Megger PAT350-UK Portable Appliance Tester, Flash Test Functions, 110V and 230V

Model: PAT350-UK | Order No: 1000-743

Megger PAT350-UK Portable Appliance Tester, Flash Test Functions, 110V and 230V

Model: PAT350-UK | Order No: 1000-743

Portable appliance tester for testing the safety of portable electrical equipment to meet health and safety regulations. The fully featured tester with dedicated test buttons for direct access to tests. Designed for customers who do not require the complexity of a fully configurable database of clients and results within the tester but do need a complete range of functions to allow automatic or manual testing of the widest range of electrical assets. Simply push-button operation makes this tester fast and intuitive to use.

Portable appliance tester for testing the safety of portable electrical equipment to meet health and safety regulations. The fully featured tester with dedicated test buttons for direct access to tests. Designed for customers who do not require the complexity of a fully configurable database of clients and results within the tester but do need a complete range of functions to allow automatic or manual testing of the widest range of electrical assets. Simply push-button operation makes this tester fast and intuitive to use.

Regular Price $2190.00 CAD
Availability 2 to 3 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 1000-743 Portable Appliance Tester

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 1000-743 Portable Appliance Tester

Megger PAT350-UK Offers

The PAT350 has additional flash test functions and is the ideal tester for high throughput requirements if you work in a tool hire company or a service center.

Features

  • Simple manual for automatic testing
  • Bond testing at 25 A, 10 A and 200 mA
  • Differential, touch and substitute leakage testing
  • Full color display
  • Tests portable RCDs and extension leads
  • Pre-set test sequences for Class I, Class II and extension leads
  • Flash testing 1.5 kV and 3 kV
  • Tests to DIN VDE 0701-0702

Applications

High current bond testing and flash-test capability for use in environments such as manufacturing, production or tool-hire shops.

All regulatory test requirements are supported, including Class I and Class II, IEC power leads, extension leads and full tests for portable RCDs. An automatic mode is available for class I and Class II testing. In automatic mode, the tests proceed sequentially through bond, insulation and operation, indicating a pass or fail at each test. If a fail occurs, testing is stopped. When manual testing, each test is preceded by a selection screen where the test parameters are selected, such as bond test current, insulation test voltage or leakage test type. These diagnostic buttons provide direct access to any test individually, allowing single tests to be performed following repair or a suspect result.

Megger PAT350-UK Specifications

Open Circuit Voltage
10 A Bond Test Current 10 A rms ±20% ± 0.5A into 0.1 Ω
Earth Bond Resistance Accuracy ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
Earth Bond Resistance Resolution 10 mΩ (0 to 1.99 Ω)
Display Range 0 to 1.99 Ω
Bond Test Nulling Up to 1.00 Ω
Adjustable Test Duration User selectable from 1 sec to 20 sec
Continuity Test Voltage 4.0 V d.c. -0% +10% (open circuit)
Continuity Test Current 200 mA -0% +10% ±5 mA (into 2 Ω load)
Continuity Resistance Accuracy ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
Continuity Resistance Resolution 10 mΩ (1 to 19.99 Ω)
Continuity Test Nulling up to up to 9.99 Ω
Test Voltage 3.3 V
Operating Temperature 10 to +50 ºC
Storage Temperature -20 to +60 ºC
Weight 5.0 kg
Dimensions 175 mm (H) x 320 mm (D) x 250 mm (W)
Click here for complete specifications on the Megger PAT350-UK

What's included with the Megger PAT350-UK

  • Megger PAT350-UK Portable Appliance Tester
  • Printed Quick Start Guide
  • Full User Guide on CD
  • Calibration Certificate
  • Continuity/Earth Bond Lead + Probe
  • Extension Lead Adapter
  • Flash Test Lead 3.0 Kv 3.5 mA
  • Carry Case with Lead/Document Pouch
  • Screen Protector

Ask a question about Megger PAT350-UK Portable Appliance Tester, Flash Test Functions, 110V and 230V

Customer Reviews for the Megger PAT350-UK

Megger PAT350-UK Offers

The PAT350 has additional flash test functions and is the ideal tester for high throughput requirements if you work in a tool hire company or a service center.

Features

  • Simple manual for automatic testing
  • Bond testing at 25 A, 10 A and 200 mA
  • Differential, touch and substitute leakage testing
  • Full color display
  • Tests portable RCDs and extension leads
  • Pre-set test sequences for Class I, Class II and extension leads
  • Flash testing 1.5 kV and 3 kV
  • Tests to DIN VDE 0701-0702

Applications

High current bond testing and flash-test capability for use in environments such as manufacturing, production or tool-hire shops.

All regulatory test requirements are supported, including Class I and Class II, IEC power leads, extension leads and full tests for portable RCDs. An automatic mode is available for class I and Class II testing. In automatic mode, the tests proceed sequentially through bond, insulation and operation, indicating a pass or fail at each test. If a fail occurs, testing is stopped. When manual testing, each test is preceded by a selection screen where the test parameters are selected, such as bond test current, insulation test voltage or leakage test type. These diagnostic buttons provide direct access to any test individually, allowing single tests to be performed following repair or a suspect result.

Megger PAT350-UK Specifications

Open Circuit Voltage
10 A Bond Test Current 10 A rms ±20% ± 0.5A into 0.1 Ω
Earth Bond Resistance Accuracy ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
Earth Bond Resistance Resolution 10 mΩ (0 to 1.99 Ω)
Display Range 0 to 1.99 Ω
Bond Test Nulling Up to 1.00 Ω
Adjustable Test Duration User selectable from 1 sec to 20 sec
Continuity Test Voltage 4.0 V d.c. -0% +10% (open circuit)
Continuity Test Current 200 mA -0% +10% ±5 mA (into 2 Ω load)
Continuity Resistance Accuracy ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
Continuity Resistance Resolution 10 mΩ (1 to 19.99 Ω)
Continuity Test Nulling up to up to 9.99 Ω
Test Voltage 3.3 V
Operating Temperature 10 to +50 ºC
Storage Temperature -20 to +60 ºC
Weight 5.0 kg
Dimensions 175 mm (H) x 320 mm (D) x 250 mm (W)
Click here for complete specifications on the Megger PAT350-UK

What's included with the Megger PAT350-UK

  • Megger PAT350-UK Portable Appliance Tester
  • Printed Quick Start Guide
  • Full User Guide on CD
  • Calibration Certificate
  • Continuity/Earth Bond Lead + Probe
  • Extension Lead Adapter
  • Flash Test Lead 3.0 Kv 3.5 mA
  • Carry Case with Lead/Document Pouch
  • Screen Protector