Megger DET4TC2-KIT Contractor Series Earth/Ground Resistance Tester

Model: DET4TC2-KIT | Order No: 1000-404

Megger DET4TC2-KIT Contractor Series Earth/Ground Resistance Tester

Model: DET4TC2-KIT | Order No: 1000-404

4-Terminal ground testing instrument, rated to IP54, making it truly an outdoor instrument. Designed to be easy to use and can measure resistance from 0.01 ohms to 200 kilohms, a key capability for soil resistivity testing. For accurate testing in noisy environments, the instruments are capable of rejecting noise up to 40 V peak to peak. Featuring ART testing capabilities a function so that on-site grounds can be tested separately without having to remove the utility connection.

4-Terminal ground testing instrument, rated to IP54, making it truly an outdoor instrument. Designed to be easy to use and can measure resistance from 0.01 ohms to 200 kilohms, a key capability for soil resistivity testing. For accurate testing in noisy environments, the instruments are capable of rejecting noise up to 40 V peak to peak. Featuring ART testing capabilities a function so that on-site grounds can be tested separately without having to remove the utility connection.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Megger DET4T2 Series 4-Terminal Digital Ground Testers-

Megger DET4T2 Series 4-Terminal Digital Ground Testers

Model: DET4TC2 | Order No: DET4TC2 Series

Unstoppable with a wide range of capabilities, this ground testing instrument family is perfect for greater testing flexibility. From stakeless capabilities to Attached Rod Technique (ART), everything you need for proper ground testing is at your disposal with practical accessories to improve performance.


Not what you're looking for? Let’s do a search and help you find what you need.


Megger DET4TC2-KIT Offers

Features

  • Stakeless testing capability, which allows the operator to use the instrument like a clamp-on tester in applications where the method is viable
  • Attached rod technique capability, which allows fall of potential testing without the need to disconnect the ground rod
  • Multiple, user selectable test frequencies allows the operator to find the most effective frequency for making the measurement
  • 200,000 ohm measurement range provides the ability to measure the resistivity of any type of soil
  • User selectable test frequencies allows the operator to find the most effective frequency for making the measurement
  • Microprocessor control for improved error detection
  • Clear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time
  • Rugged, waterproof case for IP54 makes the units truly outdoor instruments
  • Backlit LCD allows for testing in dark environments
  • Noise rejection to 40 V pk to pk allows accurate testing in noisy environments
  • Testing kits and certificates supplied - everything needed to start testing immediately
  • Accuracy of 2% of reading enhances reliability of measurements
  • Voltmeter function included allows you to measure the ground voltage and enhances operator safety
  • CAT IV 100V provides increased operator safety

Stakeless (Clamp-on) Testing


The DET4TC and DET4TCR2 include stakeless, or clamp-on testing capability. In effect, these models can be operated in the same way as a clamp-on ground under test and drive test probes un certain ground system testing applications. this method is also useful when there us insufficient space to perform a classic fall-of-potential measurement. In addition the units can be used to measure ground leakage or phase current.

the user simply clamps the optional ICLAMP and VCLAMP around the ground under the test in the manner prescribed in the operator's manual and takes the reading. A defined test voltage is injected into the system using the VCLAMP, including a current, I, to flow and be measured by the ICLAMP. The instrument then calculates the approximate resistance of the ground under test.

The stakeless method is subject tot the same limitations faced by the traditional clamp-on ground tester. It is effective only in situations where multiple grounds in parallel and cannot be proofed like a fall-of-potential test. In situations where the stakeless method reading is questionable, a full fall-of potential test is recommended. The advantage of the DET4TC2 and DET4TCR2 is that the units include both test methods in a single instrument, making them the worst versatile units available.


