | Two levels, normal and extra bright for darker environments |
| Probe Input | K-type thermocouple simultaneous display of probe and IR temperature |
| Trigger Lock | Yes |
| Data Storage | 99 points |
| Display | Dot matrix 98 x 96 pixels with function menus |
| Communication | USB 2.0 |
| K-Type Thermocouple Specifications | |
| Measurement Range (Bead Probe) | -40 to 500°F (-40 to 260°C) |
| Accuracy | ±2.0°F (±1.1°C) from 32 to 500°F (0 to 260°C) Typically within 2.0°F (1.1°C) from -40 to 32°F (-40 to 0°C) |
| Cable Length | 40" (1 m) K-type thermocouple cable with standard miniature thermocouple connector and bead termination |
| General Specifications | |
| Safety and Compliance | IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009 |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) |
| Relative Humidity | 10 to 90% RH non-condensing up to 86°F (30°C) |
| Operating Altitude | 2000 meters above mean sea level |
| Weight | 0.7099 lbs (0.322 kg) |
| Power | 2 x AA batteries |
| Battery Life | 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on) |
Click on a category to view a selection of compatible accessories with the Rental - Fluke 572-2 High Temperature Infrared Thermometer, -22 to 1652-F.
| Infrared Measurements | |
| Temperature Range | -22 to 1652°F (-30 to 900°C) |
| IR Accuracy (calibration geometry with ambient temperature 23°C ±2°C) | ≥32°F: ±2°F or ±1% of the reading, whichever is greater ≥14°F to <32°F: ±4°F<br> <14°F: ±6°F<br> ≥0°C: ±1°C or ±1 % of the reading, whichever is greater ≥-10°C to <0°C: ±2°C<br> <-10°C:±3°C |
| IR Repeatability | ±0.5% of reading or ±1°F (±0.5°C), whichever is greater |
| Display Resolution | 0.1°F/0.1°C |
| Distance:Spot | 60:1 (calculated at 90% energy) |
| Minimum Spot Size | 0.75" (19 mm) |
| Laser Sighting | Offset dual laser, output <1 mW |
| Spectral Response | 8 µm to 14 µm |
| Response Time (95%) | <500 ms |
| Emissivity | Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials |
| Contact Measurements | |
| K-Type Thermocouple Input Temperature Range | -454 to 2501°F (-270 to 1372°C) |
| K-Type Thermocouple Input Accuracy | <-40°F: ±(2°F + 0.2°/1°F)<br> ≥-40°F: ±1% or 2°F, whichever is greater <-40°C: ±(1°C + 0.2°/1°C)<br> ≥-40°C: ±1% or 1°C, whichever is greater |
| K-Type Thermocouple | 0.1°F/0.1°C |
| K-Type Thermocouple Repeatability | ±0.5% of reading or ±1°F (±0.5°C), whichever is greater |
| Measurement Options | |
| Hi/Low Alarms | Audible and two-color visual |
| Min/Max/Avg/Dif | Yes |
| Switchable Celsius and Fahrenheit | Yes |
| Backlight | Two levels, normal and extra bright for darker environments |
| Probe Input | K-type thermocouple simultaneous display of probe and IR temperature |
| Trigger Lock | Yes |
| Data Storage | 99 points |
| Display | Dot matrix 98 x 96 pixels with function menus |
| Communication | USB 2.0 |
| K-Type Thermocouple Specifications | |
| Measurement Range (Bead Probe) | -40 to 500°F (-40 to 260°C) |
| Accuracy | ±2.0°F (±1.1°C) from 32 to 500°F (0 to 260°C) Typically within 2.0°F (1.1°C) from -40 to 32°F (-40 to 0°C) |
| Cable Length | 40" (1 m) K-type thermocouple cable with standard miniature thermocouple connector and bead termination |
| General Specifications | |
| Safety and Compliance | IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009 |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage Temperature | -4 to 140°F (-20 to 60°C) |
| Relative Humidity | 10 to 90% RH non-condensing up to 86°F (30°C) |
| Operating Altitude | 2000 meters above mean sea level |
| Weight | 0.7099 lbs (0.322 kg) |
| Power | 2 x AA batteries |
| Battery Life | 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on) |
Click on a category to view a selection of compatible accessories with the Rental - Fluke 572-2 High Temperature Infrared Thermometer, -22 to 1652-F.