Applications

Proper grounding provides many varied benefits to both people and facilities. It lessens the chance of injury due to faulty installation, reduces the likelihood of damage from lightning strikes and induced voltages, improves the performance of a computer, communication and other sensitive equipment and protects against static electricity from friction. Over time, ground systems can degrade or become ineffective. Corrosion and weather influences exert mechanical strain on ground rods and cause metallic corrosion. Catastrophic events like lightning strikes or large fault currents can cause instant degradation. In addition, soil resistivity can change over time due to environment damage, disruption in the performance of sensitive equipment and heat build-up on a single piece of electrical equipment.

The risks from ground system deterioration include potentially deadly electrical shock situations, plant-wide equipment damage, disruption in the performance of sensitivity equipment and heat build-up on a single piece of electrical equipment.

The maintenance of an adequate low resistance ground connection is essential to both the protection and performance of any electrical system. Ground testing should be performed both upon installation, to meet design specification, and periodically thereafter in order to maintain service. All Megger models can also perform bonding tests (using an AC signal), to determine that adequate connection has been made from equipment to the grounding system, and can perform soil resistivity tests. This additional function can be used in prospecting, locating, and designing new grounding electrodes and systems. Furthermore, the addition of built-in current clamp capability enables fall of potential testing of attached grounds (ART) without lifting the utility connection and the addition of voltage clamp technology enables stakeless testing from the same instrument.

Grounding electrodes from simple to complex systems can be tested, including:

  • Primary and secondary electrical grounding systems
  • Utility pole grounds
  • Lightning protection systems
  • Residential grounds
  • Machinery safety grounds
  • Computer and communication system grounds
  • EMI/RF system grounds
  • Antenna and pedestal grounds
  • CATV system grounds

Megger DET4TC2-KIT Specifications

Resistance range 0.01Ω to 200kΩ auto ranging
Analog model 2.5% of scale length
Digital models 2P measurements 2% ±3 digits, 3P measurements 2% ±3 digits, 4P measurements 2% ±3 digits, ART measurements 5% ±3 digits, Stakeless measurements 7% ±3 digits
Maximum probe resistance Rp limit: 100k½ (50V output voltage), Rc limit: 100k½ (50V output voltage), Limits reduced to 50k½ for 25V output voltage, Limits reduced to 5k½ for 0.01 ½ resolution
Earth voltage range 0-100V
Earth voltage accuracy 2% ±2 V
2-wire test Yes, all models
3-wire test yes, all models
4-wire test DET4TD, DET4TC2, DET4TCR2
Ground current range (with current measuring clamp) 0.5mA to 19.9A
Ground current accuracy 5% ±3 digits
Display LCD (moving coil meter for analog model)
Test frequency 128 Hz
Test voltage 25 V or 50 V, user selectable (factory setting 50 V)
Test current 450 micro-amps at 25 V or 50 V (selectable), 4.5mA at 25 V
Noise rejection 40V pk to pk
Battery type 8 1.5 V AA cells
Battery life 3 hours, 700 consecutive tests
Safety EN61010-1 CAT IV 100 V
Dimensions 8 x 5.7 x 3.2 in. (203 x 148 x 78 mm)
Weight 2.2 lb (1 kg)

What's included with the Megger DET4TC2-KIT

  • Megger DET4TC2-KIT Contractor Series Earth/Ground Resistance Tester
  • Hard Carry Case
  • 4 Right-Angle Terminal Adapters
  • Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes
  • Field Calibrator
  • ICLAMP and VCLAMP
  • Earth/Ground Kit, C/N 6320-245
  • Alkaline Batteries

Click on a category to view a selection of compatible accessories with the Megger DET4TC2-KIT Contractor Series Earth/Ground Resistance Tester.

Megger 1000-531 Spare Mains Charger 1000-531
Used to recharge earth tester batteries. It is compatible with earth testers in the DET3TX and DET4TX ranges.




Megger 1000-528 Carrying Case for DET3 and DET4 1000-528
Hard case with a protective, blow-moulded design; compatible with the DET3 and DET4 Earth Testers. Protects and stores an earth tester with its accessories.




Megger 1000-435 Calibration Check Box for DET3T and DET4T Series, 25 Ohms 1000-435
The 1000-435 Calibration Check Box is used to calibrate a Megger DET3T or DET4T ground resistance meter (sold separately). The box increases the accuracy of a ground resistance meter, calibrating the resistance up to 25 ohms.




Megger 1000-526 4-Terminal Lead Set for Model DET4TD 1000-526
The 1000-526 4-wire lead set serves as a replacement for the DET4T series of ground resistance testers. The test lead set includes one 49 ft. (15 m) long lead, two 33 ft. (10 m) long leads, and one 10 ft. (3 m) long test lead.




Ask a question about Megger DET4TC2-KIT Contractor Series Earth/Ground Resistance Tester

Customer Reviews for the Megger DET4TC2-KIT

Megger DET4TC2-KIT Offers

Features

  • Stakeless testing capability, which allows the operator to use the instrument like a clamp-on tester in applications where the method is viable
  • Attached rod technique capability, which allows fall of potential testing without the need to disconnect the ground rod
  • Multiple, user selectable test frequencies allows the operator to find the most effective frequency for making the measurement
  • 200,000 ohm measurement range provides the ability to measure the resistivity of any type of soil
  • User selectable test frequencies allows the operator to find the most effective frequency for making the measurement
  • Microprocessor control for improved error detection
  • Clear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time
  • Rugged, waterproof case for IP54 makes the units truly outdoor instruments
  • Backlit LCD allows for testing in dark environments
  • Noise rejection to 40 V pk to pk allows accurate testing in noisy environments
  • Testing kits and certificates supplied - everything needed to start testing immediately
  • Accuracy of 2% of reading enhances reliability of measurements
  • Voltmeter function included allows you to measure the ground voltage and enhances operator safety
  • CAT IV 100V provides increased operator safety

Stakeless (Clamp-on) Testing


The DET4TC and DET4TCR2 include stakeless, or clamp-on testing capability. In effect, these models can be operated in the same way as a clamp-on ground under test and drive test probes un certain ground system testing applications. this method is also useful when there us insufficient space to perform a classic fall-of-potential measurement. In addition the units can be used to measure ground leakage or phase current.

the user simply clamps the optional ICLAMP and VCLAMP around the ground under the test in the manner prescribed in the operator's manual and takes the reading. A defined test voltage is injected into the system using the VCLAMP, including a current, I, to flow and be measured by the ICLAMP. The instrument then calculates the approximate resistance of the ground under test.

The stakeless method is subject tot the same limitations faced by the traditional clamp-on ground tester. It is effective only in situations where multiple grounds in parallel and cannot be proofed like a fall-of-potential test. In situations where the stakeless method reading is questionable, a full fall-of potential test is recommended. The advantage of the DET4TC2 and DET4TCR2 is that the units include both test methods in a single instrument, making them the worst versatile units available.


Applications

Proper grounding provides many varied benefits to both people and facilities. It lessens the chance of injury due to faulty installation, reduces the likelihood of damage from lightning strikes and induced voltages, improves the performance of a computer, communication and other sensitive equipment and protects against static electricity from friction. Over time, ground systems can degrade or become ineffective. Corrosion and weather influences exert mechanical strain on ground rods and cause metallic corrosion. Catastrophic events like lightning strikes or large fault currents can cause instant degradation. In addition, soil resistivity can change over time due to environment damage, disruption in the performance of sensitive equipment and heat build-up on a single piece of electrical equipment.

The risks from ground system deterioration include potentially deadly electrical shock situations, plant-wide equipment damage, disruption in the performance of sensitivity equipment and heat build-up on a single piece of electrical equipment.

The maintenance of an adequate low resistance ground connection is essential to both the protection and performance of any electrical system. Ground testing should be performed both upon installation, to meet design specification, and periodically thereafter in order to maintain service. All Megger models can also perform bonding tests (using an AC signal), to determine that adequate connection has been made from equipment to the grounding system, and can perform soil resistivity tests. This additional function can be used in prospecting, locating, and designing new grounding electrodes and systems. Furthermore, the addition of built-in current clamp capability enables fall of potential testing of attached grounds (ART) without lifting the utility connection and the addition of voltage clamp technology enables stakeless testing from the same instrument.

Grounding electrodes from simple to complex systems can be tested, including:

  • Primary and secondary electrical grounding systems
  • Utility pole grounds
  • Lightning protection systems
  • Residential grounds
  • Machinery safety grounds
  • Computer and communication system grounds
  • EMI/RF system grounds
  • Antenna and pedestal grounds
  • CATV system grounds

Megger DET4TC2-KIT Specifications

Resistance range 0.01Ω to 200kΩ auto ranging
Analog model 2.5% of scale length
Digital models 2P measurements 2% ±3 digits, 3P measurements 2% ±3 digits, 4P measurements 2% ±3 digits, ART measurements 5% ±3 digits, Stakeless measurements 7% ±3 digits
Maximum probe resistance Rp limit: 100k½ (50V output voltage), Rc limit: 100k½ (50V output voltage), Limits reduced to 50k½ for 25V output voltage, Limits reduced to 5k½ for 0.01 ½ resolution
Earth voltage range 0-100V
Earth voltage accuracy 2% ±2 V
2-wire test Yes, all models
3-wire test yes, all models
4-wire test DET4TD, DET4TC2, DET4TCR2
Ground current range (with current measuring clamp) 0.5mA to 19.9A
Ground current accuracy 5% ±3 digits
Display LCD (moving coil meter for analog model)
Test frequency 128 Hz
Test voltage 25 V or 50 V, user selectable (factory setting 50 V)
Test current 450 micro-amps at 25 V or 50 V (selectable), 4.5mA at 25 V
Noise rejection 40V pk to pk
Battery type 8 1.5 V AA cells
Battery life 3 hours, 700 consecutive tests
Safety EN61010-1 CAT IV 100 V
Dimensions 8 x 5.7 x 3.2 in. (203 x 148 x 78 mm)
Weight 2.2 lb (1 kg)

What's included with the Megger DET4TC2-KIT

  • Megger DET4TC2-KIT Contractor Series Earth/Ground Resistance Tester
  • Hard Carry Case
  • 4 Right-Angle Terminal Adapters
  • Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes
  • Field Calibrator
  • ICLAMP and VCLAMP
  • Earth/Ground Kit, C/N 6320-245
  • Alkaline Batteries

Click on a category to view a selection of compatible accessories with the Megger DET4TC2-KIT Contractor Series Earth/Ground Resistance Tester.

Megger 1000-531 Spare Mains Charger 1000-531
Used to recharge earth tester batteries. It is compatible with earth testers in the DET3TX and DET4TX ranges.




Megger 1000-528 Carrying Case for DET3 and DET4 1000-528
Hard case with a protective, blow-moulded design; compatible with the DET3 and DET4 Earth Testers. Protects and stores an earth tester with its accessories.




Megger 1000-435 Calibration Check Box for DET3T and DET4T Series, 25 Ohms 1000-435
The 1000-435 Calibration Check Box is used to calibrate a Megger DET3T or DET4T ground resistance meter (sold separately). The box increases the accuracy of a ground resistance meter, calibrating the resistance up to 25 ohms.




Megger 1000-526 4-Terminal Lead Set for Model DET4TD 1000-526
The 1000-526 4-wire lead set serves as a replacement for the DET4T series of ground resistance testers. The test lead set includes one 49 ft. (15 m) long lead, two 33 ft. (10 m) long leads, and one 10 ft. (3 m) long test lead.




Ask a question about Megger DET4TC2-KIT Contractor Series Earth/Ground Resistance Tester

Customer Reviews for the Megger DET4TC2-KIT

More Megger Products

How to Effectively Protect and Maintain Wind Turbines